Page 125

Chapter 5 - Reader Command Reference

If you disable multiple-read labels, the terminal processes the bar code label as a regular label and reads and decodes the space as data. A regular bar code label is executed as soon as you scan it. From Network: Not supported Keypad or Menu:

Not supported

Label Syntax: <Start Code><SP>data<Stop Code> where <SP> is the ASCII space character and data is the content of the label. Example:

Multiple-Read Bar Code Label

* A* * A*

After you scan a multiple-read bar code label, the accumulated data appears on the bottom line of the terminal screen. You can use the Accumulate mode commands, such as Backspace or Clear, to edit the data.

Receive File There are three ways to receive files on the Trakker Antares terminals: • Use the serial port to receive files on the terminal • Use the serial port to receive and convert 7-bit ASCII files to 8-bit binary files on the terminal • Use network communications to receive files on the RF or Ethernet terminal For help connecting the terminal to a host computer or the DCS 300, see your user’s manual.

Receive File Through the Serial Port Description: Receives a file from the host computer through the serial port and saves it on the terminal. On the host, you must transmit the file using a serial communications package (i.e., Windows 3.1 Terminal, Win95 HyperTerminal, Crosstalk, or ProComm) that supports one of these protocols: • XMODEM • XMODEM-1K • YMODEM XMODEM-1K is a version of XMODEM that supports 1024-byte blocks and the standard 128-byte XMODEM data blocks, which increases the throughput. YMODEM has the additional ability to transfer a file name with the file’s data, and it preserves the length of the file without padding. With YMODEM, you can also receive a batch of files on the terminal. Trakker Antares 2400 Family System Manual

105

Page 126

Chapter 5 - Reader Command Reference

Note: Trakker Antares filenames are up to eight characters with a threecharacter extension. Files you transfer from the host must use the Trakker Antares naming conventions. From Network: .%Xn,drive:filename

Receives a file using XMODEM protocol

.%Kn,drive:filename

Receives a file using XMODEM-1K protocol

.%Yn,drive:filename

Receives a file using YMODEM protocol

Or: .%Yn,drive:

Receives a batch of files using YMODEM where: .%X is the command to receive a file using XMODEM protocol.

.%K is the command to receive a file using XMODEM-1K protocol.

.%Y is the command to receive a file using YMODEM protocol.

n indicates the terminal’s serial port: 1, 2, or 4.

drive:

indicates the drive on the terminal where you want to receive and store the file. You must include the colon (:) after the drive letter.

filename is the file you want to receive and save on the terminal. Keypad or Menu:

Not supported Note: To scan these bar code labels, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146.

Scan:

Follow these steps: 1 Scan this bar code label: Enter Accumulate Mode / Receive File

*/K/O./E*

*+/.%*

2 Scan the bar code label for the communications protocol you want to use. XMODEM

*X*

*X*

XMODEM-1K

YMODEM

*K*

*Y*

*K*

*Y*

3 Scan the bar code label for the terminal COM port you are using to receive the file. The label also includes the required comma. COM1

*1/L*

*1,*

106

COM2

*2/L*

*2,*

COM4

*4/L*

*4,*

Trakker Antares 2400 Family System Manual

Page 127

Chapter 5 - Reader Command Reference

4 Scan the bar code label or labels for the file you want to receive. You can scan labels from the “Full ASCII Bar Code Chart” on page 284. The label must use this format: drive:filename

5 Scan this bar code label to exit Accumulate mode and receive the file. Exit Accumulate Mode

*-/*

*-/*

Or: You can create your own bar code labels to receive files by creating a bar code in this command format:

Example:

.%Xn,drive:filename

(for XMODEM)

.%Kn,drive:filename

(for XMODEM-1K)

.%Yn,drive:filename

(for YMODEM)

To receive the file SHIPPING.BIN on the terminal’s drive C by using the XMODEM protocol through COM1, use this command: .%X1,c:shipping.bin

Batch Transfer: To transfer a batch of files to the terminal by using the YMODEM protocol, use your serial communications package to start the transfer. You usually select a batch of files using a wild card file specification. The host must send only the filename and extension, not the drive and directory path in the data stream. Next, use this command to receive the files on the terminal: .%Yn,drive:

For example, to receive the files through COM1 to drive C on the terminal, use this command: .%Y1,c:

All files that match the wild card specification are transferred from the host and received to drive C on the terminal. If any file does not transfer, the remainder of the batch transfer is aborted.

Receive and Convert 7-Bit ASCII Files to 8-Bit Binary Files Description: Receives a file from the host computer through the serial port, converts the file from a 7-bit ASCII hexadecimal file to an 8-bit binary file, and saves the file on the terminal. You must have the terminal connected to the host through a serial port. For help, see your user’s manual. Terminal applications are 8-bit binary files. Some network protocols like the Intermec Multi-Drop protocol in a CrossBar network use 7-bit ASCII files. When you send 8-bit binary files across a 7-bit system without converting the files, the files are not compatible and will not run on the terminal.

