Page 561

Troubleshooting

A

Understanding the Monitor Message Handler Transactions Dialog Box When you start a system trace or a screen mapping trace, the Monitor Message Handler Transactions dialog box appears. As you send transactions from your devices to the hosts, you can view the traces. MH_IN This box records the information that enters the message handler Receive (input) channel. Choose Clear to clear the information in the box. MH_ACK This box records the information that enters the message handler ACK channel. Choose Clear to clear the information in the box. Output (applications) This box records the information that the message handler sends to the applications and devices. Choose Clear to clear the information in the box.

A-67

Page 562

Model 200 Controller User’s Manual

To pause the system trace • Choose Pause. To save the system trace • Choose Save. The results are stored in the D:\USERDATA\NGTRACE.DAT file. To close the Monitor Message Handler Transactions dialog box 1. Move the Monitor Message Handler Transactions dialog box so that you uncover the Trace Configuration dialog box. 2. Choose Stop. The trace stops and the Monitor Message Handler Transactions dialog box closes.

A-68

Page 563

B Helpful Information

Page 564

Model 200 Controller User’s Manual

Page 565

Helpful Information

B

This appendix provides helpful information about system cabling. It also provides procedures for using the controller to verify your network connections, to transfer files, and to configure the TRAKKER Antares terminals.

System Cabling Specifications This table lists the cables you may use to connect your host and your data collection network with your Model 200 Controller. They also list who supplies the cables and any Intermec part numbers. From

To

Cable Type

Supplied by

Intermec Part No.

Ethernet card (10 Mbit)

Network

UTP for 10BaseT

Customer

None

Customer

None

RG-58 coax for 10Base2 50-ohm coax for 10Base5

Ethernet card (100 Mbit)

Network

Token Ring card

Network

RJ-45 to STP

Card vendor

None

Twinaxial card

Network

15 conductor IBM custom

Intermec accessory

589194

Coaxial card

Network

RG-58 coax

Customer

None

SDLC card

Network

25 conductor IBM custom

Customer

None

RF controller card (2-port)

9181 Base Radio Unit

Belden - 1000 ft

Intermec accessory

583326 cable kit w/clamp

Intermec accessory

055003

4-port interface cable

Intermec

063226

Belden - 1000 ft

Intermec accessory

583326 cable kit w/clamp

Intermec accessory

055003

RF controller card (4-port)

9181 Base Radio Unit

B-3

Page 566

Model 200 Controller User’s Manual

System Cabling Specifications (continued) From

To

Cable Type

Supplied by

Intermec Part No.

Model 200 Controller

External modem

DB-25 to DB-9 modem

Intermec

047287

Model 200 Controller

UPS

STP

Intermec

589157

Model 200 Controller

9180 Network Controller

DB-25 to DB-9 null modem

Intermec accessory

047569

Model 200 Controller

9154 CrossBar Controller

DB-25 to DB-9 null modem

Intermec accessory

047569

Model 200 Controller

9161 Port Concentrator

DB-25 to DB-9 null modem

Intermec accessory

047569

B-4

Page 567

Helpful Information

B

Converting Ethernet Addresses to Token Ring MAC Format When configuring the AS/400 host on the Model 200 Controller, the LAN adapter address you specify depends on whether the controller and the host are on the same type of network. If the controller and AS/400 are on different types of networks, you must “byte-flip” the adapter card address.

Steps:

5 2

0 1 0 1

1 0 1 0

A

4

1

Convert to binary.

2

Reverse the order of the binary digits.

3

Convert to hexadecimal.

4

Swap places.

0 0 1 0

0 1 0 0

4

A

200.082

B-5

Page 568

Model 200 Controller User’s Manual

As a shortcut, you can use this table to byte-flip addresses. The table shows what each hexadecimal digit, from 0 to F, becomes when you perform Steps 1 to 3 (from the previous figure). Then you must perform Step 4. Byte Flipped Hexadecimal Equivalents

B-6

0 converts to

0

1 converts to

8

2 converts to

4

3 converts to

C

4 converts to

2

5 converts to

A

6 converts to

6

7 converts to

E

8 converts to

1

9 converts to

9

A converts to

5

B converts to

D

C converts to

3

D converts to

B

E converts to

7

F converts to

F

Page 569

Helpful Information

B

Using the Controller to Verify Your Network Connections You can use the Model 200 Controller to verify it is correctly connected to the downline devices and to your host. You need to start data collection before you can use the controller to send or receive transactions.

Sending Transactions Once you configure the Model 200 Controller, you may want to verify that you have a connection between the controller and a data collection device or you may want to verify you have a connection between the controller and the host application. Use the Send Transaction feature to send a transaction from a source to a destination. When sending a transaction to a data collection device or an application (destination), make sure that your device or application is ready to accept the transaction. If it is not ready, the transaction is written to a Hot Standby file and you will need to clear the Hot Standby file before sending another transaction to the device or application. For help, see “Viewing the Hot Standby Files” in Appendix A.

B-7

Page 570

Model 200 Controller User’s Manual

Field

Description

Value

Default

Source ID (Optional)

This field can contain the name that you want to use as the source of the transaction.

1 to 16 alphanumeric characters

None

Destination ID (Optional)

This field can contain the name of the data collection device that you want to use as the destination of the transaction.

1 to 16 alphanumeric characters

None

Transaction ID (Optional)

This field can contain the transaction ID of the transaction that you want to send to all devices that accept it.

1 to 20 alphanumeric characters

None

Data or System

This field identifies the transaction to be a data or a system transaction.

D, S

D

Data (Optional)

This field contains any data that you want to send with the transaction ID.

1 to 1024 alphanumeric and special characters

None

To verify your connection 1. From the main menu sidebar buttons, choose Start Data Collection. The Start Data Collection message box appears. 2. Choose Start. 3. From the main menu sidebar buttons, choose System Maintenance. The System Maintenance dialog box appears. 4. Select Send Transaction and then choose Start. The Send Transaction dialog box appears. 5. (Optional) In the Source ID field, enter a name that you want to use as the source of the transaction. 6. If you want to send the transaction to one device, in the Destination ID field enter the logical name of the device that you are using to verify the connection. Or, if you want to send the transaction to all the devices that are configured to accept it, in the Transaction ID field enter the unique name of the transaction.

B-8