Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 5 of 35

1470/1471 Imager User's Manual: Chapter 3 Programming the 147X, pages 33 to 42

Pages 33 to 42 of 316, from 1470/1471 Imager User's Manual

The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Intermec 1470

Page 33

3 Programming the 147X

Page 34

blank

Page 35

Programming the 147X

3

Use this chapter to program the 147X imager.

Introduction This chapter contains the following sections: •

Reset Factory Settings

•

LED Power Level

•

Status Check

•

LED Flashing

•

All Symbologies

•

Aimer Delay

•

Revision Selections

•

Aimer Interval

•

Terminal Interface

•

AutoTrigger

•

Supported Terminals Chart

•

Setting the Beeper

•

Keyboard Country

•

Intercharacter, Interfunction, and Intermessage Delays

•

Keyboard Style

•

Prefix/Suffix Overview

•

Keyboard Modifiers

•

Data Format Editor Overview

•

Keyboard Function Relationships

•

Output Sequence Overview

•

Communication Settings

•

Multiple Bar Codes

•

Serial Triggering

•

No Read

•

Trigger Timeout

•

Print Weight

•

Power Saving Mode

•

Function Code Transmit

•

Power Hold Mode

Note: The Visual Menu screens in this chapter may look different from the screens on your PC. Visual Menu only displays the settings that your imager supports.

3-3

Page 36

1470/1471 Imager User’s Manual

Reset Factory Settings All operating parameters are stored in nonvolatile memory resident in the imager, where they are permanently retained in the event of a power interruption. When you receive your imager, certain operating parameters have already been set. These are the factory defaults. For default charts, see Chapter 7, “Default Charts.” From Visual Menu, click the Factory Default Settings button in the General tab and then click the Write Settings to Device button (

Or scan the following bar code. Default

3-4

).

Page 37

Programming the 147X

3

Status Check You can see the software revision in the General tab of Visual Menu.

Read the Show Software Revision bar code to transmit the software revision level to the host terminal. The software revision will be printed out as “REV_SW: $ProjectRevision: 1.xx $;REV_WA: 31204734-xxx.” Read the Show Data Formats bar code to transmit the existing Data Format Editor formats. One format per line will be printed out. Show Software Revision

Show Data Formats

3-5

Page 38

1470/1471 Imager User’s Manual

All Symbologies If you want to decode all the symbologies allowable for your imager, scan the All Symbologies On code. In Visual Menu, you need to turn on each symbology individually. All Symbologies On

All Symbologies Off

Revision Selections Power PC Revision and Boot Code Revision would not normally be needed unless you have a problem with the imager. A Technical Support Representative may request this information in order to troubleshoot a problem. In Visual Menu, click Power PC Revision or Boot Code Revision.

3-6

Page 39

Programming the 147X

3

Or scan one of the following bar codes. Power PC Revision

Boot Code Revision

Terminal Interface 1470 and 1471 imagers are factory programmed for an RS-232 interface. If this is your interface and you do not need to modify the settings, skip to “Power Saving Mode” later in this chapter to begin programming the imager. If your interface is not a standard RS-232 and you have a keyboard wedge cable, select your terminal interface from the drop down menu in the Interface tab of Visual Menu. Click the Write Settings to Device button (

) to send the new setting to the imager.

Or refer to the “Supported Terminals Chart” later in this chapter and locate the Terminal ID number for your PC. Scan the Terminal ID bar code below, then scan the numeric bar code(s) in the “General Programming Chart” in Appendix B to program the imager for your terminal ID. Scan Save to save your selection. For example, an IBM PS/2 terminal has a Terminal ID of 002. You would scan the Terminal ID bar code, then 0, 0, 2 from the “General Programming Chart” in Appendix B. If you make an error while scanning the digits (before scanning Save), scan the Discard code in the “General Programming Chart” in Appendix B and scan the digits and the Save code again. The factory default for RS-232 imagers is 000; the default for Keyboard Wedge imagers is 003. Terminal ID

Save

3-7

Page 40

1470/1471 Imager User’s Manual

Supported Terminals Chart Terminal

Model(s)

Terminal ID

DEC

PC433 SE (Portable PC)

003

DELL

Latitude (Portable PC)

003

DTK

486 SLC (Portable PC)

003

Fujitsu

Stylistic (Portable PC)

003

HHLC (Code 128 Emulation)

089

IBM

PC XT

001

IBM

PS/2 25, 30, 77DX2

002

IBM

AT, PS/2 30-286, 50, 55SX, 60, 70, 70-061, 70-121, 80

003

IBM

AT Compatibles Keyboard Emulation (Non-wedge)

003

IBM

Thinkpad 360 CSE, 34, 750 (Portable PC)

097

IBM

Thinkpad 365, 755 CV (Portable PC)

003

IBM

AT Thinkpad

106

Midwest

Micro Elite TS 30 PS (Portable PC)

003

Mitak

4022 (Portable PC)

003

Olivetti

M19, M24, M28, M200

001

Olivetti

M240, M250, M290, M380, P500

003

Reliasys

TR 175

003

RS-232 TTL

3-8

000

Televideo

990, 995, 9060

002

Texas Instruments

Extensa 560CD (Portable PC)

003

Toshiba

2600 (Portable PC)

003

Toshiba

Satellite T1960, T2130, CS (Portable PC)

003

Zenith

Z-note (Portable PC)

003

Page 41

Programming the 147X

3

Keyboard Country As a general rule, the following characters are not supported by the imager for countries other than the United States: @ | $ # { } [ ] = / ‘ \ < > ~ Note: If your imager does not support Keyboard Wedge settings, the Keyboard Wedge tab does not appear in Visual Menu. In the Keyboard Wedge tab of Visual Menu, choose the Keyboard Country. Click the Write Settings to Device button (

) to send the new setting to the imager.

3-9

Page 42

1470/1471 Imager User’s Manual

Or scan the Keyboard Country bar code below, then scan the numeric bar code(s) from the “General Programming Chart” in Appendix B, then the Save bar code to program the keyboard for your country. Keyboard Country

Save

Country Code

Scan

Belgium

1

Denmark

8

Finland

2

France

3

Germany/Austria

4

Great Britain

7

Italy

5

Norway

9

Spain

10

Switzerland

6

U.S. (Default)

0

Keyboard Style You can set different Keyboard Styles:

3-10

•

Regular is used when you normally have the Caps Lock key off.

•

Caps Lock is used when you normally have the Caps Lock key on.

•

Shift Lock is used when you normally have the Shift Lock key on. (Not common to U.S. keyboards.)

•

Automatic Caps Lock is used if you change the Caps Lock key on and off. The software tracks and reflects if you have Caps Lock on or off (AT and PS/2 only). This selection can only be used with systems that have an LED that notes the Caps Lock status.