Trakker Antares 2400 Family System Manual

107

Page 128

Chapter 5 - Reader Command Reference

On the host, you use a hexadecimal conversion utility to convert the 8-bit binary file to a 7-bit ASCII hexadecimal file. Intermec has a DOS utility called HEX.EXE to convert files. The source code for HEX.EXE is also available. For help, see your Intermec service representative. Once the file is converted to a 7-bit ASCII hexadecimal file, you use the Receive File command and a host utility to transfer the 7-bit file to the terminal and convert it back to an 8-bit file. Note: Trakker Antares filenames are up to eight characters with a threecharacter extension. Files you transfer from the host must use the Trakker Antares naming conventions. From Network: .%Hn,drive:filename where:

Keypad or Menu:

.%H is the command to receive a file that was converted from 7-bit ASCII hexadecimal and convert it back to an 8-bit binary file. The terminal uses the current serial port configuration (protocol, baud rate, etc.) for the file transfer.

n indicates the terminal’s serial port: 1, 2, or 4.

drive:

indicates the drive on the terminal where you want to receive and store the file. You must include the colon (:) after the drive letter.

filename is the file you want to receive and save on the terminal.

Not supported Note: To scan these bar code labels, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146.

Scan:

Follow these steps: 1 Scan this bar code label: Enter Accumulate Mode / Receive File

*/K/O./EH*

*+/.%H*

2 Scan the bar code label for the terminal COM port you are using to receive the file. The label also includes the required comma. COM1

COM2

COM4

*1/L*

*2/L*

*4/L*

*1,*

*2,*

*4,*

3 Scan the bar code label or labels for the file you want to receive. You can scan labels from the “Full ASCII Bar Code Chart” on page 284. The label must use this format: drive:filename

108

Trakker Antares 2400 Family System Manual

Page 129

Chapter 5 - Reader Command Reference

4 Scan this bar code label to exit Accumulate mode and receive the file. Exit Accumulate Mode

*-/*

*-/*

Or: You can create your own bar code labels to receive files by creating a bar code in this command format: .%Hn,drive:filename

Example:

You want to send an application from the host in your CrossBar network to the terminal. On the host, use HEX.EXE to convert the application from SHIPPING.BIN to SHIPPING.HEX. On the host, use a utility such as InterScan to transmit SHIPPING.HEX through the 9154 or 9161 to the terminal. Enter this command to receive the file SHIPPING.BIN on the terminal’s drive C through COM2: .%H2,c:shipping.bin

The file SHIPPING.HEX is transferred, converted from 7-bit ASCII hexadecimal to 8-bit binary, and stored as SHIPPING.BIN on the terminal.

Receive File Through Network Communications Description: Receives a file from the DCS 300 or host and saves it on the RF or Ethernet terminal. From Network: .%R,fromfilename,drive:tofilename where: .%R is the command to receive a file that is transmitted over the RF or Ethernet network to the terminal.

fromfilename is the name of the file you are transmitting from the DCS 300 or host to the terminal. On the DCS 300, the file must be sent from the D:\USERDATA directory. To receive a file from the host, you must identify the path and filename.

Note: Do not enter D:\USERDATA in the fromfilename field.

Keypad or Menu:

drive:

indicates the drive on the RF or Ethernet terminal where you want to receive and store the file. You must include the colon (:) after the drive letter.

tofilename is the name of the file you want to save on the RF or Ethernet terminal.

Not supported

Trakker Antares 2400 Family System Manual

109

Page 130

Chapter 5 - Reader Command Reference

Note: To scan these bar code labels, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146. Scan:

Follow these steps: 1 Scan this bar code label: Enter Accumulate Mode / Receive File

*/K/O./ER/L*

*+/.%R,*

2 Scan the bar code labels for the file you want to receive. You can scan labels from the “Full ASCII Bar Code Chart” on page 284. The label must use this format: fromfilename,drive:tofilename

3 Scan this bar code label to exit Accumulate mode and receive the file. Exit Accumulate Mode

*-/*

*-/*

Or: You can create your own bar code labels to receive files by creating a bar code in this command format: .%R,fromfilename,drive:tofilename

Example:

To receive the file SHIPPING.BIN on the terminal’s drive C, use this command: .%R,shipping.bin,c:shipping.bin

Rename File Description:Renames a file stored on the terminal. From Network: ...-drive:oldfilename,drive:newfilename where:

110

...- is the command to rename a file.

drive:

indicates the drive where the oldfilename is stored. You must include the colon (:) after the drive letter.

oldfilename is the name of the file you want to rename.

drive:

indicates the drive where the newfilename is stored. You must include the colon (:) after the drive letter. The drive letter must match the drive letter you entered for the oldfilename.

newfilename is the new name of the file.

Trakker Antares 2400 Family System Manual

Page 131

Chapter 5 - Reader Command Reference

Keypad or Menu:

From the Main Menu, choose System Menu, and then choose File Manager. Choose the drive where you want to rename files. Note: To use the bar code labels from the “Full ASCII Bar Code Chart,” you may need to configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146.

