Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 3

Sabre 1551C Decoding Laser Scanner Quick Reference Guide, pages 9 to 16

Pages 9 to 16 of 24

The original document is the PDF (296 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 1551

Page 9

1551C020X (cont.) Reader/Terminal

Cable Connector

Length

Part No.

Intermec J2010, JG2010, 97XX, T242X, T246X, T248X, 5020

10 Pin Modular

25 ft (1.83m)

068414-055

T2455

10 Pin Modular

6 ft (1.83m)

068414-056

T2455

10 Pin Modular

25 ft (7.63m)

068414-057

MaxiLAN CX, MaxiLAN DX, MicroBAR NX, MaxiBAR, T1700, 5900, 6540 and other manufacturer reader/terminal

9 Pin Squeeze D-Sub

6 ft (1.83m)

068414-063

T241X

16 Pin Amp

6 ft (1.83m)

068414-060

RS-232 DCE*

25 Pin Male D-Sub

6 ft (1.83m)

068414-001

RS-232 DCE*

25 Pin Male D-Sub

25 ft (7.71m)

068414-049

RS-232 DTE, 6400, 6550, 5055**

9 Pin Female D-Sub

6 ft (1.83m)

068426

RS-232 DCE*

25 Pin Female D-Sub

6 ft (1.83m)

068414-002

RS-232 DCE**

9 Pin Male D-Sub

6 ft (1.83m)

068414-039

RS-232 DCE*

9 Pin Female D-Sub

6 ft (1.83m)

068414-042

RS-232 DCE*

9 Pin Male D-Sub

6 ft (1.83m)

068414-043

RS-232 DTE**

9 Pin Female D-Sub

20 ft (6.10m)

068414-044

RS-232 DTE*

25 Pin Male D-Sub

6 ft (1.83m)

068414-003

RS-232 DTE*

25 Pin Female D-Sub

6 ft (1.83m)

068414-004

9

Page 10

Co de

39

Ordering Cables (continued) 1551C020X (cont.) Reader/Terminal

Cable Connector

RS-232 DCE**

Length

Part No.

9 Pin Female D-Sub

6 ft (1.83m)

068414-040

RS-232 DTE**

9 Pin Male D-Sub

6 ft (1.83m)

068414-041

RS-232 DTE, 6400, 6550, 5055**

9 Pin Female D-Sub

20 ft (6.10m)

068414-045

RS-232 DCE, 6400, 6550, 5055**

9 Pin Female D-Sub

15 ft (4.60m)

068414-051

MaxiLAN CX, DX, 6540*

9 Pin Female D-Sub

6 ft (1.83m)

068414-042

Apple Mac ADB

Y 4 Pin Mini-DIN

6 ft (1.83m)

068414-024

DEC VT510/520, PS/2 30/50-80

Y 6 Pin Mini-DIN

6 ft (1.83m)

068414-006

Esprit 200, 400

Y 6 Pin Mini-DIN

6 ft (1.83m)

068414-006

IBM 3151, 347X

Y 8 Pin Modular

6 ft (1.83m)

068414-007

IBM 317X, 318X, 319X

5 position DIN

6 ft (1.83m)

068414-030

IBM ThinkPad

6 Pin Mini-DIN

6 ft (1.83m)

068414-025

Intermec 944X, 9430, 95XX

RJ11 Modular

6 ft (1.83m)

068414-011

Intermec 9465/9450, J2050, JG2050

11 Pin Fisher

6 ft (1.83m)

068414-046

Intermec J2010, JG2010, 97XX, T242X, T248X, 5020

10 Pin Modular

6 ft (1.83m)

068414-012

Intermec J2010, JG2010, 97XX, T242X, T248X, T246X, 5020

10 Pin Modular

25 ft (1.83m)

068414-055

1551C070X

10

Page 11

1551C070X (cont.) Reader/Terminal

Cable Connector

Length

Part No.

T2455

10 Pin Modular

6 ft (1.83m)

068414-056

T2455

10 Pin Modular

25 (7.63m)

068414-057

MaxiLAN CX, MaxiLAN DX, MicroBAR NX, MaxiBAR, T1700, 5900, 6540 and other manufacturer reader/terminal

9 Pin Squeeze D-Sub

6 ft (1.83m)

068414-063

Laptops, PS2 style

6 Pin Mini-DIN

6 ft (1.83m)

068414-053

Laptops, PS2 style

6 Pin Mini-DIN

12 ft (3.65m)

068414-054

Mac Power Book Laptop

4 Pin Mini-DIN

6 ft (1.83m)

068414-048

PC XT/AT

Y 5 Pin DIN

6 ft (1.83m)

068414-061

PC XT/AT

Y 5 Pin DIN

15 ft (4.57m)

068414-062

PC XT/AT Single end

5 Pin DIN

6 ft (1.83m)

