Page 219

Using QuickView

5

Patient Registration Demonstration (continued)

Place Photo Here

Patient ID:890-66-4589 Mason, Theresa 5 Beach Front Drive Pensacola, FL 49607

Place Photo Here

Patient ID:123-45-4569 Ely, Gerald 5 Quarry Rd. Omaha, NE 12345

5-9

Page 220

1470/1471 Imager User’s Manual

Bills of Lading Demonstration Note: This demonstration is appropriate for the 147XB00 only. Multiple linear bar codes may be replaced in a bill of lading/inventory application. In this demonstration, an individual linear code would typically be used for each part number, description, and quantity, as well as for customer and order number information. If linear codes were used for the bill of lading shown below, the user would have to scan 14 individual bar codes before moving on to the next package. Order #: 99999

Intermec Technologies Corp. 6001 36th Avenue West P.O. Box 4280 Everett, WA 98203-9280

Ship to: ABC Company 123 Highway West San Diego, CA 92100 Customer #: Pick Date:

1234567890 March 4, 1998

Part Number

Description

Quantity

3000-12C 6720/B 54/57/UG 42204062

3000PDF SCANNER 54/57/UG CABLE

3 4 3 1

By taking advantage of the enhanced data capacity of PDF 417, the user is able to encode all the required information in a single bar code label. Using the imager and a two-dimensional symbology, the user gets complete information in a single scan. Scan this bar code to display a sample screen for this bill of lading application.

5-10

Page 221

Using QuickView

5

Signature Capture Demonstration Note: This demonstration is appropriate for the 147XB00 only. The signature capture demo is performed by scanning the Aztec bar code below the signature box. The Aztec bar code commands the imager to capture the image of the signature box and its contents and send this image to the host system running QuickView. PAUL’S QUICK MART MAIN ST. NEW YORK, NEW YORK 315-123-4567 1122-3344-5678 THU, MAR 04, 1999 09=34B *** CREDIT CARD *** CARD NO: EXP DATE: CARD TYPE: TR TYPE: APP CODE: REC NO: TOTAL:

00234567899876543 0100 MC – CREDIT SALE 004910 c009 $37.99

Sign

5-11

Page 222

1470/1471 Imager User’s Manual

Snapshot You may also use the 147X to capture an image. Click on Device - Snapshot, or click ) in the button bar to activate this feature.

on the camera icon (

Select the resolution you wish to use for this image, either Full, Half, or Quarter Resolution. (These can also be selected by clicking on the 1, 1/2, or 1/4 buttons (

) in the button bar.)

Note: If the resolution is higher, the image is sharper and the size of the resulting file is larger. Higher resolution images also take longer to process. You must also select whether you wish to capture the image in Gray Scale ( Black & White (

) or in

).

Note: If you need to see exactly what the imager sees (for example, if you are diagnosing a bar code), you should set the image to Black & White. If you want the imager to display illuminated aiming brackets, click on Device Snapshot Properties - Use Aimer During Image Capture, or click on the aimer icon (

) in the button bar.

Pull the imager’s trigger to capture an image. Captured images appear in the QuickView window.

5-12

Page 223

Using QuickView

5

As you move the mouse over the image, the cursor changes to a magnifying glass. Left click to zoom in to the image, right click to zoom out. To save an image file as a bitmap 1. Choose File - Save As. 2. Enter the location and file name you wish to use for this file. 3. Click Save and a bitmap file is saved.

Open COM Port The following procedure explains how to open a COM port that does not have a device attached. To open a COM port 1. Choose File - Open Com Port. This dialog box appears:

2. Click the arrows to select the Baud Rate, Parity, and Data Bits for the COM port you wish to open. 3. Click Open Port and QuickView opens the COM port whether or not there is a device attached. This feature may be beneficial when troubleshooting a device.

5-13

Page 224

1470/1471 Imager User’s Manual

Reporting Firmware Revision To find out what software version the imager is using, choose Device - Report Device Firmware Revision, or click the imager icon (

) in the button bar.

This popup lists the firmware information:

Load New Imager Software The following procedure explains how to load a new software file into the imager’s ROM. To load new imager software 1. Choose Device - Load Firmware File into ROM or click on the lightning flash icon (

) in the button bar.

2. Select the hex file and click Open. QuickView flashes the new software into your imager’s ROM.

5-14

Page 225

Using QuickView

5

Imager Power Settings By default, the imager will power down after 2 minutes of inactivity. If you wish to keep the imager powered up indefinitely, choose Device - Hold Power. To reset the imager to the default power setting, choose Device - Remove Power Hold.

Trigger Settings If you wish to control the imager’s trigger with the software, you can select Device Trigger On or Device - Trigger Off. These settings turn the trigger on and off just as if you were holding the trigger or releasing it manually. This feature may be necessary when working with a fixed device that has no trigger.

RS-232 Serial Commands Choose View - Serial Command Window to display the Command Center window, which allows you to enter serial commands to the imager. Choose View - Scan Data Window to open a window that displays serial data in a text format.

Serial commands are used to program the imager and to query the imager about programming parameters. For a list of the serial programming commands, see “Serial Programming Commands” later in this section. For information about performing queries, see “Query Commands” later in this chapter.

5-15

Page 226

1470/1471 Imager User’s Manual

Using Serial Programming Commands The serial programming commands can be used in place of the programming bar codes listed in Chapter 3. Both the serial commands and the programming bar codes will program the imager. For complete descriptions and examples of each programming command, refer to Chapter 3. To enter a serial command, click in the Enter Menu Command text box and type in the command(s) you wish to use. If you are typing in more than one command, separate the commands with a semicolon (;). Click Send Command to send the command(s) to the imager.

Responses The imager responds to serial commands with one of three responses: ACK

Indicates a good command that has been processed.

ENQ

Indicates a bad command.

NAK

Indicates the command was good, but the entry was out of the allowable range, e.g., an entry for a minimum message length of 100 when the field will only accept 2 characters.

Command Center Buttons

Display All Settings

5-16

Displays the settings currently saved for the imager.

Display Setting Ranges data field parameters.

Displays all the possible serial commands and the allowable

Display Firmware Rev

Displays the software version being used by the imager.