The text of a manual · part 5 of 12
MobileLAN voice System User's Guide: Chapter 2 - Installing the MobileLAN voice System, pages 29 to 36
Pages 29 to 36 of 102, from MobileLAN voice System User's Guide
The original document is the PDF (793 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 071505
Page 29
Installing the MobileLAN voice System
2
Telephone cables are punched down onto the cross-connect blocks as shown in the following demarc block diagrams.
2-Wire Analog or Digital Demarc Block LINE1 LINE 2 LINE 3 LINE 4 LINE 5 LINE 6 LINE 7
Telephone Ports
LINE 8 LINE 9 LINE 10 LINE 11 LINE 12 LINE 13 LINE 14 LINE 15 LINE 16 tip ring tip ring tip ring tip ring tip ring tip ring tip ring tip ring tip ring tip ring tip ring tip ring tip ring tip ring tip ring tip ring
25 PAIR MALE CONNECTOR CABLE TO GATEWAY CONNECTOR A
UNUSED PAIRS DO NOT USE
2-9
Page 30
MobileLAN voice System User’s Guide
Telephony Gateway Installation Before you install the MobileLAN voice telephony gateways, verify the pre-installation requirements and check the equipment at the installation site.
Verify Pre-Installation Requirements Check the site to be sure pre-installation work has been completed correctly. This work includes: •
Location chosen for the telephony gateway is adequate and power is available.
•
Site survey completed to ensure that access point coverage is adequate.
•
Telephone lines for the wireless devices are installed and properly terminated.
•
Dedicated line is available for remote access to diagnostic modem.
•
Telephone system administrator is on-site to program the existing telephone system.
•
(16-port analog only) For each telephony gateway, grounding terminal in the back panel has been electrically connected to earth ground. Consult the NEC and local codes for instructions on making the connection to the ground.
Check Equipment These items must be at the installation site: •
MobileLAN voice telephony gateways
•
AC adapters–one for each telephony gateway
•
Power outlet–accepts the AC adapters
•
IPC cables–one for each telephony gateway (shipped with the gateway)
•
10BaseT cables
•
MobileLANvoice Telephony Gateway Quick Start Guide and MobileLAN voice System User’s Guide
For the telephony gateway (4-port), these items must also be at the installation site:
2-10
•
Demarcation block or modular connectors
•
RJ-11 phone cord
Page 31
Installing the MobileLAN voice System
2
For the telephony gateway (16-port), these items must also be at the installation site: •
Cross-connect block
•
Screws
•
Star washers–two per telephony gateway for static protection
•
ESD bonding straps–one per telephony gateway for static protection
•
25-pair cables
Mounting the Telephony Gateway (16-Port) The telephony gateway can be mounted either horizontally or vertically. To Mount the Gateway… Horizontally
Connector A is… To the right side of the telephony gateway, with labels in correct position.
Mount the Gateways…. On top of one another
Clearance Between Gateways Leave a little more than 0.64 cm (0.25 in) between adjacent telephony gateways, allowing easy removal of the gateways via the keyhole openings on the back panel. Do not leave more than 1.28 cm (0.5 in) spacing or the ESD bonding strap will not fit correctly. To set the desired telephony gateway spacing, leave (2.3 cm (0.9 in) + desired gap) between adjacent mounting holes.
Vertically
At the top of the telephony gateway.
Side by side
Adjacent telephony gateways should be physically touching.
To mount the telephony gateway 1. Using a 1/8-inch drill bit, drill four pilot holes, on 1.84 x12.1 inch centers (approximately equivalent to 1-13/16 inch x 12-1/8 inch). 2. If installing only one telephony gateway, insert the #8x3/4" screws in the pilot holes and tighten, leaving a 0.33 to 0.64 cm (1/8 to 1/4 in) gap from the wall. If installing more than one telephony gateway, install the ESD bonding strap(s) between adjacent gateways: a. Remove the screws from the bottom (vertical mount) or left (horizontal mount) of adjacent telephony gateways.
2-11
Page 32
MobileLAN voice System User’s Guide b. Place the ESD strap over the pilot holes that span two telephony gateways and hold it against the plywood backboard. c. Place the star washer on top of the ESD strap. d. Insert the #8x3/4" screw and tighten to leave 0.33 to 0.64 cm (1/8 to 1/4 in) gap from the wall. e. Repeat for all ESD straps. 3. Position the telephony gateway with Connector A to the right (horizontal) or bottom (vertical). Slide the telephony gateway over the screws until the gateway drops into place in the keyhole opening. 4. Tighten the screws. 5. (Analog only) For each telephony gateway, the grounding terminal in the back panel must be electrically connected to earth ground. Consult the NEC and local codes for instructions on making the connection to the ground.
