The text of a manual · part 26 of 35
1470/1471 Imager User's Manual: Chapter 5 Using QuickView, pages 235 to 242
Pages 235 to 242 of 316, from 1470/1471 Imager User's Manual
The original document is the PDF (2.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 1470
Page 235
Using QuickView
5
Serial Programming Commands (continued) Selection
Setting
Serial Command
EAN/JAN 8 Addenda Separator
*No Space
EA8ADS0.
Space
EA8ADS1.
EAN/JAN 13
*Default All EAN/ JAN 13 Settings*
E13DFT.
EAN/JAN 13
*On
E13ENA1.
Off
E13ENA0.
*Don’t Transmit
E13CKX0.
Transmit
E13CKX1.
*Off
E13AD20.
On
E13AD21.
*Off
E13AD50.
On
E13AD51.
*Not Required
E13ARQ0.
Required
E13ARQ1.
*No Space
E13ADS0.
Space
E13ADS1.
UPC A
*Default All UPC A Settings*
UPADFT.
UPC A
*On
UPAENA1.
Off
UPAENA0.
*Don’t Transmit
UPACKX0.
Transmit
UPACKX1.
Don’t Transmit
UPANSX0.
*Transmit
UPANSX1.
*Off
UPAAD20.
On
UPAAD21.
*Off
UPAAD50.
On
UPAAD51.
*Not Required
UPAARQ0.
Required
UPAARQ1.
*No Space
UPAADS0.
Space
UPAADS1.
*Default All UPC E0 Settings*
UE0DFT.
EAN/JAN 13 Check Digit
EAN/JAN 13 2 Digit Addenda
EAN/JAN 13 5 Digit Addenda
EAN/JAN 13 Addenda Required
EAN/JAN 13 Addenda Separator
UPC A Check Digit
UPC A Number System
UPC A 2 Digit Addenda
UPC A 5 Digit Addenda
UPC A Addenda Required
UPC A Addenda Separator
UPC E0
5-25
Page 236
1470/1471 Imager User’s Manual
Serial Programming Commands (continued) Selection
Setting
Serial Command
UPC E0
On
UE0ENA1.
*Off
UE0ENA0.
*Don’t Transmit
UE0CKX0.
Transmit
UE0CKX1.
*Don’t Transmit
UE0NSX0.
Transmit
UE0NSX1.
*Don’t Expand
UE0EXP0.
Expand
UE0EXP1.
On
UE1ENA1.
*Off
UE1ENA0.
*Off
UPEAD20.
On
UPEAD21.
*Off
UPEAD50.
On
UPEAD51.
*Not Required
UPEARQ0.
Required
UPEARQ1.
*No Space
UPEADS0.
Space
UPEADS1.
RSS-14
*Default All RSS-14 Settings*
RSSDFT.
RSS-14
On
RSSENA1.
*Off
RSSENA0.
RSS-14 Limited
*Default All RSS-14 Limited Settings*
RSLDFT.
RSS-14 Limited
On
RSLENA1.
*Off
RSLENA0.
RSS-14 Expanded
*Default All RSS-14 Expanded Settings*
RSEDFT.
RSS Expanded
On
RSEENA1.
*Off
RSEENA0.
Minimum
RSEMIN.
Maximum
RSEMAX.
UPC E0 Check Digit
UPC E0 Number System
UPC E0 Version E Expand
UPC E1
UPC E0/E1 2 Digit Addenda
UPC E0/E1 5 Digit Addenda
UPC E0/E1 Addenda Required
UPC E0/E1 Addenda Separator
RSS Expanded Msg. Length
5-26
Page 237
Using QuickView
5
Serial Programming Commands (continued) Selection
Setting
Serial Command
Codablock
*Default All Codablock Settings*
CBFDFT.
Codablock
On
CBFENA1.
*Off
CBFENA0.
Minimum
CBFMIN.
Maximum
CBFMAX.
PDF 417
*Default All PDF 417 Settings*
PDFDFT.
PDF 417
*On
PDFENA1.
Off
PDFENA0.
Minimum
PDFMIN.
Maximum
PDFMAX.
Micro PDF 417
*Default All Micro PDF Settings*
MPDDFT.
Micro PDF 417
*On
MPDENA1.
Off
MPDENA0.
Minimum
MPDMIN.
Maximum
MPDMAX.
Code 49
*Default All Code 49 Settings*
C49DFT.
Code 49
On
C49ENA1.
*Off
C49ENA0.
Minimum
C49MIN.
Maximum
C49MAX.
On
COMENA1.
*Off
COMENA0.
Minimum
COMMIN.
Maximum
COMMAX.
On
NETENA1.
*Off
NETENA0.
*Don’t Transmit
NETCKX0.
Transmit
NETCKX1.
