The text of a manual · part 32 of 38
Trakker Antares 2400 Family System Manual: Appendix A - Default Configurations and Command Syntax
Pages 291 to 300 of 362, from Trakker Antares 2400 Family System Manual
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 2410, Intermec 2415, Intermec 2435 and Intermec 2475
Page 291
A
Default Configurations and Command Syntax
This appendix lists the default configuration values and provides a configuration command reference list in alphabetical order by command syntax.
Trakker Antares 2400 Family System Manual
271
Page 292
Appendix A - Default Configurations and Command Syntax
Default Configuration The next tables list the terminal’s default configuration values. You can use the TRAKKER Antares 2400 Menu System to set the terminal to the default configuration. For help, see “Restoring the Terminal’s Default Configuration” on page 30. Not all configuration commands apply to all terminals. To determine which commands apply to your Trakker Antares® terminal, see “Configuration Commands Listed by Category” starting on page 125. Bar Code Symbology Default Configuration Bar Code Symbology Codabar
Default Value Disabled
Code 11
Disabled
Code 2 of 5
Disabled
Code 39
Full ASCII Code 39 enabled with no check digit
Code 93
Disabled
Code 128
Standard
Interleaved 2 of 5
Disabled
MSI
Disabled
PDF417
Disabled
Plessey
Disabled
UPC/EAN
UPC-A/EAN-13 enabled, UPC-E and EAN-8 enabled, supplementals allowed, transmit check digit, transmit number system digit, and retain leading zero for UPC-A
GTIN Compliance
Disabled
Operations Default Configuration
272
Operations Command Append Time
Default Value Disabled
Automatic Shutoff
0 minutes (disabled)
Beep Duration
150 ms high, 50 ms low (243X) 50 ms high, 50 ms low (241X, 242X, 2455, 246X, 2475, 248X)
Beep Frequency
2400 Hz high, 1400 Hz low (241X) 1900 Hz high, 1050 Hz low (243X) 2400 Hz high, 1200 Hz low (242X, 2455, 2475, 248X)
Beep Volume
Very loud
Character Set
U.S. ASCII
Command Processing
All reader commands enabled
Trakker Antares 2400 Family System Manual
Page 293
Appendix A - Default Configurations and Command Syntax
Operations Default Configuration (continued) Operations Command Decode Security
Default Value Moderate
Display Backlight Timeout
10 seconds
Display Spacing
00000 (8x8 font size, no column spacing, no row spacing)
Display Contrast
3 (maximum contrast)
Display Cursor Style Display Font Type
8x16 font
Display Row Spacing
0
Display Video Mode
Original
Flash Memory Configuration
0 (flash memory for double-byte fonts)
Keypad Caps Lock
Caps lock off
Keypad Clicker
Enabled
Keypad Control
Enabled
Keypad Type
Hardware default
Postamble
No characters (disabled)
Preamble
No characters (disabled)
RAM Drive Size
0 (no RAM drive)
Resume Execution
Allowed
Scan Ahead
Disabled
Scanner Mode
One-Shot mode
Scanner Redundancy
Normal
Scanner Selection
Specific integrated scanner installed on the terminal (integrated scanners). All compatible scanners (tethered scanners)
Scanner Timeout
Disabled (no timeout)
Scanner Trigger
Level triggering
Suspend/Resume Control
Enabled
Symbology Identifiers
000 (All symbology identifiers disabled)
Time and Date
The date of the most recent firmware installation or upgrade. (See note below.)
Time in Seconds
Disabled Note: When you restore the default configuration, Time and Date is not reset to the default value. Time and Date only returns to its default value when you boot the system, upgrade the firmware, or perform a destructive reset.
