Page 53
Programming the 147X
3
Serial Triggering Serial triggering provides a means of sending a serial trigger command to start and stop decoding. When this feature is turned Off, the imager will not respond to serial trigger commands. When Serial Triggering is turned On, the imager requires a serial trigger character to activate scanning and decoding. The imager continues to scan until a bar code is read, the imager times out, or a Trigger Off command is sent. When Serial Triggering is On, the default Trigger On decimal character is 18 (hex 12, DC2), and the default Trigger Off decimal character is 20 (hex 14, DC4). In the Communication tab of Visual Menu, choose Serial Triggering On and enter the Trigger On and Off Characters. Click Default to set Serial Triggering to the factory defaults. Click the Write Settings to Device button ( imager.
) to send the new setting to the
On the “Decimal to Hex to ASCII Conversion Chart” later in this chapter, find the hex characters you want to use to turn the trigger on and off. Locate the decimal values for those characters and scan the 2 digits for each one from the “General Programming Chart” in Appendix B. Scan one of the following bar codes. The default setting is marked with an asterisk (*). On
Off*
Trigger On (see Note)
Trigger Off (see Note)
3-21
Page 54
1470/1471 Imager User’s Manual
Serial Triggering (continued) Trigger Defaults*
Note: A one to three digit decimal number and Save are required after reading this programming bar code. See “Decimal to Hex to ASCII Conversion Chart” later in this chapter and the “General Programming Chart” in Appendix B.
Trigger Timeout Use this selection to set a timeout (in quarter seconds) of the imager’s trigger. Once the imager has timed out, it must be triggered again either serially or manually. For help with serial triggering, see “Serial Triggering” earlier in this chapter. Set the Trigger Timeout to 00 if you don’t want a Trigger Timeout. The default setting is 120 seconds. In the Communication tab of Visual Menu, enter a number from 0 to 120 in the Trigger Timeout (250 ms increments) field. Click the Write Settings to Device button ( send the new setting to the imager.
) to
Or scan the following bar code and then scan one to three number bar codes from the “General Programming Chart” in Appendix B. Set Timeout
3-22
Page 55
Programming the 147X
3
Power Saving Mode Power Saving mode provides control of the imager’s power consumption as follows: •
Low Power draws low (50%) LED current during image capture, allowing only one read attempt for each trigger pull. The imager is less tolerant of hand movement during the read attempt and powers down after the image capture is complete.
•
Medium Power draws a normal LED current during image capture, which enhances motion tolerance. Medium Power attempts to read as long as the trigger is pulled, going into a “doze” (low power) state after each read attempt. The imager powers down 10 seconds after the image capture is complete.
•
Normal Power draws a normal LED current, attempting to read as long as the trigger is pulled or a decode is in process. The imager doesn’t go into a “doze” state after each read attempt but may power down after 2 minutes if Power Hold Mode is turned Off.
In the Imager tab of Visual Menu, choose Low, Medium, or Normal. Click the Write Settings to Device button (
) to send the new setting to the imager.
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). Low Power
Medium Power
Normal Power*
3-23
Page 56
1470/1471 Imager User’s Manual
Power Hold Mode Power Hold On keeps the imager in a ready-to-read state. To conserve power, this selection may be turned Off, and the imager will power down if not used within 2 minutes. When you are ready to use the imager again, restore power by pressing the trigger. In the Imager tab of Visual Menu, choose Hold Power Indefinitely. Click Default to set Power Hold mode to the factory default. Click the Write Settings to Device button (
) to send the new setting to the imager.
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). On
3-24
Off*
Page 57
Programming the 147X
3
LED Power Level This selection allows you to adjust LED brightness. Off is used when no illumination is needed. Low is used if low illumination is sufficient. High (the default) is the brightest setting. In the Imager tab of Visual Menu, enter a number from 10 (lowest intensity) to 100 (highest intensity) in the Aimer Intensity field. Click the Write Settings to Device button (
) to send the new setting to the imager.