Connecting the Telephony Gateway This section explains how to connect the telephony gateway by performing these steps: 1. Connect the telephony gateway to demarcation blocks. 2. If necessary, connect multiple telephony gateways together. 3. Connect the telephony gateway to the LAN. 4. Connect the telephony gateway to power.
Connecting the Telephony Gateway to Demarcation Blocks 4-port Connect the RJ-11 connector from the demarcation block to the designated line port (1-4) on each telephony gateway. The following table shows the pinout for the modular RJ-11 connector. Pin
Function - 4-Wire
Function - 2-Wire
1
Transmit to Switch
Not Used
2
Receive from Switch
Transmit/Receive
3
Receive from Switch
Transmit/Receive
4
Transmit to Switch
Not Used
16-port Connect the male RJ-21 connector from the appropriate demarcation block to the designated RJ-21 connector (A or B) on each telephony gateway. Secure the cables using the keeper.
2-12
Page 33
Installing the MobileLAN voice System
2
Connecting Multiple Telephony Gateways You can connect up to four telephony gateways together to increase system capacity. To connect multiple telephony gateways, connect the IPC cable from the IPC OUT port of the first unit to the IPC IN port of the adjacent unit. Repeat until all telephony gateways are connected.
Connecting Telephony Gateways (4-Port) Gateway # 2 IPC
NET L
A
C
E
1
2
3
4
5
RS-232 OUT
IN
Gateway #1 IPC
NET L
A
C
E
1
2
3
4
5
IN
RS-232 OUT
Note: No IPC cable is connected to the IN port of the first unit or to the OUT port of the last unit. You must use the IPC cable that shipped with your telephony gateway.
2-13
Page 34
MobileLAN voice System User’s Guide
Connecting Telephony Gateways (16-Port)
1
2
3
4
5
PWR
OUT
IN IPC
L N K O K
A C T
C O L
STATUS
E R R NETWORK O R
!
CONN B CONN A
Maximum spacing between units 1/2 inch
RS-232
1
2
3
4
5
PWR OUT
IN IPC
L N K O K
A C T
L N K O K
A C T
L N K O K
A C T
C O L
STATUS
E R R NETWORK O R
!
CONN B CONN A
RS-232
1
2
3
4
5
PWR
OUT
IN IPC
C O L
STATUS
E R R NETWORK O R
!
CONN B CONN A
RS-232
1
2
3
4
5
PWR OUT
IN IPC
C O L
E R R NETWORK O R
STATUS
!
CONN B CONN A
RS-232
Note: No IPC cable is connected to the IN port of the first unit or to the OUT port of the last unit. You must use the IPC cable that shipped with your telephony gateway.
2-14
Page 35
Installing the MobileLAN voice System
2
Connecting the Telephony Gateway to the LAN Using an RJ-45 cable, connect the NET (NETWORK) port on each telephony gateway to the connecting port on the same switching Ethernet hub. Each telephony gateway requires a separate Ethernet connection on the same switching hub.
Connecting Power Caution Make sure you use the appropriate Intermec power supply for your country. If you need to order an Intermec power supply, contact your local Intermec representative. Conseil Assurez-vous d’utiliser la source d’alimentation Intermec adéquate pour votre pays. Si vous devez commander une source d’alimentation Intermec, veuillez contacter votre représentant local Intermec. Note: For proper operation, all telephony gateways must be turned on and off at the same time. If your MobileLAN voice system contains more than one telephony gateway, use an outlet strip with a built-in power switch. To connect power 1. Connect the power plug from the AC adapter to the PWR jack on the back panel of the telephony gateway. 2. Plug the AC adapter into a proper AC power source or into an outlet strip. The telephony gateways will cycle through diagnostic testing and the LEDs will blink for about one minute. When the system is ready for use: •
The E LED should be off on each telephony gateway.
•
LED 1 (Status 1) should be blinking on each telephony gateway.
•
LED 5 (Status 5) should be lit on one and only one telephony gateway. If LED 5 is lit on more than one telephony gateway, the gateways are not correctly connected to one another. Check the IPC and network connections.
After the telephony gateways are installed, you must configure the gateway and wireless telephones. For help, see Chapter 3, “Configuring the MobileLAN voice System.”
2-15
Page 36
MobileLAN voice System User’s Guide
2-16