Time Zone
Trakker Antares 2400 Family System Manual
8 Pacific Standard Time (PST)
273
Page 294
Appendix A - Default Configurations and Command Syntax
Serial Network Default Configuration Serial Network Command Baud Rate
Default Value 19200
Configuration Commands Via Serial Port
Enabled without TMF
Data Bits
7
End of Message (EOM)
\x03 (hexadecimal value for ETX)
Flow Control
0 (no flow control)
Handshake
Disabled
LRC (Longitudinal Redundancy Check)
Disabled
Modem Dial Sequence
0 (no dial sequence)
Modem Initialization Sequence
0 (auto rate)
Multi-Drop Address
A
Parity
Even
Poll (Polling)
Disabled
RS-232 or RS-422/485 COM2 Interface
RS-232
Scanner Port (2455 COM4 only)
Scanner enabled
Serial Port Protocol
Configurable
Start of Message (SOM)
\x02 (hexadecimal value for STX)
Stop Bits
1
Timeout Delay
10 seconds
RF or Ethernet Network Default Configuration
274
RF or Ethernet Network Command Acknowledgement Delay Lower Limit
Default Value 300 ms
Acknowledgement Delay Upper Limit
5000 ms
AP MAC Address
None
Controller Connect Check Receive Timer
60 seconds
Controller Connect Check Send Timer
35 seconds
Controller IP Address
0.0.0.0
Default Router
0.0.0.0
DHCP (Controller)
Disabled
DHCP (Terminal)
Enabled
Host IP Address
0.0.0.0
Internet Control Message Protocol (ICMP)
Disabled
Maximum Retries
7
Trakker Antares 2400 Family System Manual
Page 295
Appendix A - Default Configurations and Command Syntax
RF or Ethernet Network Default Configuration (continued) RF or Ethernet Network Command Network Activate
Default Value Disabled
Network Loopback
Disabled
Network Port
23 (Telnet) for a TCP/IP network 5555 for a UDP Plus network
Radio MAC Address
None
Subnet Mask
255.255.255.0
TCP Maximum Retries
12
TCP/IP Maximum Transmit Timeout
20 seconds
Terminal IP Address
0.0.0.0
Terminal Port
0 (random terminal port used for TCP/IP connection)
OpenAir RF Network Default Configuration OpenAir RF Network Command Domain
Default Value 0
Inactivity Timeout
5 seconds
Roaming Flag
Allowed
Security Identification (ID)
None
Transmit Mode
BFSK
Wakeup On Broadcast
No (disabled)
802.11b RF Network Default Configuration 802.11b RF Network Command AP Density
Default Value Low
Maximum Sleep Duration
100 ms
Medium Reservation
Enabled
Microwave Robustness
Disabled
Network Name
INTERMEC
Power Management
Enhanced
Receive All Multicast
Enabled
Reservation Threshold
500
Station Name
TRAKKER 2400
Transmit Rate
Maximum available
Transmit Rate Fallback
Enabled
WEP Encryption
Disabled
WEP Key
80211 (for WEP 64 on WEP Key 1)
WEP Transmit Key
1
Trakker Antares 2400 Family System Manual
275
Page 296
Appendix A - Default Configurations and Command Syntax
802.11b with 802.1x Security RF Network Default Configuration 802.11b with 802.1x Security Network Command Password
Default Value anonymous
Server 1 Certificate Common Name
None
Server 2 Certificate Common Name
None
User Name anonymous
Device Management Configuration Commands Device Management Device Management
Default Value enabled
Device Manager IP Address
0.0.0.0 (no Avalanche Agent IP address)
Configuration Commands by Syntax The next table lists all of the configuration commands that are available on the Trakker Antares terminals. The configuration commands are listed in alphabetic order by syntax. For a list of configuration commands by category, see “Configuration Commands Listed by Category” starting on page 125. Configuration Commands Listed by Syntax
276
Syntax None
Command DHCP (Terminal)
On Page 174
ADdata
Preamble
221
AEdata
Postamble
219
BDdatabeep
Beep Duration
138
BFdata
Beep Frequency
139
BVdata
Beep Volume
140
CAdata
Interleaved 2 of 5 Code (I 2 of 5)
195
CBdata
Code 39
146
CCdata
Code 2 of 5 (2 of 5)
145
CDdata
Codabar
143
CEdata
UPC/EAN
261
CFdata
Code 93
149
