The text of a manual · part 9 of 11
Decoding Laser Scanner User's Manual, pages 81 to 90
Pages 81 to 90 of 110
The original document is the PDF (318 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 1551
Page 81
Configuration Command List
Command
Syntax
Select 4683 LASER Emulation
BK
Select 4683 CCD Emulation
BL
Enable Redundant Transmit Feature (used with LASER redundancy)
BM
Disable Redundant Transmit Feature
BN
Set Software Timeout to 1 Second
BO
IBM PS2 Model 57/25 laptop interface
C9
Select Primary Communications Port/Cancel Wand Emulation
CA
Select Wand Emulation (Code 39, Full ASCII)
CB
Select Wand Emulation (Same Code Emulation)
CC
Inverted Serial Communications
CD
Wedge Mode Enable
CE
Select AT Keyboard and Wedge Mode
CF
Select XT Keyboard and Wedge Mode
CG
Select IBM 3151 Terminal
CH
Select DEC VT220 Terminal
CI
Select IBM Primary Table of Key Code
CQ
Select IBM Secondary Table
CR
Select IBM 317X, IBM 318X, IBM 319X
CT
PC/AT German Keyboard
CV
B
Bar Code
B-5
Page 82
Decoding Laser Scanner User’s Manual Command
Syntax
PC/AT French Keyboard
CW
PC/AT United Kingdom
CX
Select IBM PS/2 Mod 57 / 25
CY
Select Data General D216/D217 Terminal
CZ
Select NEC Powermate SX20 Keyboard
C0
Select IBM 3151 With Break Codes
C1
Select Sperry PC With Keytronics Keyboard
C4
Select Unisys B26 Keyboard Wedge
C6
Enable Fast PC-AT Keyboard (Hong Kong)
C7
Enable Link 125 Terminal
C8
Select 300 baud
DA
Select 600 baud
DB
Select 1200 baud
DC
Select 2400 baud
DD
Select 4800 baud
DE
Select 9600 baud
DF
Select 19200 baud
DG
B-6
Bar Code
Page 83
Configuration Command List
Command
Syntax
B
Bar Code
Commands EA to EN are serial data word commands. 7,Low,1
EA
7,High,1
EB
7,Even,1
EC
7,Odd,1
ED
7,Low,2
EE
7,High,2
EF
7,Even,2
EG
7,Odd,2
EH
8,Low,1
EI
8,High,1
EJ
8,Even,1
EK
8,Odd,1
EL
8, no parity,1
EM
8, no parity,2
EN
B-7
Page 84
Decoding Laser Scanner User’s Manual Command
Syntax
Enable Shift Alphanumeric Keys in Wedge Mode
EO
Disable Shift Alphanumeric Keys in Wedge Mode
EP
Enable Shift Lock
ES
Disable Shift Lock
ET
Turn Off the Intercharacter Delay
GA
Set the Intercharacter Delay. Two digit argument is the delay time in milliseconds (00-99).
GB
Turn Off the Interlabel Delay
GC
Set the Interlabel Delay. Two digit argument is the delay time in 100 milliseconds intervals (00-99).
GD
HA to HK are serial communication commands Turn Off All Protocols
HA
Enable XON/XOFF Protocol. All CTS protocols are disabled.
HB
Enable CTS High to Transmit. XON/XOFF is disabled.
HC
Enable CTS Low to Transmit. XON/XOFF is disabled.
HD
Enable External Trigger +. XON/XOFF is disabled
HE
Enable External Trigger -. XON/XOFF is disabled
HF
RTS Always High
HG
B-8
Bar Code
Page 85
Configuration Command List
Command
Syntax
B
Bar Code
HA to HK are serial communication commands (continued) RTS Always Low
HH
RTS Low = Ready to Receive
HI
RTS High = Transmit Ready
HJ
RTS Low = Transmit Ready
HK
Disable Prefix
IA
Set Prefix to STX
IB
Set Prefix to SOH
IC
Disable Unit ID
JA
Enable Unit ID. The arguments are a two digit unit ID number ID’s are in the range (01-99).
JB
Disable Preamble
KA
Set Four Character Preamble. Unused characters are set to Null. The four character hex value is contained in the arguments.
KB
Disable Postamble
LA
Set Four Character Postamble. Unused characters are set to Null. The four character hex value is contained in the arguments.
LB
Set Suffix to None
MA
Set Suffix to ETX
MB
Set Suffix to CR
MC
B-9
Page 86
Decoding Laser Scanner User’s Manual Command
Syntax
Set Suffix to LF
MD
Set Suffix to HT
ME
Set Suffix to CR/LF
MF
Set Suffix to ETB/NULL
MI
Set User Programmable Suffix Character
MJ
Select Full Duplex
NA
Select Half Duplex
NB
Disable Label Buffering
NC
Enable Label Buffering and Power Conservation. Clear the label buffer.
