Page 321

D

Using Default and Optional Applications

This appendix describes how to determine which default applications you may have loaded on your terminal. It also describes how to use the APPTSK.BIN and EM9560.BIN applications and describes how to use the optional DOS applications. This appendix covers these topics: • About the applications shipped on the terminal • Defining APPTSK.BIN and EM9560.BIN • Using DOS on the terminal

Trakker Antares 2400 Family System Manual

301

Page 322

Appendix D - Using Default and Optional Applications nugget

39 AGaramond

About the Applications Shipped on the Terminal Unless you have the 802.1x security option, the Trakker Antares® terminals ship with these two applications: • APPTSK.BIN • EM9560.BIN Both applications are stored on drive C. In addition to these two applications, your terminal may have a TE 2000™ terminal emulation application or a Data Collection Browser™ (dcBrowser™) application stored on drive C. To determine which application you may have loaded on your terminal, continue with the next section, “Identifying the Default Applications.” If you ordered the DOS option, the terminal ships with the necessary DOS files you need to run DOS applications. For help using DOS applications, see “Using DOS on the Terminal” on page 313. To learn how to use the APPTSK.BIN and EM9560.BIN applications, see “Defining APPTSK.BIN and EM9560.BIN” on page 303.

Identifying the Default Applications Your terminal may have a TE 2000 terminal emulation application or a dcBrowser application stored on drive C. This section helps you identify which of these applications you may have installed on your terminal.

TE 2000 Terminal Emulation 1 On your terminal, press ( ¡ to access the TE 2000 menu. If you have a 241X with a 37-key keypad, press ( 5. If you have a 243X, press r l. 2 If you have TE 2000 terminal emulation, the TE 2000 main menu appears. Main Menu 1) 2) 3) 4) 5) 6) 7)

Set-up Parms LCD Parms Tests Version Info Exit Menus More

24XXS080.eps

3 By default, your terminal is configured for TE 2000 VT/ANSI. To change the configuration to TE 2000 5250 or TE 2000 3270, from the TE 2000 main menu, select Set-up Parms and press ;. A password prompt appears.

302

Trakker Antares 2400 Family System Manual

Page 323

nugget

39 AGaramond Appendix D - Using Default and Optional Applications 4 Type C R 5 2 4 0 1 and press ;. 5 Select Protocol Opts > Data Stream, and then select the appropriate TE 2000 configuration. 6 Save your changes by selecting Exit Menus from the TE 2000 main menu. Press Y, and type C R 5 2 4 0 1 at the Enter Password prompt. For information about using TE 2000 IBM 3270, TE 2000 IBM 5250, or TE 2000 VT/100/220/320 and ANSI terminal emulation, see the appropriate TE 2000 guide: • TE 2000 5250 Terminal Emulation Programmer’s Guide (P/N 977-055-004) • TE 2000 3270 Terminal Emulation Programmer’s Guide (P/N 977-055-003) • TE 2000 VT/ANSI Terminal Emulation Programmer’s Guide (P/N 977-055-005)

dcBrowser Client 1 On your terminal, access the TRAKKER Antares 2400 Menu System by pressing ) ; 2 4 8 or by scanning this bar code: TRAKKER Antares 2400 Menu System

*..-.*

*..-.*

2 From the Main Menu, choose System Menu > File Manager. 3 Select drive C and then press Enter. A list of applications that are loaded on your terminal appears. If you have the dcBrowser client loaded on your terminal, this filename is listed: DCBT24.BIN

If you do not see this filename, you do not have the dcBrowser client loaded on your terminal. For information about using dcBrowser, see the online help that ships with your dcBrowser gateway software.

Defining APPTSK.BIN and EM9560.BIN Unless you have the 802.1x security option, you can run APPTSK.BIN or EM9560.BIN.

APPTSK.BIN This application is the default application on all terminals. If you exit an application or if certain errors occur, the terminal resets and runs

Trakker Antares 2400 Family System Manual

303

Page 324

Appendix D - Using Default and Optional Applications nugget

39 AGaramond

APPTSK.BIN. You can use APPTSK.BIN to scan, enter, transmit, and display data.

EM9560.BIN This application emulates a subset of the functionality available on the Intermec 95XX terminals, such as the 9512 and 9560. You can use EM9560.BIN to scan, enter, transmit, and display data. APPTSK.BIN and EM9560.BIN include these features: • Works with any protocol that is supported on the terminal. Both the terminal and the device you are communicating with must use the same protocol (serial, Ethernet, or RF) and parameter settings. • Sends scanned or keyboard data out all serial, Ethernet, or RF ports. • Buffers the keyboard data until you press ;. • Receives data from any serial, Ethernet, or RF port, displays the data on the terminal screen, and parses the data for commands. • Receives data through any serial port and transmits it out the Ethernet or RF port. • Receives data through the Ethernet or RF port and transmits it out all serial ports. • (APPTSK.BIN only) Displays the time and date, which can be toggled on and off. The main difference between the two applications is that you can use the EM9560.BIN application to emulate specific functions of the 95XXs.