Scan:

Follow these steps: 1 Scan this bar code label: Enter Accumulate Mode / Rename File

*+/...-*

*+/...-*

2 Scan the bar code labels for the file you want to rename. You can scan labels from the “Full ASCII Bar Code Chart” on page 284. The label must use this format: drive:oldfilename,drive:newfilename

3 Scan this bar code label to exit Accumulate mode and rename the file. Exit Accumulate Mode

*-/*

*-/*

Or: You can create your own bar code labels to rename files by creating a bar code in this command format: ...-drive:oldfilename,drive:newfilename

Example:

To rename the file SHIPPING.BIN on drive C to DOCK1.BIN, use this command: ...-c:shipping.bin,c:dock1.bin

Reset Firmware Description: Resets all firmware on the terminal, resets the application, and runs the application. You can use this command to perform a warm boot and restart your application if you are having problems. From Network: -. Keypad or Menu: Scan:

From the main menu, chose System Menu, and then choose Upgrade Firmware. Reset Firmware

*-.* *-.*

Trakker Antares 2400 Family System Manual

111

Page 132

Chapter 5 - Reader Command Reference

Run Program Description: Runs the specified program or application that is stored on the terminal. Note: You cannot store and run applications from the RAM drive (E). From Network: //drive:filename where:

Keypad or Menu:

// is the command to run an application.

drive:

indicates the drive where the application is stored. You must include the colon (:) after the drive letter.

filename is the application you want to run.

From the Main Menu, choose System Menu, and then choose File Manager. Choose the drive where the application is stored. Note: To use the bar code labels from the “Full ASCII Bar Code Chart,” you may need to configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146.

Scan:

Follow these steps: 1 Scan this bar code label: Enter Accumulate Mode / Run Program

*+///*

*+///*

2 Scan the bar code label or labels for the application you want to run. You can scan labels from the “Full ASCII Bar Code Chart” on page 284. The label must use this format: drive:filename

3 Scan this bar code label to exit Accumulate mode and run the application. Exit Accumulate Mode

*-/*

*-/*

Or: You can create your own bar code labels to run applications by creating a bar code in this command format: //drive:filename

Example:

To run the application SHIPPING.BIN, use this command: //c:shipping.bin

112

Trakker Antares 2400 Family System Manual

Page 133

Chapter 5 - Reader Command Reference

Save Configuration in Flash Memory Description: Saves the current configuration in flash memory. When you configure the terminal by scanning bar code labels or sending commands from a network device, the configuration changes are saved in RAM. When you save the configuration to flash memory, the current configuration becomes the active configuration, and it will be used the next time you boot or reset the terminal. From Network: .+1 Keypad or Menu: Scan:

From the Main Menu, choose System Menu, and then choose Store Configuration. Save Configuration in Flash Memory

*.+1* *.+1*

Scanner Trigger On and Off The Scanner Trigger On and the Scanner Trigger Off commands perform the same functions as pulling and releasing the scanner trigger on an external scanner or pushing and releasing the Scan button on a hand-held terminal keypad. After a Scanner Trigger On command is sent, the scanner operates differently depending on the Scanner mode and scanner trigger configuration settings: • If you configure the terminal to use One-Shot Scanner mode and level triggering, the scanner automatically turns off after a good read of a bar code label or after the scanner timeout period elapses. • If you configure the terminal to use Automatic Scanner mode and level triggering, the scanner remains on after a good read of a bar code label. You can use the Scanner Trigger Off command to turn off the scanner, or you can set the Scanner Timeout command to automatically turn off the scanner after it stays on for the period of time set. For help, see “Scanner Mode” on page 228 or “Scanner Trigger” on page 235. Note: Intermec does not recommend that you use a Scanner Trigger On or Scanner Trigger Off command with the Scanner Trigger command set to edge triggering. Description: The Scanner Trigger On command performs the same function as pulling the scanner trigger on an external scanner or pushing the Scan button on a hand-held terminal keypad.

Trakker Antares 2400 Family System Manual

113

Page 134

Chapter 5 - Reader Command Reference

From Network: /. Keypad or Menu:

Not supported

Scan:

Not supported

Description: The Scanner Trigger Off command performs the same function as releasing the scanner trigger on an external scanner or the Scan button on the hand-held terminal keypad. From Network: /% Keypad or Menu:

Not supported

Scan:

Not supported

Set Time and Date Description: Sets the time and date on the terminal. When the terminal receives the time broadcast command from the 9154 or 9161 controller, the command sets the clock on the terminal. You can configure the clock with seconds or without seconds. Use this command only for backward compatibility with the 95XX terminal. In the 95XX terminal documentation, this command was called Enable Clock. If you do not need backward compatibility, use the Time and Date configuration command. For help, see “Time and Date” on page 255. From Network: /+data Acceptable formats for data to set the time and date are: yy/mm/dd:hh:mm:ss yy/mm/dd:hh:mm hh:mm:ss hh:mm Year values (yy) from 00 to 95 are interpreted as 2000 through 2095. Year values from 96 to 99 are interpreted as 1996 through 1999. Keypad or Menu: Example:

Not supported. Set Time and Date to 1:30

*/+1/Z30* */+1/Z30*

Note: To use this reader command, you must configure the terminal to use Code 39 in Full ASCII mode. For help, see “Code 39” on page 146.

114