The text of a manual · part 4 of 38
Trakker Antares 2400 Family System Manual: Chapter 2 - Configuring and Managing the Terminals, pages 31 to 39
Pages 31 to 39 of 362, from Trakker Antares 2400 Family System Manual
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2410, Intermec 2415, Intermec 2435 and Intermec 2475
Page 31
2
Configuring and Managing the Terminals
This chapter describes the different methods you can use to configure the Trakker Antares® terminals and covers these topics: • Overview of how to configure the terminals • Configuring the terminal by scanning bar code labels • Configuring the terminal through the serial port • Configuring the terminal through the network • Configuring the terminal with the clone application • Transferring files and data in a TCP/IP direct connect network • Saving configuration changes in flash memory • Restoring the terminal’s default configuration • Upgrading the terminal • Managing your terminals with Wavelink Avalanche
Trakker Antares 2400 Family System Manual
11
Page 32
Chapter 2 - Configuring and Managing the Terminals
How to Configure the Terminals You can customize many operating characteristics of the 2400 Family of terminals such as the volume of their audio signals and the bar code symbologies they decode. These characteristics are controlled by configuration parameters. The values you set for the configuration parameters determine how the terminal operates. To learn about each parameter, see Chapter 6, “Configuration Command Reference.” This chapter describes how to configure terminals using the UDP Plus or TCP/IP networks. If you are using a WTP network, see the appropriate TE 2000™ user’s guide. You can configure the terminals by using any of these methods: How to Configure the Terminals
12
Method Use the TRAKKER Antares 2400 Menu System
Description With menus and screens, the TRAKKER Antares 2400 Menu System lets you view the current configuration and modify configuration parameters. For help, see your user’s manual.
Scan bar code labels
You can change the terminal’s configuration parameters by scanning Code 39 or Code 93 bar code labels that contain configuration commands. This method is a fast, easy way to change the terminal’s configuration. You can scan the bar code labels in this manual, or you can create your own bar code labels. For help, see “Configuring the Terminal by Scanning Bar Code Labels” on page 13.
Send commands through the serial port
You can change the terminal’s configuration parameters by sending commands from a host computer or PC that is connected to the terminal’s serial port. For help, see “Configuring the Terminal Through the Serial Port” on page 15.
Send commands through the Ethernet or RF port
You can change the terminal’s configuration parameters by sending commands through the UDP Plus or TCP/IP network. This method lets you configure one or more terminals at the same time. For help, see “Configuring the Terminal Through the Network” on page 17.
Use the clone application
You can set the terminal’s configuration parameters by using the clone application to copy configuration parameters from one terminal to another. This method is a fast, easy way to configure your new terminals with the same parameters as your existing terminals. For help, see “Configuring the Terminal With the Clone Application” on page 23.
Use the Wavelink Avalanche Manager
You can send configuration information to multiple terminals in your RF network using the Wavelink Avalanche client management system and the Intermec Settings (ICCU) application. For help, see “Managing Your Terminals with Wavelink Avalanche” on page 38.
Trakker Antares 2400 Family System Manual
Page 33
Chapter 2 - Configuring and Managing the Terminals
About the Configurations The terminal uses three configurations: current, active, and default. Having separate current and active configurations lets you control the active configuration while letting each operator make some changes to the current configuration, such as scanning a bar code to change the beep volume. Trakker Antares Configurations Configuration Current
Description This configuration, also called the runtime configuration, uses the configuration that is saved in RAM. When you change a parameter by using the menu system, by scanning a bar code, by sending it from a host application, or by sending it from the DCS 300, the terminal updates the current configuration. The changes to the current configuration are lost when you boot or reset the terminal.
Active
When you update the flash memory, the terminal copies the current configuration to the active configuration. The active configuration is the configuration that the terminal uses when you boot or reset the terminal.
Default
This configuration is the factory default configuration. You may want to restore the default configuration. For help, see “Restoring the Terminal’s Default Configuration” on page 30.
Configuring the Terminal by Scanning Bar Code Labels You can configure the terminal by scanning bar code labels that are listed in this manual or by creating your own Code 39 or Code 93 bar code labels. For example, you can scan this bar code label to set the beep volume to a quiet audio level: Set Beep Volume to Quiet
*$+BV1* *$+BV1*
Note: If you are working in the TRAKKER Antares 2400 Menu System, you cannot scan configuration commands. Exit the menu system to scan configuration commands. As you scan bar code labels to configure the terminal, the terminal accepts and sets all commands. However, the terminal only uses the parameters that are valid for the current configuration. For example, if you configure COM1 to use the Configurable protocol, disable Handshake, and set a value for Poll, the terminal will set the value for Poll, but it will not use this value because Handshake is disabled.