CGdata
Code 11
144
CHdata
Code 128
150
CIdata
Plessey
217
CNdata
MSI
208
COdata
GTIN Compliance
189
Trakker Antares 2400 Family System Manual
Page 297
Appendix A - Default Configurations and Command Syntax
Configuration Commands Listed by Syntax (continued) Syntax CQdata
Command PDF417
On Page 216
CSdata
Decode Security
168
CYdata
Symbology Identifiers
245
DAdata
Time in Seconds
256
DBdata
Time and Date
255
DCdata
Command Processing
158
DEdata
Append Time
134
DFdata
Display Backlight Timeout
175
DJdata
Display Contrast
176
DKdata
Display Spacing
180
DLdata
Display Row Spacing
179
DNdata
Display Video Mode
182
DTdata
Display Font Type
178
DXdata
Character Set
141
DZdata
Time Zone
256
EFdata
Suspend/Resume Control
245
ERdata
Resume Execution
226
EZdata
Automatic Shutoff
135
FFdata
Flash Memory Configuration
186
FRdata
RAM Drive Size
223
IXdata
Scanner Port (COM4)
229
KAdata
Keypad Caps Lock
196
KCdata
Keypad Clicker
197
KEdata
Keypad Control
197
KTdata
Keypad Type
198
LAdata
Network Name
211
LBdata
Station Name
242
LCdata
Medium Reservation
204
LDdata
Reservation Threshold
225
LEdata
Transmit Rate
260
LFdata
Transmit Rate Fallback
261
LGdata
AP Density
133
LHdata
Power Management
220
LIdata
Maximum Sleep Duration
203
LJdata
Receive All Multicast
224
LKdata
WEP Encryption
266
LLdata
WEP Transmit Key
269
LMdata
WEP Key 1
267
LNdata
WEP Key 2
267
Trakker Antares 2400 Family System Manual
277
Page 298
Appendix A - Default Configurations and Command Syntax
Configuration Commands Listed by Syntax (continued)
278
Syntax LOdata
Command WEP Key 3
On Page 267
LPdata
WEP Key 4
267
LQdata
Microwave Robustness
205
LSdata
User Name
265
LTdata
Password
215
LUdata
Server 1 Certificate Common Name
239
LVdata
Server 2 Certificate Common Name
239
NAdata
Network Activate
210
NCdata
Controller IP Address (UDP Plus network)
166
Host IP Address (TCP/IP network)
192
NDdata
Terminal IP Address
252
NGdata
Network Port
213
NHdata
TCP/IP Maximum Transmit Timeout
251
NIdata
DHCP (Controller)
173
NJdata
TCP Maximum Retries
250
NLdata
Network Loopback
211
NPdata
Controller Connect Check Receive Timer
163
NQdata
Controller Connect Check Send Timer
164
NRdata
Maximum Retries
202
NSdata
Subnet Mask
243
NTdata
Terminal Port
254
NUdata
Acknowledgement Delay Upper Limit
132
NVdata
Acknowledgement Delay Lower Limit
131
NXdata
Default Router
169
NZdata
ICMP (Internet Control Message Protocol)
193
RA
AP MAC Address
134
RBdata
Wakeup On Broadcast
266
RI
Radio MAC Address
222
RRdata
Roaming Flag
227
RSdata
Security Identification
236
RTdata
Transmit Mode
259
RWdata
Domain
183
RYdata
Inactivity Timeout
193
SAdata
Scanner Timeout
233
SBdata
Scanner Mode
228
SCdata
Scanner Trigger
235
SDdata
Scan Ahead
228
SRdata
Scanner Redundancy
230
SSdata
Scanner Selection
231
Trakker Antares 2400 Family System Manual
Page 299
Appendix A - Default Configurations and Command Syntax
Configuration Commands Listed by Syntax (continued) Syntax UDdata
Command Device Management
On Page 170
UEdata
Device Manager IP Address
171
YAn.data
Baud Rate
136
YBn.data
Parity
214
YCn.data
Stop Bits
242
YD3.data
Modem Dial Sequence
205
YEn.data
Timeout Delay
257
YFn.data
LRC (Longitudinal Redundancy Check)
201
YIn.data
Data Bits
167
YJn.data
Handshake (also known as AFF)
190
YK2.data
RS-232 or RS-422/485 COM2 Interface
226
YLn.data
Flow Control
187
YM3.data
Modem Initialization Sequence
206
YN2.data
Multi-Drop Address
209
YRn.data
Poll (Polling)
218
YTn.data
Configuration Commands Via Serial Port
161
YUn.data
Serial Port Protocol
237
YYn.data
Start of Message (SOM)
240
YZn.data
End of Message (EOM)
184
Trakker Antares 2400 Family System Manual
279
Page 300
Appendix A - Default Configurations and Command Syntax
280
Trakker Antares 2400 Family System Manual