Page 9

To configure a 2.4 GHz OpenAir radio

Installing the 2102

1. Configure the following parameter from the Quick Start menu:

To install the 2102, you need to perform these tasks:

Parameter

Explanation

• Connect the 2102 to the Ethernet network.

LAN ID (Domain)

All 2.4 GHz devices on the same network must have the same LAN ID to communicate. Set the LAN ID to a number between 0 and 15. The default is 0.

• Mount the 2102. • Apply power to the 2102.

2. Choose the 2.4 GHz OpenAir command from the Quick Start menu and then configure these parameters: Parameter

Explanation

Channel

You can set the channel from 1 to 15. The default is 1.

Subchannel

You can set the subchannel from 1 to 15. The default is 1.

Security ID

All 2.4 GHz OpenAir devices must have the same security ID to communicate. The security ID may be up to 20 characters long. The default is no password or null.

Note: For optimal performance, you may need to set additional parameters. For more information, see the 21XX Universal Access Point Technical Reference Manual.

Saving the Configuration After you configure the 2102, you must save the configuration.

These tasks are described in the remainder of this section.

Connecting the 2102 to the Ethernet Network To connect the 2102 to your Ethernet network, attach one end of a 10BaseT cable to the Ethernet port on the 2102. Attach the other end to your Ethernet network.

Mounting the 2102 The 2102 ships with a mounting bracket so you can mount the 2102 on a wall or ceiling. The following instructions explain how to mount the 2102 using the mounting bracket that ships with it. Install the mounting bracket and 2102 on a sturdy surface in accordance with local building codes. You need the following tools and materials to install the bracket:

• Two #5 or M3 screws. The screws should be appropriate for the surface on which you are mounting the bracket.

To save the configuration 1. From the main menu, choose the Save Configuration command. 2. Disconnect the power and null-modem cables. You are now ready to install the 2102 in your network.

• Drill and drill bit appropriate for the mounting screws • Screwdriver To mount the 2102 to a wall or ceiling 1. Use the mounting bracket as a template to mark the location of the mounting holes on the mounting surface. 2. Drill the mounting holes. 3. Position the bracket on the mounting surface.

16

17

Page 10

Mounting the 2102 to a Wall or Ceiling (continued)

Applying Power to the 2102 1. Plug the power supply into the power port on the 2102. 2. Plug the AC power cord into the power supply.

2102 back panel

Mounting bracket

3. Plug the other end of the AC power cord into an AC power outlet. The 2102 has no On/Off switch, so it boots as soon as you apply power. Your 2102 is now ready to begin transmitting data packets between your end devices and your wired network.

Screw (2 places)

Hook (2 places)

Accessing the 2102 Remotely After you install the 2102 in your network, you can access it remotely using Telnet or a Web browser. You can view the current settings or reconfigure the 2102; however, you must know the IP address of the 2102 to access it remotely. If a DHCP server assigned an IP address to the 2102, you must obtain the IP address from the DHCP server.

Slot (2 places)

Clip

2102G009.eps

4. Using the screws you provided, secure the bracket to the wall. 5. Fit the slots on the back of the 2102 over the hooks on the mounting bracket. 6. Slide the 2102 up slightly and then press on the base of the 2102 until it clicks into the clip at the bottom of the mounting bracket. These accessories are available for the 2102:

• Cubicle bracket kit (Part No. 070366) allows you to mount the 2102 on a cubicle wall.

• Power supply holder kit (Part No. 069893) allows you to secure the power supply to a wall. For more information about mounting options, contact your Intermec representative.

Only one session can be active with the 2102 at a time. If your session terminates abruptly or a new logon screen appears, someone else may have accessed the 2102 or your access may have timed out.

Using Telnet to Access the 2102 To access the 2102 using Telnet, you need a PC that is on the Ethernet network and that is running Telnet software. The following example uses Microsoft Telnet. To establish a Telnet session with the 2102 1. After the 2102 has been powered on and it has completed its boot sequence, open a Telnet session on the PC. 2. Choose Connect, and then choose Remote System. The Connect dialog box appears. 3. In the Host Name field, enter the IP address of the 2102. 4. Click Connect. The logon screen appears. 5. In the Password field, enter the password. The default is Intermec. 6. Press Enter. The Configuration menu appears.

18

19

Page 11

You can now configure the 2102 remotely using Telnet. The same configuration menus that are available through a serial connection are available through the Telnet session. If you are unable to use the arrow keys on your PC keyboard to navigate through the configuration menus, you may need to enable VT100 Arrows.