Defining the Emulation Features of EM9560.BIN With the EM9560.BIN application, you can use the programmable terminal as a remote input/output terminal in which all prompts and commands are controlled by the host computer. With this application, the terminal is similar to a 95XX in Data Entry mode with no application running. Note: For the 95XXs, Data Entry mode with no application running is also referred to as an unprogrammed state or 95XX dumb terminal mode. EM9560.BIN lets you use the terminal to emulate these specific 95XX features: • An Enter key without any preceding data transmits an empty data packet. • The terminal display is similar to, but not identical to, the 9560 buffered display mode. • All function keys transmit the corresponding characters F1, F2, and so on. 304

Trakker Antares 2400 Family System Manual

Page 325

nugget

39 AGaramond Appendix D - Using Default and Optional Applications • When Code 128 is configured for Standard Code 128 symbology and you scan a UCC/EAN label, the terminal will discard the Function 1 characters. Although this does not meet the industry standard for Code 128, it does emulate the 95XX, which was manufactured before the current standard was established. Other Code 128 configurations work as defined in this system manual. • The Set Time and Date reader (data entry) command is supported. When the terminal receives a time broadcast command (/+) from the 9154 or 9161 controller, the command sets the clock on the terminal. • The High Beep reader command is supported. When a backslash character (\) is sent to the terminal through any serial or network port, the terminal sounds a high beep. • The Low Beep reader command is supported. When the BEL character is sent to the terminal through any serial or network port, the terminal sounds a low beep. • When control codes (ANSI escape sequences) are sent to the terminal through any serial or network port, the terminal formats the display. For a list of control codes, see the next section, “Using Display Control Codes.” • Buffered and transparent display modes are supported. The Display Setting configuration command (OD) is also supported. For help, see “Using Display Modes” on page 306. • You can emulate Accumulate mode so that keypad data can be combined with scanned data. For help, see “Using Accumulate Mode” on page 307. • Preamble A, Preamble B, and Postamble C are supported through the AA, AB, and AC configuration commands or through the reader commands +., ++, and +%. For help, see “Setting Preambles and Postambles” on page 308. • Full ASCII mode for Code 39 can be configured through the CB or RB configuration commands or through the reader commands +$ and -$. For help, see “Full ASCII Mode for Code 39” on page 309. • You can add message headers that indicate the length of the message. For help, see “Using Message Length Headers” on page 310. • The Exit Configuration Mode, Save Settings configuration command ($-) is not required, but bar code labels with this command scan correctly.

Using Display Control Codes You can use control codes to position the cursor or to format the terminal display. The EM9560.BIN application recognizes the display control codes listed next.

Trakker Antares 2400 Family System Manual

305

Page 326

Appendix D - Using Default and Optional Applications nugget

39 AGaramond

Display Control Codes Command Backspace

Control Code BS (08 Hex)

Cursor Position

ESC[n;vH

Description or Action Moves the cursor one position to the left until the cursor reaches the first column. If the cursor is in the first column of any row except the first row, a Backspace command moves the cursor to the last column of the previous row. Moves the cursor to the position specified by the n and v parameters where: n specifies the row or line number. v specifies the column number. If you enter zero or no parameter, n and v are set to one. If n or v exceeds the maximum row or column number on the display, the parameters are set to the screen’s maximum.

Erase Display

ESC[2J

Erases the entire display and returns the cursor to the home position (row 1, column 1). This command also erases the entire virtual display image (buffer with up to four rows of the most recently displayed data).

Home

CR (0D Hex)

Returns the cursor to the first column of the current row.

Next Line

LF (0A Hex)

Moves the cursor down one row in the current column position. If the cursor is already in the last row, a new line is added.

Restore Cursor Position

ESC[u

Restores the cursor position saved with a Save Cursor Position command. Each Restore Cursor Position command must be paired with a preceding Save Cursor Position command. If a Save Cursor Position command has not been previously entered, the cursor position will not change.

Save Cursor Position

ESC[s

Saves the current cursor position. Successive Save Cursor Position commands overwrite the previous position that was saved.

Using Display Modes With the EM9560.BIN application, you can use Buffered display mode and Transparent display mode. In Buffered mode, new data is placed on a new line keeping blocks of data separated. In Transparent mode, new data is placed at the current cursor position, which makes screen formatting by the host easier.

306

Trakker Antares 2400 Family System Manual

Page 327

nugget

39 AGaramond Appendix D - Using Default and Optional Applications

Syntax: DMdata Acceptable values for data are: 0 1 Default:

Buffered display mode Transparent display mode

Transparent display mode

Bar Codes: Scan one of these bar codes: Buffered Display Mode

*$+DM0* *$+DM0*

Other:

Transparent Display Mode

*$+DM1*

*$+DM1*

To provide compatibility with the 95XX, you can also use this syntax: ODdata where data is a 0 or 1.

Using Accumulate Mode With the EM9560.BIN application, you can emulate Accumulate mode (Emulation mode). Data that you accumulate appears on the bottom line of the terminal display. You can edit this data using the reader commands for backspace and clear or you can use the « key. You scan a bar code to toggle between Emulation mode and Native mode. Default:

Native mode Note: To set this command using bar code labels, you must also use the bar code labels in Appendix B. To use these labels, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Full ASCII Mode for Code 39” on page 309 or “Code 39” on page 146.