Trakker Antares 2400 Family System Manual
13
Page 34
Chapter 2 - Configuring and Managing the Terminals
If you want to save your changes after you boot or reset the terminal, you must save them in the terminal’s flash memory. For help, see “Saving Configuration Changes in Flash Memory” on page 29. To configure the terminal, you can scan separate bar code labels, or you can create bar code labels that contain more than one configuration command. For example, you can create one bar code label to configure the terminal for: • One-Shot Scanner mode (SB0) • Scanner Redundancy set to high (SR2) • Beep Volume set to very loud (BV4) • Disable Keypad Clicker (KC0) One-Shot Scanner Mode, Set Scanner Redundancy to High, Set Beep Volume to Very Loud, Disable Keypad Clicker
*$+SB0SR2BV4KC0* *$+SB0SR2BV4KC0*
When you create a bar code label to set several configuration commands, follow these rules: • The bar code label must be printed using Code 39 or Code 93 symbology. If you need to scan a Code 39 bar code label that includes quotes or periods, you must configure the terminal to use Code 39 in Full ASCII mode. • The bar code label must include the start and stop character. Most bar code printing utilities automatically include the start and stop character. • The bar code label must start with $+ (Change Configuration command). • Each configuration command must include the command syntax and the value for the command. For example, BV is the command syntax for Beep Volume and the value 4 sets the beep volume to very loud. • If you set one configuration command to a string of ASCII characters and another configuration command follows, you must enclose the value in quotes. If you do not include the quotation marks, the terminal will interpret everything after the first command as data and will not find the second configuration command. • For example, to set the preamble to BV, use $+ADBV (no quotes are needed). To set the preamble to BV and turn off the beep volume, use $+AD"BV"BV0, or change the order and use $+BV0ADBV. To clear the preamble and postamble from a single label, use $+AD""AE. • To include quotation marks when you set a value, the entire value must be enclosed in quotation marks. Type two sets of quotation marks ("") to include one quotation mark as the value for a command. For example, to set the preamble to ABC"D, use $+AD"ABC""D".
14
Trakker Antares 2400 Family System Manual
Page 35
Chapter 2 - Configuring and Managing the Terminals
Configuring the Terminal Through the Serial Port You can write a host application that configures the terminal by sending reader and configuration commands through the serial port. For a list of reader commands, see Chapter 5, “Reader Command Reference.” For a list of configuration commands, see Chapter 6, “Configuration Command Reference.” You must connect the terminal to the host by either using a special cable or a communications dock and a special cable. Once the terminal and the host are communicating, you can configure the terminal. If you are using the Configurable protocol, you must enable Frame mode and the Configuration Commands Via Serial Port command. You cannot configure the terminal through the serial port if you are using Configurable protocol with no EOM or Binary protocol on that port. You can continue running an application on the terminal while configuring the terminal from the host. However, if you send a configuration command that changes the serial port parameters, you may not be able to continue sending commands unless you also reconfigure your host. You can also improve TMF performance by disabling the Network Activate command before sending commands through the serial port. For help, see “Network Activate” on page 210. To set up the application • Write a host application that can send transactions to and receive transactions from the terminal in this format: SOM
TMF field commands
EOM where: SOM is the start of message field.
TMF field is only used if the Configuration Commands Via Serial Port are enabled with TMF. It is a 2-byte field containing one of these values: CG
Configuration Get request sent from the host application.
Cg
Configuration Get response sent from the terminal to the host.
CS
Configuration Set request sent from the host application.
Cs
Configuration Set response sent from the terminal to the host.
To send data to an application instead of sending configuration commands, use the letter A followed by a space in the TMF field. If the TMF field does not contain CG, Cg, CS, Cs, or A, the terminal ignores the transaction.
Trakker Antares 2400 Family System Manual
15
Page 36
Chapter 2 - Configuring and Managing the Terminals commands are the reader and configuration commands that you want to set on the terminal or get the current value of from the terminal. To save configuration changes in flash memory, send the reader command .+1 as the last command.
EOM is the end of message field. If the Configuration Commands Via Serial Port command is enabled without TMF or if you are using a protocol other than Configurable, leave this field blank.
Note: For security purposes, you cannot get the values for Security ID and WEP Key. To get the value for Symbology Identifiers, you need to use the command syntax and the value for Parameter 1. For example, to get the value for the Code 39 symbology identifier, use CY01. For help, see “Symbology Identifiers” on page 245.
Example with TMF In the host application, you want to set the values for the beep volume and keypad caps lock on the terminal. Send this transaction from the host application: CS$+BV4KA1.+1
Note: SOM and EOM are not shown in this example. where: CS is a TMF Configuration Set request.