2102 Specifications This section lists the specifications for the 2102.

Physical Dimensions

14.66 cm x 9.32 cm x 3.53 cm (5.77 in x 3.67 in x 1.39 in)

Weight

232 g (0.51 lb)

To enable VT100 Arrows 1. Choose Terminal from the Telnet toolbar. 2. Choose Preferences. The Terminal Preferences dialog box appears.

Environmental

3. Select VT100 Arrows.

Operating temperature

0°C to +40°C (+32°F to +104°F)

4. Click OK.

Storage temperature

-20°C to +70°C (-4°F to +158°F)

Relative humidity

10% to 90% (non-condensing)

You can now navigate through the configuration menus using the arrow keys on your PC keyboard.

Using a Web Browser to Access the 2102 You can use a Web browser to access the 2102 configuration menus. Note that your session terminates if there is no activity for 15 minutes. To access the 2102 using a Web browser

Network Data rate

10 Mbps (Ethernet)

Filtering rate

14,880 frames per second

Serial port maximum data rate

115,200 bps

SNMP agent

Version 1 RFC 1213

Ethernet interface

10BaseT

Media Access protocol

CSMA/CD

1. Open a Web browser session. 2. In the Address or Location field, enter the IP address of the 2102 and press Enter. The Enter Network Password dialog box appears.

Electrical Electrical rating

~100 to 240V

3. In the User Name field, enter the user name. The default is Intermec.

1.0 to 0.5A

4. In the Password field, enter the password. The default is Intermec.

50 to 60 Hz

5. Press Enter. The Universal Access Point Configuration Web page appears. Several menu options appear on the Configuration Web page. You can configure the 2102, review the changes, write the changes, upgrade the firmware, and reboot the 2102.

20

21

Page 12

Radio Specifications

Default Settings

This section lists the radio specifications.

This section lists the factory default settings.

2.4 GHz OpenAir Radio

Quick Start Menu Defaults

Data rate

1.6 Mbps per channel 800 Kbps fallback rate for extended range

Channels

Parameter Name

Range

Default

Supports 15 independent, non-interfering “virtual channels” (hopping patterns)

IP Address

4 nodes, 0 to 255

0.0.0.0

IP Subnet Mask

4 nodes, 0 to 255

255.255.255.0

Range

Up to 150 m (500 ft) radius indoors Up to 300 m (1000 ft) radius outdoors

LAN ID

0 to 254

0

2.4 to 2.5 GHz (varies by country)

Access Point (AP) Name

0 to 16 characters

Frequency band

(UAP serial number)

Radio type

Frequency hopping, spread spectrum

Radio power output

100 mW (20dBm)

Ethernet Port Configuration Menu Defaults

IEEE 802.11b High Rate Radio

Parameter Name

Range

Default

Data rate

Port Control

Enabled/Disabled

Enabled

Hello Period

1, 2, or 3 seconds

2

INCA Frame Type

DIX/SNAP

DIX

11 Mbps (High), 5.5 Mbps (Medium), 2 Mbps (Standard), 1 Mbps (Low) with automatic fallback for increased range

Channels

11 (North America), 13 (Europe), 4 (France), 1 (Japan)

Range (11 Mbps)

160 m (525 ft) open environment 50 m (165 ft) semi-open environment 24 m (80 ft) closed environment

Frequency band

2.4 to 2.5 GHz (varies by country)

Radio type

Direct sequence, spread spectrum

Radio power output

32 mW (15dBm)

22

2.4 GHz OpenAir Port Configuration Menu Defaults Parameter Name

Range

Default

Port Control

Enabled/Disabled

Enabled

Hello Period

1, 2, or 3 seconds

2

Security ID

0 to 20 characters no password (null)

Node Type

Master/Station

Master

Channel

1 to 15

1

Subchannel

1 to 15

1

Wireless Hops

Enabled/Disabled

Disabled

MAC Configuration

Default/Manual/ Interference/ Throughput

Default

23

Page 13

2.4 GHz OpenAir Port Configuration Menu Defaults (continued)

IEEE 802.11b High Rate Port Configuration Menu Defaults (continued)

