This chapter provides maintenance instructions and explains how to troubleshoot the 147X imager.
Repairs Repairs and/or upgrades to this product are to be performed only by an authorized service center. To contact an authorized service center, call one of the following numbers: •
U.S. service and technical support: 1-800-755-5505
•
Canadian service and technical support: 1-800-668-7043
•
Outside U.S. and Canada: Contact your local Intermec service supplier
Maintenance The 147X imager provides reliable and efficient operation with a minimum of care. Although specific maintenance is not required, the following periodic checks ensure dependable imager operation.
Cleaning the Imager’s Window Reading performance may degrade if the imager’s window is not clean. If the window is visibly dirty or if the imager isn’t operating well, clean the window with a soft cloth or facial tissue dampened with water (or a mild detergent water solution). If a detergent solution is used, rinse with a clean tissue dampened with water only. The imager’s housing may also be cleaned the same way. Caution Do not submerge the imager in water. The imager’s housing is not water-tight. Do not use abrasive wipers or tissues on the imager’s window; abrasive wipers may scratch the window. Never use solvents (alcohol or acetone) on the housing or window; solvents may damage the finish or the window. Conseil Ne pas immerger l’imageur dans l’eau. Le boîtier de l’imageur n’est pas étanche. Ne pas utiliser de chiffons ou serviettes abrasifs sur la fenêtre de l’imageur ; les chiffons abrasifs peuvent rayés la fenêtre. Ne jamais utiliser de solvants (alcool ou acétone) sur le boîtier ou la fenêtre ; les solvants peuvent endommager la couche de finition ou la fenêtre.
9-3
Page 276
1470/1471 Imager User’s Manual
Inspecting Cords and Connectors Inspect the imager’s interface cable and connector for wear or other signs of damage. A badly worn cable or damaged connector may interfere with imager operation. Contact your Intermec representative to order replacement cables. For information on replacing interface cables, see “Replacing the Interface Cable” later in this chapter.
Examining the Imager’s Housing Routinely examine the imager’s housing for signs of damage. A damaged housing may cause the internal components to move and may result in a malfunctioning imager.
Replacing the Interface Cable The standard interface cable is attached to the imager with a 10-pin modular connector. When properly seated, the connector is held in the imager’s handle by a flexible retention tab. The cable is designed to be field replaceable. •
Order replacement cables from your Intermec representative.
•
When ordering a replacement cable, specify the cable part number of the original interface cable.
To replace the 1470 interface cable 1. Turn off the power to the host system. 2. Disconnect the imager’s cable from the terminal or computer. 3. Locate the small hole on the side of the imager’s handle near the base (cable release). 4. Straighten one end of a paper clip. 5. Insert the end of the paper clip into the small hole and press in. This depresses the retention tab, releasing the connector. Pull the connector out of the imager’s handle while maintaining pressure on the paper clip.
Cable release
147XU003.eps
9-4
Page 277
Maintenance and Troubleshooting
9
6. Replace with the new cable. Insert the connector into the opening at the base of the imager’s handle. Press firmly. The connector is “keyed” to go in only one way and clicks into place. To replace the 1471 interface cable 1. Turn off the power to the host system. 2. Disconnect the imager’s cable from the terminal or computer. 3. Insert a small, flat head screwdriver into the slot between the cable and the back end of the housing. 4. Press the screwdriver tip down to depress the retention tab, releasing the connector.
Cable Release
5. Pull the connector out of the imager while maintaining pressure on the screwdriver. 6. Replace with the new cable. Insert the connector into the opening at the base of the imager. Press firmly. The connector is “keyed” to go in only one way, and will click into place.
Troubleshooting The imager automatically performs self-tests whenever you turn it on. If your imager is not functioning properly, review the following Troubleshooting Guide to try to isolate the problem.
Is the power on? Are the illumination LEDs on? If the illumination LEDs in the imager aren’t illuminated, check that • the cable is connected properly.
• the host system power is on (if external power isn’t used).
Is the imager having trouble reading your bar codes? If the imager isn’t reading bar codes well, check that the bar codes • aren’t smeared, rough, scratched, or exhibiting voids.
• aren’t coated with frost or water droplets on the surface.
• are enabled in the imager or in the decoder the imager connects to.