068414-035

PC XT/AT Single end

5 Pin DIN

12 ft (3.65m)

068414-036

PS2 30/50/60/80

Y 6 Pin Mini-DIN

6 ft (1.83m)

068414-006

PS2 30/50/60/80

Y 6 Pin Mini-DIN

15 ft (4.57m)

068414-038

Wyse*

Y 4 Pin Modular

6 ft (1.83m)

068414-052

Zenith CruisePAD

6 Pin Mini-DIN

6 ft (1.83m)

068414-032

TTL RS232

Use appropriate 1551C02XX Cable

* Requires one of these external power supplies: 100V, 50/60 Hz 120V, 60 Hz (North American plug) 240V, 50 Hz (United Kingdom plug) 230V, 50 Hz (European plug) PS/2 Mouse Cable, Power Pick-Up **Power on pin 9; no power supply required.

Q Q Q Q Q

Part No. 043230 Part No. 047793 Part No. 047794 Part No. 047795 Part No. 590451

11

Page 12

Co de

39

Connecting the 1551C Laser Scanner You can connect the Sabre 1551C scanner to many Intermec products. For a complete list, see “Ordering Cables” earlier in this guide. To connect the scanner 1. Turn off the reader/terminal.

Scanner handle Modular plug

Screw Interface cable

155XQG.002

2. Connect the modular plug on the interface cable into the bottom of the scanner handle. 3. Tighten the screw using a medium-sized, straight-slot screwdriver to secure the plug in the scanner handle. 4. Connect the other end of the cable to the reader/terminal. If you are using a power supply, connect the power supply to a power outlet and the reader/terminal plug.

Note: The cable connector plug for the reader/terminal will vary according to the cable ordered. For more help installing, configuring, and programming your scanner, refer to the Sabre 1551C Decoding Laser Scanner User’s Manual (Part No. 066104) or find the manual on the internet at www.intermec.com.

12

Page 13

Operating the Sabre 1551C Laser Scanner You can use the scanner for hand-held or hands-free scanning.

Hand-Held Scanning Before you start scanning, make sure the power to the reader/terminal is on and all cable connections are secure. To scan bar codes 1. Aim the scanner at a slight angle or pitch to the bar code and press the trigger. To help you center the laser beam on the correct bar code, the scanners with long-range or high-visibility optics have a marker beam that will appear before scanning when you pull the trigger.

*1

23

*

Vertical Reading Angles (Pitch)

155XQG.003

13

Page 14

Co de

39

2. Adjust the scanner distance to the bar code and the position of the laser beam to make sure every bar and space is scanned.

*HI*

*HI*

INCORRECT

CORRECT 155XQRG.006

3. When you get a successful read, the laser beam turns off, the scanner beeps once, and the light turns green.

Hands-Free Scanning You can use your Sabre 1551C laser scanner with a scanner stand for hands-free scanning. To order a scanner stand, see “Accessories for the Scanner” later in this guide. Note: If your scanner stand does not have a small magnet in the holder, you need to upgrade your stand using upgrade kit part number 066799.

Holder

To use the scanner stand 1. Place the scanner handle on the bottom ledge of the holder and then rotate the handle in the holder until it locks into place.

155XQG.005

14

2. Align the scanner and adjust the column height so that the pulsating laser beam covers the entire label on the base of the stand.

Page 15

3. Make sure the scanner is on and the cable is secure and then place a bar code rightside up over the label on the base of the stand.

I *

If you remove the scanner from the stand, it will immediately reset to hand-held scanning. You can scan bar codes by pressing the trigger.

H

*

When you get a successful read, the laser beam turns off, the scanner beeps once, and the light turns green.

155XQG.004

Configuring the Marker Beam This section explains how to configure the marker beam on long-range and high-visibility scanners. Scan one of the following bar codes to turn off the marker beam, set it to appear for 500 milliseconds, or set it to appear for 1.25 seconds. The default setting is 500 milliseconds. Marker Beam Off

Marker Beam On for 500 milliseconds

Marker Beam On for 1.25 seconds

15

Page 16

Co de

39

Configuring for Selected Terminals The next instructions are for configuring the scanner to work with selected popular terminals or computers. If you have a DEC VT510/520, you can plug and play by scanning one of these bar codes: DEC VT 510/520 with PC/AT style keyboard

DEC VT510/520 with LK 411 keyboard

To configure a scanner for use with selected terminals Program Terminal Interface

1. Scan this bar code.

2. Locate your terminal or computer from this next list and scan the two ID number bar codes representing your terminal. Terminal/Computer

First ID Number

Second ID Number

Apple Mac ADB 4

9

(1551C02XX only)

0

4

IBM PC/AT, IBM PS/2 Model 50/60/80

0

3

0

1

DEC VT220/ 320/420

IBM PC/XT

16