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). Off
Low
High*
3-25
Page 58
1470/1471 Imager User’s Manual
LED Flashing When LED Flashing is On, the aiming light comes on when the trigger is pressed. The aiming light stays on until a bar code is decoded or until the trigger is released. If LED Flashing is turned Off, the average current draw is increased and the aiming light won’t illuminate while the imager reads a bar code. In the Imager tab of Visual Menu, choose LED Flashing Off. Click the Write Settings to Device button (
) to send the new setting to the imager.
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). Off
3-26
On*
Page 59
Programming the 147X
3
Aimer Delay Aimer Delay allows a delay time for the operator to aim the imager before the picture is taken. During the delay time, the aiming light will appear, but the LEDs won’t turn on until the delay time is over. In the Imager tab of Visual Menu, enter a number from 0 to 999 in the Aimer Delay (ms) field. Click the Write Settings to Device button ( imager.
) to send the new setting to the
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). 200 milliseconds
400 milliseconds
Off (No Delay)*
3-27
Page 60
1470/1471 Imager User’s Manual
Aimer Interval Aimer Interval turns off the aiming light or programs the aimer to come on at certain intervals when reading bar codes with the imager. You may program the imager to use the aimer Every Read, Every Second Read, or Every Third Read. You may also program the imager to use the aimer every “x” reads, by entering a number from 0 to 999 to indicate “x.” In the Imager tab of Visual Menu, enter a number from 0 to 999 in the Aimer Interval field. Click the Write Settings to Device button ( imager.
) to send the new setting to the
Or scan one of the following bar codes. The default setting is marked with an asterisk (*).
3-28
Off
Every Read*
Every Second Read
Every Third Read
Page 61
Programming the 147X
3
Aimer Interval (continued) Every “X” Reads (see Note)
Note: A one to three digit number and Save are required after reading this programming bar code. See the “General Programming Chart” in Appendix B.
AutoTrigger Two AutoTrigger Modes are available: Scan Stand and Presentation Mode. When an imager is in Scan Stand mode, the LED shines at the bar code on the base of the stand, which tells it to remain idle. To set Scan Stand mode, see “Scan Stand” later in this section. When a different code is presented, the imager is triggered to read the new code. Presentation mode is for those applications where a scan stand will not work, i.e., when large packages must be scanned. To program the device for presentation mode, see “Presentation Mode” later in this section.
Scan Stand This selection programs the imager to work in a Scan Stand. In the Imager tab of Visual Menu, choose Scan Stand On. Click the Write Settings to Device button (
) to send the new setting to the imager.
3-29
Page 62
1470/1471 Imager User’s Manual
Or scan one of the following bar codes. The default setting is marked with an asterisk (*). Off*
On
Scan Stand Bar Code When an imager is in Scan Stand mode, the LED shines at the Scan Stand bar code, which is on the base of the stand. The Scan Stand bar code tells the imager to remain idle. When a bar code is presented that completely covers the Scan Stand bar code but is not the Scan Stand bar code, the imager turns on and decodes it. Scan Stand Bar Code
Scan Stand LED Intensity Scan Stand LED Intensity sets the idle LED intensity when the imager is in Scan Stand mode. When an imager is in Scan Stand mode, the LED shines at the bar code on the base of the stand, which tells it to remain idle. When a different code is presented, the imager is triggered to read the new code. If the imager has difficulty going back to reading the Scan Stand’s fixed code (for instance, in a low lighting situation), you may want to adjust the Scan Stand LED Intensity. A two-digit number between 15 and 75 must be input after the Scan Stand LED Intensity code is scanned. A 15 corresponds to the lowest intensity level, and a 75 corresponds to the highest intensity level. The default setting is 15. Note that when the imager is triggered to read a code, the imager uses the LED power level specified through “LED Power Level” earlier in this chapter.
3-30