$+ is the Change Configuration reader command.
BV4 sets the Beep Volume command to a value of 4, which is a very loud beep volume.
KA1 enables the Keypad Caps Lock configuration command.
.+1 saves the configuration changes to the terminal’s flash memory.
The terminal returns this transaction to the host application: Cs$+BV4KA1.+1 where:
16
Cs is a TMF Configuration Set response.
$+ is the Change Configuration reader command.
Trakker Antares 2400 Family System Manual
Page 37
Chapter 2 - Configuring and Managing the Terminals
BV4 means the Beep Volume command has been changed to a value of 4, which is a very loud beep volume.
KA1 means the Keypad Caps Lock configuration command was enabled.
.+1 means the configuration changes have been saved in flash memory.
Configuring the Terminal Through the Network You can remotely configure the RF or Ethernet terminal by using one of these methods: • Send a command from the DCS 300 (UDP Plus network only). • Send a command from an application on the host computer (UDP Plus and TCP/IP networks). Before you can send a command to the terminal, it must be communicating with the RF network. You must have already installed and configured the access points. If you are using a UDP Plus network, you must have installed and configured the DCS 300. You can modify most RF network parameters through the network, except for these parameters: • Acknowledgement Delay Lower Limit • Acknowledgement Delay Upper Limit • Controller Connect Check Receive Timer • Controller Connect Check Send Timer • DHCP (Controller) • DHCP (Terminal) • Maximum Retries • Network Activate • TCP Maximum Retries • TCP/IP Maximum Transmit Timeout You can modify these parameters or configure the terminal locally by using the TRAKKER Antares 2400 Menu System or by scanning a command from a Code 39 or Code 93 bar code label. Note: You can continue running an application on the terminal while configuring the terminal from the network.
Trakker Antares 2400 Family System Manual
17
Page 38
Chapter 2 - Configuring and Managing the Terminals
Sending a Command From the DCS 300 You can use the DCS 300 to configure one or more terminals in your RF or Ethernet network. The DCS 300 lets you group together terminals that you want to receive the same reader and configuration commands. This method is very efficient if you need to change the same configuration parameters for several terminals in one area. For example, you may want to set the Beep Volume to very loud and turn on Keypad Caps Lock for all the terminals in one area. Note: You can configure an RF or Ethernet terminal from the DCS 300, but you cannot get configuration data from the terminal. To send commands from the DCS 300 1 Using the Download Server feature on the server, select the terminal or group to which you want to download the reader and configuration commands, and then choose Edit. For help configuring a group of terminals, see the DCS 300 User’s Manual (P/N 067296). 2 In the Initialization Data box, choose the Command option button.
3 In the Initialization Data box field, enter the reader or configuration command, and then choose Add. The command appears in the Files and Data box. For example, enter this command to set the Beep Volume to very loud: $+BV4
18
Trakker Antares 2400 Family System Manual
Page 39
Chapter 2 - Configuring and Managing the Terminals
Note: You can set the Postamble or Preamble configuration command to use characters from the extended ASCII character set such as the Field Exit code for 5250 TE. For help, see the appropriate TE manual. 4 Repeat Step 3 to add another reader or configuration command, or choose OK. 5 To save the configuration changes in flash memory, enter .+1 as the last command. If you do not save the configuration changes in flash memory, the commands only change the current configuration. 6 Choose OK. The Terminal Download Configuration dialog box appears. 7 Choose Download to download the commands and change the configuration of the selected terminals.
Sending a Command From the Host You can write a host application that configures one RF or Ethernet terminal. This host application must be able to communicate with the DCS 300 in a UDP Plus network or directly through the access point in a TCP/IP direct connect network.
Configuring the Terminal in a UDP Plus Network You can use the host computer to configure a terminal in your RF or Ethernet network. To send and receive configuration data or files, you need to write a host application that can communicate with the DCS 300. For help, see the DCS 300 User’s Manual. You use the Terminal Message Format (TMF) protocol to send and receive transactions between the host application and the terminal. To set up the DCS 300 • Configure a peer-to-peer destination name for the host application. Create a transaction ID, $NGCFGRSP, that will be routed to this destination name. The DCS 300 uses the transaction ID to route responses from the terminal back to the host application. $NGCFGRSP is a special transaction ID that the server uses to forward configuration response data from a terminal. All configuration responses will be routed with the $NGCFGRSP transaction ID. The DCS 300 cannot keep track of multiple applications sending reader or configuration commands. If you have two host applications sending reader or configuration commands, they must both be configured to receive the $NGCFGRSP transactions, and therefore both will receive all responses from all terminals.
Trakker Antares 2400 Family System Manual
19