Bar Codes: To use Emulation mode: 1 Scan this bar code: Toggle Emulation Mode/Native Mode

*ACCUMULATE*

*ACCUMULATE*

2 Scan this bar code: Enter Accumulate Mode

*+/*

*+/*

3 Scan data from the “Full ASCII Bar Code Chart” on page 284, or type data using the keypad.

Trakker Antares 2400 Family System Manual

307

Page 328

Appendix D - Using Default and Optional Applications nugget

39 AGaramond

4 Scan this bar code: Exit Accumulate Mode

*/M/O*

*-/*

Setting Preambles and Postambles With the EM9560.BIN application, you can set Preamble A, Preamble B, and Postamble C on the terminal and make it compatible with the 95XXs. The preambles are prepended and the postamble is appended to the data that is transmitted through all the serial ports. Preamble A, Preamble B, and Postamble C can each be up to 25 ASCII characters in length. If you enter a preamble or postamble command without entering data, the preamble or postamble buffer is cleared. Syntax: Preamble A Preamble B Postamble C

AAdata or +.data ABdata or ++data ACdata or +%data

Note: To set this command using bar code labels, you must also use the bar code labels in Appendix B. To use these labels, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Full ASCII Mode for Code 39” on page 309. Bar Codes: To set the preamble or postamble using the AA, AB, or AC configuration commands: 1 Scan one of these bar code labels: Enter Accumulate Mode / Set Preamble A

Enter Accumulate Mode / Set Preamble B

*+/$+AA*

*+/$+AB*

*+/$+AA*

*+/$+AB*

Enter Accumulate Mode / Set Postamble C

*+/$+AC*

*+/$+AC*

2 Scan a value for data from the “Full ASCII Bar Code Chart” on page 284. The preamble or postamble can be from 1 to 25 characters. 3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

4 Repeat Steps 1 to 3 to set another preamble or postamble.

308

Trakker Antares 2400 Family System Manual

Page 329

nugget

39 AGaramond Appendix D - Using Default and Optional Applications

Or: To set the preamble or postamble using the +., ++, or +% reader commands: 1 Scan one of these bar code labels: Enter Accumulate Mode / Set Preamble A

*+/+.*

*+/+.*

Enter Accumulate Mode / Set Preamble B

*+/++*

*+/++*

Enter Accumulate Mode / Set Postamble C

*+/+%*

*+/+%*

2 Scan a value for data from the “Full ASCII Bar Code Chart” on page 284. The preamble or postamble can be from 1 to 25 characters. 3 Scan this bar code: Exit Accumulate Mode

*-/*

*-/*

4 Repeat Steps 1 to 3 to set another preamble or postamble.

Full ASCII Mode for Code 39 With the EM9560.BIN application, you can configure Full ASCII mode for Code 39 using any of these commands: • Code 39 configuration command (CB) • Enter Full ASCII Mode reader command (+$) and the Exit Full ASCII Mode reader command (-$) The last two commands are compatible with the 95XXs. Each command is described next. For help with the Code 39 configuration command (CB), see “Code 39” on page 146. Note: Use the CB configuration command unless your terminals need to be compatible with the 95XXs in your data collection network. Command: Enter Full ASCII Mode reader command Description: Enables Code 39 Full ASCII mode so the terminal decodes Code 39 bar code labels by using a two-character encoding scheme to extend the character set to 128 characters. For a list of ASCII characters, see the “Full ASCII Table” on page 282. Syntax: +$

Trakker Antares 2400 Family System Manual

309

Page 330

Appendix D - Using Default and Optional Applications nugget

39 AGaramond

Bar Codes: Full ASCII

*+$* *+$*

Command: Exit Full ASCII Mode reader command Description: Exits Code 39 Full ASCII mode and puts the terminal in Code 39 NonFull ASCII mode (one-character encoding scheme). Syntax: -$ Bar Codes: Exit Full ASCII

*/M/D* *-$*

Using Message Length Headers You can use the EM9560.BIN application to add message headers that indicate the length of the message. When you send or receive a message, the application pre-appends a header to the message. If the message being received already has a header, the application strips the existing header and pre-appends the new message length header. You can create a two-byte binary header, a four-byte ASCII header, or a mixed mode header. A mixed mode header pre-appends a four-byte ASCII header to received messages and a two-byte binary header to sent messages. Syntax:

NHdata Acceptable values for data are: 0 1 2 3

Default: Bar Codes:

No header Two-byte binary header on messages sent and received Four-byte ASCII header on messages sent and received Four-byte ASCII header on messages sent and two-byte binary header on messages received

No header Scan one of these bar codes: No Header

*$+NH0*

*$+NH1*

*$+NH0*

*$+NH1*

Four-Byte ASCII Header Byte Binary Header

Four-Byte ASCII / Two-

*$+NH2* *$+NH2*

310

Two-Byte Binary Header

*$+NH3*

*$+NH3*

Trakker Antares 2400 Family System Manual