The text of a manual · part 7 of 9
0100 Access Point User's Manual, pages 61 to 70
Pages 61 to 70 of 88
The original document is the PDF (932 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Intermec 0100
Page 61
Appendix A
A
NET.CFG (continued) This is for the graphics link driver RL2ISA int 15 port 270 channel 13 subchannel 13 domain 7 station_type 2 master_name Test_AP hop_period 1 b_freq 2 s_freq 7 radio_mode 3 bus_mode 2 no_roaming no_repeating bridge ; debug_color frame ethernet_II frame ethernet_802.2 protocol ip 800 ethernet_II protocol arp 806 ethernet_II protocol span 42 ethernet_802.2 LINK DRIVER NI6510 INT 5 PORT 300 DMA 5 frame ethernet_II frame ethernet_802.2 protocol ip 800 ethernet_II protocol arp 806 ethernet_II protocol span 42 ethernet_802.2 PROTOCOL TCPIP ip_address ip_router ip_subnetbits
192.9.200.157 192.9.200.1 24
A-7
Page 62
0100 Access Point User's Manual
The CFG.CFG File for the Access Point This is for the graphics
The following printout is the CFG.CFG file that the Access Point uses. ip_address 192.9.200.24
A-8
Page 63
Appendix B
B B
Appendix
B-1
Page 64
0100 Access Point User’s Manual
B-2
Page 65
Appendix B
B
Understanding the Radio Parameters Access Points easily integrate into your existing network operating system. Each client on your network operates the same as any wired client PC except that wireless units share the same media or airspace. The following RF parameters allow the wireless adapters to share the same airspace effectively. Note: Do not assign two Access Points or ISA cards to the same domain, channel, and subchannel unless you are purposely doing this in a spanning tree. If two wireless adapters have these parameters the same, you will create a loop in the network.
Station Type Master
Alternate
Station
2
1
0
You need to configure each wireless adapter as a master, alternate master, or station. In each subnetwork, one master coordinates communication between various stations. This acting master can be either a master or an alternate master. An alternate master acts as either a master or a station. If an alternate master locates a master, then it acts as a station. If an alternate master cannot locate any other master within range, it acts as a master. For most network operating systems, define the ISA card in the server or Access Point as the master and all clients such as JANUS readers as stations. A setting of 0 indicates the unit is a station; 1 indicates alternate master; 2 indicates master. The Access Point defaults to a station type of 2. For performance considerations regarding the setting of this parameter, refer to Chapter 4, “Helpful Hints and Troubleshooting.”
B-3
Page 66
0100 Access Point User’s Manual
Master Name Master
Alternate
Station
Optional
Optional
N/A
You can use this optional parameter to specify an alphanumeric name of up to 11 characters to simplify the identification of each master in your network.
Channel Master
Alternate
Station
X
X
N/A
Each master can select one of 15 channels to establish communications with stations. The channels are designated 1 through 15, with 1 being the default setting. Wireless products use the surrounding air as the medium to transmit information. Each channel separates communications for each subnetwork to allow for higher data rate transmission capability in the same airspace. Each channel provides the 1.6 Mbps for a maximum total bandwidth of 24 Mbps in a particular area. For networks with multiple masters, set each master to a different channel for optimum performance.
Subchannel Master
Alternate
Station
X
X
N/A
If you need more than 15 masters in the same area, you can change the subchannel to a different value to separate the various networks. The subchannels are designated 1 through 15, with 1 being the default setting.
B-4
Page 67
Appendix B
B
Domain Master
Alternate
Station
X
X
X
To establish communications, all station types must have the same domain number. The domain is a number between 0 and 15, with 0 being the default setting. For larger wireless networks, use the domain to establish roaming subnetworks throughout your building. Only clients with the same domain will roam from one Access Point to another.
Security ID Master
Alternate
Station
X
X
X
To further improve the security of a wireless subnetwork, each RF product requires the same security ID to establish communication.
B-5
Page 68
0100 Access Point User’s Manual
Understanding the Spanning Tree Protocol Parameters The 0100 Access Point meets the IEEE 802.1d Spanning Tree Protocol specification. This protocol handles a complex bridged network (multiple bridges) where loops are created either unintentionally or to provide redundancy in the network. The bridges configure themselves into a spanning tree topology, removing any loops within the network. If you administer a network with more than one bridge, you will probably need to have some understanding of this protocol so that you can configure your bridges for optimum performance. One of the bridges will become the root of the spanning tree. This root is determined by the bridge with the lowest spanning tree priority on the network. This bridge determines when all the bridges will broadcast their priorities, physical addresses, activity states, and other parameters. This communication is sent in “hello packets,” and the root bridge determines the interval between these packets called the “hello time.” Once a root to the tree is established, all other bridges on the network must become branches. The order of the branches is determined by the spanning tree priority, path cost (number of jumps away from the root), and port priority for each bridge and each port on each bridge. Where redundant bridges cause loops in the network, these loops are resolved by one of the bridges becoming inactive. This means the bridge will no longer forward packets of data that are sent to it. If the loops were not resolved, the same packet of data could travel around the network forever. The network’s bridges determine which bridge should become inactive based on several parameters. You can configure these parameters on an Access Point using the configuration program CFG.EXE, or on a network management station that supports the IEEE 802.1d Bridge MIB (RFC 1493).
Spanning Tree Priority This parameter sets the priority of an Access Point in the spanning tree created on the network. Use it to determine the root node and the branches of the tree and to resolve conflicts over which bridge on a network will become inactive when there is a loop. In the event that two bridges have the same priority, the unique physical address breaks the tie. The lower value has the higher priority. For this parameter, you may choose a value of 0 to 65,535, with a default value of 32,768.
B-6
Page 69
Appendix B
B
Bridge Max Age When the Access Point acts as the root, it uses this parameter to determine the maximum amount of time before discarding hello packet data for all bridges on the network. This parameter is specified in seconds between 6 and 40, with a default value of 20.
Bridge Hello Timer When the Access Point acts as the root, it uses this parameter to determine the interval of time between hello packets. If this parameter is set too high, the network will not quickly resolve contention problems. However, if the parameter is set too low, the network will be crowded with hello packet traffic. This parameter is specified in seconds between 1 and 10, with a default value of 2.
Bridge Forward Delay This parameter specifies the amount of time it takes to transition between port states after reset of the Access Point. The state transitions are as follows: • • • • • disabled blocking incoming packets listening for other bridges learning the addresses of other bridges forwarding data
This parameter is specified in seconds between 4 and 30, with a default value of 15.
Aging Time This parameter specifies the time after which the learned physical address of the network node is discarded. This data is dynamically acquired by the Access Point so that it can forward packets properly. This parameter is specified in seconds between 10 and 1,000,000, with a default value of 300.
B-7
Page 70
0100 Access Point User’s Manual
RF Port Priority and Ethernet Port Priority These parameters are used in the spanning tree algorithm to determine the place of the port in the tree as well as to resolve loop contention problems. The lower value has the higher priority. You can set this parameter for both the RF port and the Ethernet port. These parameters range from 0 to 255, with default values of 128.
RF Port Enabled and Ethernet Port Enabled If either port is disabled, the Access Point will not forward data packets to the network through this port. Since there are only two ports on the Access Point, disabling either port would make the entire bridge inactive.
RF Port Path Cost and Ethernet Port Path Cost These parameters specify the cost that is added to the spanning tree for this port of the Access Point. This cost applies only when the Access Point is not the root of the tree and when the port you are setting is the root port of the two Access Point ports. The parameter range is 1 to 65535, with a default value of 100 for the Ethernet port and 625 for the RF port.
B-8