ND
Enable Full Serial Buffering
NE
Enable No Serial Buffering
NF
One Label Buffer
NG
Select Wide (Normal) Scan Angle
NL
Select Narrow (Reduced) Scan Angle
NM
Disable Stand Mode
NN
Enable Stand Mode
NO
Disable Spotter Beam
NP
Enable Spotter Beam. Single digit argument is the marker duration.
NQ
Enable “No Read” Message Option
NX
Disable “No Read” Message Option
NY
B-10
Bar Code
Page 87
Configuration Command List
Command
Syntax
B
Bar Code
Commands OA to OK are for Code 39 only. Disable Code 39
OA
Enable Standard Code 39
OB
Enable Full ASCII Code 39
OC
Disable Modulo 43 Check Character
OD
Enable Modulo 43 Check Character
OE
Disable Transmit of The Start/Stop Characters
OF
Enable Transmit of The Start/Stop Characters
OG
Set Minimum Length. Two digit argument is the length (01-32)
OH
Set Maximum Length. Two digit argument is the length (01-32)
OI
Enable Transmit of Check Character. This command and the next are responsible for controlling the transmission of the check character in Code 39 ONLY when the check character is required for decode. If the Modulo 43 check character is NOT enabled (with command OE), the check character is simply part of the label and is always transmitted.
OJ
Disable Transmit of Check Character
OK
Disable Interleaved 2 of 5
PA
Enable Interleaved 2 of 5 Without Check Digit
PB
B-11
Page 88
Decoding Laser Scanner User’s Manual Command
Syntax
Enable Interleaved 2 of 5 With Check Digit
PC
Set Minimum Length for Interleaved 2 of 5. Two digit argument is the length (02-32). Length must be a multiple of two. Round all entries up to the next even number. Becomes 1st fixed length for 3 fixed length option.
PD
Set Maximum Length for Interleaved 2 of 5. Two digit argument is the length (02-32). Length must be a multiple of two. Round all entries up to the next even number. Becomes 2nd fixed length for 3 fixed length option.
PE
Disable Standard 2 of 5
PF
Enable Standard 2 of 5
PG
Set Minimum Length for Standard 2 of 5. Two digit argument is the length (01-32).
PH
Set Maximum Length for Standard 2 of 5. Two digit argument is the length (01-32).
PI
Disable Interleaved 2 of 5 Check Digit Transmission
PO
Enable Interleaved 2 of 5 Check Digit Transmission
PP
Transmit All Characters of I 2 of 5 Labels
PR
Transmit Only First Eight Characters of I 2 of 5 Labels
PS
B-12
Bar Code
Page 89
Configuration Command List
Command
Syntax
Disable UPC
QA
Enable UPC With Supplements
QB
Enable UPC Without Supplements
QC
Disable UPC Transmit of Number System Digit
QD
Enable UPC Transmit of Number System Digit
QE
Disable Transmit of The UPC Check Digit (UPC-A and UPC-E only).
QF
Enable Transmit of the UPC Check Digit. (UPC-A and UPC-E only)
QG
Disable Expansion of UPC-E
QH
Enable Expansion of UPC-E
QI
Enable EAN Emulation by UPC-A Symbols. Forces UPC-A to be decoded as EAN13.
QJ
Disable EAN Emulation by UPC-A Symbols
QK
Enable UPC-E Only
QL
Disable Second Beep on Supplements
QN
Enable Second Beep on Supplements
QO
Set Up Supplement Retry Counter
QP
Disable UPC-E Transmission of Check Character
QR
Enable UPC-E Transmission of Check Character
QS
B
Bar Code
B-13
Page 90
Decoding Laser Scanner User’s Manual Command
Syntax
Disable UPC-E Transmission of The Number System Digit
QT
Enable UPC-E Transmission of The Number System Digit
QU
Disable UPC-E
QV
Enable UPC-E With Supplements
QW
Enable UPC-E Without Supplements
QX
Disable Supplement Delimiter
QY
Enable Supplement Delimiter
QZ
Disable Mandatory Supplements for UPC/ EAN
Q0
Enable Mandatory Supplements for UPC / EAN
Q1
Disable UPC-E1 Symbology
Q2
Enable All UPC Symbologies (UPC-A, UPC-E0 and -E1)
Q3
Disable EAN
RA
Enable EAN With Supplements
RB
Enable EAN Without Supplements
RC
Disable EAN Transmit of Number System Digit
RD
Enable EAN Transmit of Number System Digit
RE
Disable Transmit of The EAN Check Digit
RF
B-14
Bar Code