Parameter Name

Parameter Name

Range

Default

Manual MAC Parameters

Range

Default

Advanced Configuration

Master Hop Period

100/200/400 ms

200 ms

Medium Reservation

Enabled/Disabled

Disabled

Master Beacon Frequency

1 to 7

2

Distance Between APs

Small/Medium/Large

Large

Master Deferral Slot

Default/1/3/7

Default

Enabled/Disabled

Disabled

Master Fairness Slot

Default/1/3/7

Default

Microwave Oven Robustness

Fragment Size

1 to 1540

310

DTIM Period

1 to 65535

1

Transmit Mode

AUTO/BFSK/QFSK

AUTO

Multicast Rate

Normal Ack Retry

1 to 255

255

2 Mbits (Standard)

Fragmented Ack Retry

1 to 255

255

11 Mbits (High)/ 5.5 Mbits (Medium)/ 2 Mbits (Standard)/ 1 Mbits (Low)

Normal QFSK Retry

1 to 255

255

Transmit Rate Configuration

Fragmented QFSK Retry

1 to 255

255

Transmit Rate

11 Mbits (High)/ 5.5 Mbits (Medium)/ 2 Mbits (Standard)/ 1 Mbits (Low)

11 Mbits (High)

Transmit Rate Fallback

Enabled/Disabled

Enabled

IEEE 802.11b High Rate Port Configuration Menu Defaults Parameter Name

Range

Default

Port Control

Enabled/Disabled

Enabled

Hello Period

1, 2, or 3 seconds

2

Network Name

0 to 32 characters

INTERMEC

Parameter Name

Range

Default

Frequency

Channel 1 to 14, 2400 to 2500 MHz

Channel 3, 2422 MHz

Port Control

Enabled/Disabled

Enabled

Hello Period

1, 2, or 3 seconds

2

WEP Encryption

Enabled/Disabled

Disabled

Mode

Originate If Root/Listen

Listen

IGMP

Enabled/Disabled

Disabled

IGMP Multicast Address

Any Class D multicast IP address

224.0.1.65

WEP Configuration WEP Receive Data

Unencrypted Allowed/ Encryption Required

Encryption Required

WEP Transmit Key

1 to 4

1

WEP Entry Mode

ASCII/hex

ASCII

WEP Key Size

64 Bit/128 Bit

64 Bit

WEP Key 1

5 ASCII characters or 5 hex pairs

80211

INCA/IP Port Configuration Menu Defaults

WEP Default Key Configuration

24

25

Page 14

Network Configuration Menu Defaults

Bridge Configuration Menu Defaults (continued) Parameter Name

Range

Default

Flood Mode

Hierarchical/Universal/ Disabled

Disabled

Outbound to Terminals

Enabled/Disabled

Disabled

Outbound to Secondary LANs

Set Locally/Enabled

Set Locally

Disabled/No Flooding/ Normal Flooding

Disabled

Drop/Pass

Drop

RFC1042/DIX Conversion

Enabled/Disabled

Enabled

RFC1042 Types to pass through

(any valid protocol type)

80 f3 and 81 37

Parameter Name

Range

Default

IP Address

4 nodes, 0 to 255

0.0.0.0

IP Subnet Mask

4 nodes, 0 to 255

255.255.255.0

IP Router

4 nodes, 0 to 255

0.0.0.0

IP Frame Type

DIX/SNAP

DIX

DHCP

Enabled/Disabled/ Enabled (if 0)

Enabled (if IP Address = 0)

DHCP Server Name

0 to 31 characters

(blank)

Auto ARP Minutes

0 to 120

5

ARP Server Mode

Enabled/Disabled

Disabled

Filters

Global Flooding (continued) Unicast

IDRS IDRS IDRS Server Address

4 nodes, 0 to 255

0.0.0.0

IDRS Scope

0 to 15 characters

INTERMEC

Bridge Configuration Menu Defaults Parameter Name

Range

Default

LAN ID

0 to 254

0

Root Priority

0 to 7

1

Ethernet Bridging

Enabled/Disabled

Enabled

Secondary LAN Bridge Priority

0 to 7

0

Secondary LAN Flooding

Disabled/Enabled/ Multicast/Unicast

Disabled

Flood Mode

Hierarchical/Universal/ Disabled

Hierarchical

Outbound to Terminals

Enabled/Disabled

Enabled

Outbound to Secondary LANs

Set Locally/Enabled

Set Locally

INCA/IP IP Multicast Global RF Parameters

Maintenance Menu Defaults Parameter Name

Range

Default

Password

16 characters

Intermec

Web User Name

16 characters

Intermec

Service Password

Enabled/Disabled

Enabled

Global Flooding Multicast

26

27

Page 15

Part No. 070441-001

*070441-001* *070441-001*

28