Page 1
fatermec W%j | Quick Start Guide hoes
ScanPlus 1800 Hand-held Scanner
Page 2
Quick setup
Step 1
Choose your connection: PC keyboard wedge / USB cable ....................... 4 RS-232 C cable......................................................... 6 Other connections ................................................10
Step 2
Select symbologies for your scanner............................ 8
If necessary . . .
Return to the default setup.............................................. 9 Activate the trigger ............................................................ 9 Use the EasySet software for more setup options.. 10 How to use your scanner ................................................ 11 Check reading distances ................................................. 12 Test bar codes...................................................... back cover
3
Page 3
Keyboard wedge or USB (for PC)
Step 1
➎ Select keyboard QWERTY US English
Only do this if you are using a keyboard wedge or USB cable. AZERTY French
➊ System power OFF
QWERTZ German
(keyboard wedge only) QWERTZ Swiss / French
➋
QWERTY Swedish / Finnish
Connect cables: Keyboard wedge cable
QWERTY Italian
USB cable din/mini-din adaptor cable
QWERTY Norwegian
QWERTY Danish
PC wedge cable P/N 0-364037-00
USB cable P/N 3-364038-01
QWERTY Spanish
QWERTY Portuguese parameters (optional) ➏ Customize (*) = default value Postamble = Enter (*)
➌ Scanner power ON
(normally not required)
Postamble = Carriage Return
Postamble = none
➍ System power ON
Postamble = Tab
(keyboard wedge only)
4
5
Page 4
RS-232 C
Step 1
➏ Customize parameters (optional) (*) = default value
Only do this if you are using an RS-232 C cable.
Baud rate 9600 baud (*)
➊ System power OFF
19200 baud
38400 baud
➋ Connect cables Data bits 7 data bits (*) standard RS-232 C cable P/N 0-364032-00 8 data bits
Parity Even parity (*)
➌ Scanner power ON Odd parity
No parity
➍ System power ON Postamble Carriage Return + Line Feed (*)
➎ Read this code
Carriage Return
(standard RS-232 C PC serial port compatible) 9600 baud, 7 data bits, even parity, 2 stop bits, postamble = carriage return + line feed
6
None
7
Page 5
Symbologies
Step 2
Default setup Read this code to reset your scanner to the default configuration
➊ Disable all symbologies
Trigger activation
➋ Select symbology
Important ! Do NOT read these codes if your ScanPlus does not have a trigger.
Code 39
If you read these codes with a non-trigger model your ScanPlus may stop working. If this happens: 1 Disconnect the ScanPlus. 2 Reconnect the ScanPlus while aiming it at the "Default setup" code above. UPC-A, UPC-E, EAN-8, EAN-13 (UPC-A -> EAN-13)
Trigger Read this code to activate the trigger of your scanner Code 128 / EAN 128
UPC-A, UPC-E, EAN-8, EAN-13 (UPC-A -> UPC-A)
Hands-free scanning Read these codes to activate/deactivate automatic hands-free scanning using a scanner stand. Activate hands-free scanning
PDF 417 (1800 PDF only)
Deactivate hands-free scanning
➌ Use the bar codes on the back cover to test your setup 8
9
Page 6
Full setup with EasySet
Using your scanner
This guide allows you to set up your ScanPlus 1800 for most terminal connections and symbologies. If necessary, use the EasySet setup software (on the CD-ROM) for additional configuration possibilities and terminal connections.
➊ System power OFF RS-232 C cable ➋ Connect (P/N 0-364032-00)
"beep" scanner stand P/N 0-360029-00
➌ Scanner power ON
➍ System power ON To read PDF417 codes (ScanPlus 1800 PDF model only) EasySet setup
➎ Read this code
➏ Start EasySet software 10
11
Page 7
Reading distance
Laser warnings (ScanPlus 1800 ST only) The ScanPlus 1800 ST has a maximum laser output of 0.54 mW at 630-680 nm and complies with the following safety standards: USA: CDRH - Class II Laser Product (CFR 21 Subpart J). IEC 825-1 EN 60825-1 - Class 2 Laser Product. These warnings do not apply to the ScanPlus 1800 SR, PDF and VT which are CCD scanners and do not contain a laser.
Typical average reading distances
ScanPlus 1800 SR ScanPlus 1800 PDF Fix these warning labels onto the product if they are not already present.
0 cm - 10 cm (0" - 4")
Collez les étiquettes d’avertissement sur votre produit. Bringen Sie Warnetiketten auf dem Produkt an. Fije la etiqueta de advertencia en el producto. Cole as etiquetas de precaução no equipamento. Un’etichetta di avviso per il laser è da applicare sul prodotto.
ScanPlus 1800 ST 0 cm - 50 cm (0" - 20")
ScanPlus 1800 VT 0 cm - 35 cm (0" - 14")
12
CAUTION – Use of controls or adjustments or performance of procedures other than those specified herein result in hazardous laser light. VORSICHT – Bei einer anders als hier beschriebenen Verwendung der Bedienelemente oder Veränderungen oder einer anderen Ausführung der Arbeitsabläufe entsteht gefährliches Laserlicht. ATTENTION – L’utilisation de contrôles/commandes ou de réglages ou l’exécution de procédures autres que ceux précisés par le présent document provoquent une lumière laser dangereuse.
13
Page 8
Regulatory statements Intermec hereby declares that the ScanPlus 1800 has been tested and found compliant with the below listed standards as required by the EMC Directive 89/336/EEC as amended by 92/31/EEC and by the Low Voltage Directive 73/23/EEC as amended by 93/68/EEC: EN55022 (1992)
EN50082-1 (1998)
EN60950 (1993)
USA: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. It generates, uses and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause interference to radio communications. If this equipment causes interference, the user will be required to correct the interference at the user’s own expense. This equipment complies with the UL 1950 standard. Canada: This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. This equipment complies with the UL 1950 standard. Cet équipement est conforme à la norme UL 1950. Australia-New Zealand: This equipment has been tested and found to conform to the Australian EMC framework concerning Class B digital devices, prescribed by the Australian and New-Zealand standard AS/NZS 3548.
N309
Mexico: Este equipo cumple con la certificatión NOM. The information contained in this document is for informational purposes only and is subject to change without notice. No part of this document may be copied or reproduced in any manner without the prior written permission of Intermec Technologies Corporation. The word Intermec, the Intermec logo, ScanPlus and EasySet are either trademarks or registered trademarks of Intermec. Throughout this document, trademarked names may be used. Rather than put a trademark (™ or ®) symbol in every occurrence of a trademarked name, we state that we are using the names only in an editorial fashion, and to the benefit of the trademark owner, with no intention of infringement. © 2004 Intermec Technologies Corporation All Rights Reserved
North America / Asia Pacific / Latin America • 6001 36th Avenue West, PO Box 4280, Everett, WA 98203-9280 Tel: +1 425 348 2600 • Fax: +1 425 348 2833 • U.S. service and technical support, tel: 1.800.755.5505 • Canadian service and technical support, tel: 1.800.688.7043 Europe / Middle East / Africa • Sovereign House, Vastern Road, Reading RG1 8BT, England Tel: +44 118 987 9400 • Fax: +44 118 987 9401 Internet: http://www.intermec.com E-mail: info@intermec.com Technical Information: http://www.intermec.com
14
15
Page 9
Test barcodes
EAN 13
1234567890128
UPC-A
Wh
Code 39
CODE-39
PDF417 h Intermec Technologies Corporation PDF417 flatermec
Code 128
CODE-128
P/N 0-360049-01