Stacked Symbology Selections
Codablock Msg. Length
PDF 417 Message Length
Micro PDF 417 Message Length
Code 49 Msg. Length
Composite Codes
Composite Msg. Length
Postal Symbology Selections POSTNET Code (USPS)
POSTNET Check Digit
5-27
Page 238
1470/1471 Imager User’s Manual
Serial Programming Commands (continued) Selection
Setting
Serial Command
BPO 4 State Code (BPO)
On
BPOENA1.
*Off
BPOENA0.
On
CANENA1.
*Off
CANENA0.
*Off
KIXENA0.
On
KIXENA1.
On
AUSENA1.
*Off
AUSENA0.
On
JAPENA1.
*Off
JAPENA0.
On
PLENA0.
*Off
PLENA1.
QR Code Settings
*Default All QR Code Settings*
QRCDFT.
QR Code
*On
QRCENA1.
Off
QRCENA0.
Minimum
QRCMIN.
Maximum
QRCMAX.
Data Matrix Settings
*Default All Data Matrix Settings*
IDMDFT.
Data Matrix
*On
IDMENA1.
Off
IDMENA0.
Minimum
IDMMIN.
Maximum
IDMMAX.
MaxiCode Settings
*Default All MaxiCode Settings*
MAXDFT.
MaxiCode
On
MAXENA1.
*Off
MAXENA0.
Minimum
MAXMIN.
Maximum
MAXMAX.
*Off
MAXSCM0.
On
MAXSCM1.
*Default All Aztec Code Settings*
AZTDFT.
Canadian 4 State Code
Dutch Code
Australian 4 State Code
Japanese Postal Code
Planet Code
2D Matrix Symbology Selections
QR Code Message Length
Data Matrix Msg. Length
MaxiCode Msg. Length
SCM Only
Aztec Code Settings
5-28
Page 239
Using QuickView
5
Serial Programming Commands (continued) Selection
Setting
Serial Command
Aztec Code
*On
AZTENA1.
Off
AZTENA0.
Minimum
AZTMIN.
Maximum
AZTMAX.
*Default All VeriCode Settings*
VERDFT.
*On
VERENA1.
Off
VERENA0.
Size A
VERSZA.
Size B
VERSZB.
Size C
VERSZC.
Size D
VERSZD.
Size E
VERSZE.
*Off
TSTMNU0.
On
TSTMNU1.
*Off
2DDIAG0.
On
2DDIAG1.
Aztec Code Msg. Length 1
VeriCode Settings VeriCode
1
VeriCode Size
1
Test Menu
2D Scan Diagnostics
1
VeriCode settings are not available in the standard imager. An imager with VeriCode setting capability can be special ordered from the factory.
5-29
Page 240
1470/1471 Imager User’s Manual
Query Commands Several special characters can be used to query the imager about its settings. ^
What is the default value for the setting(s)?
?
What is the imager’s current value for the setting(s)?
*
What is the range of possible values for the setting(s)? (The imager’s response uses a dash (-) to indicate a continuous range of values. A pipe (|) separates items in a list of non-continuous values.)
Examples of Query Commands Example #1
What is the range of possible values for Codabar Coding Enable? Enter:
cbrena*.
Response:
CBRENA0-1[ACK]
This response indicates that Codabar Coding Enable (CBRENA) has a range of values from 0 to 1 (off and on). Example #2
What is the default value for Codabar Coding Enable? Enter:
cbrena^.
Response:
CBRENA1[ACK]
This response indicates that the default setting for Codabar Coding Enable (CBRENA) is 1 or on. Example #3
What is the imager’s current setting for Codabar Coding Enable? Enter:
cbrena?.
Response:
CBRENA1[ACK]
This response indicates that the imager’s Codabar Coding Enable (CBRENA) is set to 1 or on. Example #4
What are the imager’s settings for all Codabar selections? Enter:
cbr?.
Response:
CBRENA1[ACK], CHK0[ACK], CKX0[ACK], SSX0[ACK], MIN2[ACK], MAX60[ACK], DFT[ACK].
5-30
Page 241
Using QuickView
5
This response indicates that the imager’s Codabar Coding Enable (CBRENA) is set to 1 or on; the Check Character (CHK and CKX) is set to 0 or No Check Character; the Start/Stop Character is set to 0 or Don’t Transmit; the Minimum Message Length (MIN) is 2 characters; the Maximum Message Length (MAX) is 60 characters; and the Default setting (DFT) has no value.
Button Bar The QuickView button bar and the button functions are shown below.
Open file Save file Print active file Display Quick View Information Zoom in image Zoom out image Capture black & white image Capture grayscale image
Start Visual Menu software Display firmware revision Flash a hex file into ROM Display aimer Cancel image capture Capture an image Quarter resolution Half resolution Full resolution 147XU002.eps
The Start Visual Menu software icon only appears if you have Visual Menu software installed. Visual Menu is available free of charge on the CD-ROM that shipped with the 147X imager.
5-31
Page 242
blank