Page 46

Chapter 6

System Parameters Menu Overview

6.1

This chapter explains how change system parameters. These parameters allow you to indicate the download method, set the download port, setup the port, and configure the host port’s auto detect feature. To view a list of current parameter settings, see “Viewing All Parameter Values” on page 21. All system parameters are saved in the public file, sysPara.cfg, which can be read by all applications that reside in the terminal.

Setting the Download Method

6.2

Use this procedure to select IBMEFT, NCREFT, Zontalk, GEMS, or Germany as your download method.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

38

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Using the stylus, tap Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Tap Sys Parameters.

Sys Parameters Download Method Download Port Setup Port

Press [Enter] to select Download Method.

Chapter 6 System Parameters Menu Section 6.1 Overview

Page 47

Download Method IBMEFT NCREFT Zontalk GEMS Germany

Select the method you want. Note: The default is IBMEFT.

Updating

6.3

Selecting the Download Port Use this procedure to select the port you will use for downloading applications.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Using the stylus, tap Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Tap Sys Parameters.

Sys Parameters Download Method Download Port Setup Port

Tap Download Port.

Download Port Port1 Port2 Port3

Ingenico 6780 User’s Guide

Select the port that you want to use as the download port (by default, 1 for Host, 2 for Aux, or 3 for E-NET - Ethernet).

39

Page 48

6.4

Setting Up the Port

6.4.1

Selecting the Download Interface Type Use this procedure to select RS232, RS485, Ethernet, etc. as the interface type for Port1 (Host), Port2 (Aux), or Port3 (Ethernet).

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Using the stylus, tap Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Tap Sys Parameters.

Sys Parameters Download Method Download Port Setup Port

Tap Setup Port.

Download Port Port1 Port2 Port3 Dial Host Port Aux Port

(By default, Port 1 = Host, Port 2 = Aux, Port 3 = E-NET port - Ethernet.)

PortX Interface Type Baud Rate Data Bits PortX Auto Detect Result RS232 RS485

40

Tap Port1, Port2, or Port3.

Press [Enter] to select Interface Type.

Select the communications method you want. If you select Port 1 and Auto Detect Result, the application will detect the communications type of a cable plugged into the selected port and return that information to you.

Chapter 6 System Parameters Menu Section 6.4 Setting Up the Port

Page 49

Tailgate USB Ethernet Dial 3201

6.4.2

Setting the Baud Rate Set the baud rate according to the host requirements.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Using the stylus, tap Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Tap Sys Parameters.

Sys Parameters Download Method Download Port Setup Port

Tap Setup Port.

Setup Port Port1 Port2 Port3 Dial

Tap Port1, Port2, or Port3. (By default, Port 1 = Host, Port 2 = Aux, Port 3 = E-NET port - Ethernet.)

Port X Interface Type Baud Rate Data Bits Stop Bits Baud Rate 19200 38400 57600

Ingenico 6780 User’s Guide

Tap Baud Rate.

Select the appropriate baud rate.

41

Page 50

76800 115200 Updating

Press [Cancel] to return to the previous menu.

Setting the Data Bits

6.4.3

Set the data bits according to the host requirements.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Using the stylus, tap Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Tap Sys Parameters.

Sys Parameters Download Method Download Port Setup Port

Tap Setup Port.

Setup Port Port1 Port2 Port3

Select Port1, Port2, or Port3. (By default, Port 1 = Host, Port 2 = Aux, Port 3 = E-NET port - Ethernet.)

Port X Interface Type Baud Rate Data Bits Stop Bits Data Bits 5 6 7 8

Tap Data Bits.

Select the appropriate data bits value.

Updating

42

Chapter 6 System Parameters Menu Section 6.4 Setting Up the Port

Page 51

6.4.4

Setting the Stop Bits Set the stop bits according to the host requirements.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Using the stylus, tap Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Tap Sys Parameters.

Sys Parameters Download Method Download Port Setup Port

Tap Setup Port.

Setup Port Port1 Port2 Port3

Select Port1, Port2, or Port3. (By default, Port 1 = Host, Port 2 = Aux, Port 3 = E-NET port - Ethernet.)

Set Port X Interface Type Baud Rate Data Bits Stop Bits Stop Bits 1 2

Tap Stop Bits.

Select the appropriate stop bits value.

Updating

Ingenico 6780 User’s Guide

43

Page 52

Setting the Parity

6.4.5

Set the parity according to the host requirements.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Tap Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Using the stylus, tap Sys Parameters.

Sys Parameters Download Method Download Port Setup Port

Tap Setup Port.

Setup Port Port1 Port2 Port3

(By default, Port 1 = Host, Port 2 = Aux, Port 3 = E-NET port - Ethernet.)

Set Port X Interface Type Baud Rate Data Bits Stop Bits Parity Parity None Odd Even

44

Select Port1, Port2, or Port3.

Tap Parity.

Select the appropriate parity.

Chapter 6 System Parameters Menu Section 6.4 Setting Up the Port

Page 53

6.4.6

Defining the LAN Address Use this procedure if you are connecting your terminal to a local area network (LAN) through the Host or Aux port.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Using the stylus, tap Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Tap Sys Parameters.

Sys Parameters Download Method Download Port Setup Port

Tap Setup Port.

Setup Port Port1 Port2

Select Port1 or Port2. (By default, Port 1 = Host, Port 2 = Aux.)

Port X Interface Type Baud Rate Data Bits Stop Bits Parity LAN Address

Tap LAN Address.

LAN Address Old Value: 104 Enter New Value:

Key the appropriate LAN address, then press [Enter].

Ingenico 6780 User’s Guide

45

Page 54

Setting the Retry Count

6.4.7

This option sets the number of times the COM port should retry communications in the event of failure (0 to 10).

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Using the stylus, tap Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Tap Sys Parameters.

Sys Parameters Download Method Download Port Setup Port

Tap Setup Port.

Setup Port Port1 Port2 Port3

46

Select Port1 or Port2. (By default, Port 1 = Host, Port 2 = Aux.)

Port X Interface Type Baud Rate Data Bits Stop Bits Parity LAN Address Retry Count

Tap Retry Count.

Retry Count Old Value: 4 Enter New Value:

Enter the number of times the COM port should retry in the event of failure (0 to 10).

Chapter 6 System Parameters Menu Section 6.4 Setting Up the Port

Page 55

6.4.8

Setting the Response Timeout This option sets the amount of time after which the port should cease waiting for a response, in units of 1/100 of a second.

Display

Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.

Extended Menu Serialnum Inject System Config System Info Supervisor Menu

Using the stylus, tap Supervisor Menu.

Enter Password:

Key password [2] [6] [3] [4], then press [Enter].

Supervisor Menu Change Password Application File Security Sys Parameters

Tap Sys Parameters.

Sys Parameters Download Method Download Port Setup Port

Tap Setup Port.

Setup Port Port1 Port2 Port3

Select Port1, Port2, or Port3. (By default, Port 1 = Host, Port 2 = Aux, Port 3 = E-NET port - Ethernet.)

Port X Interface Type Baud Rate Data Bits Stop Bits Parity LAN Address Retry Count Response TMO

Tap Response TMO (timeout).

Response TMO (10 ms) Old Value: 300 Enter New Value:

Enter an amount of time after which the port should cease waiting for a response, in units of 1/100 of a second.

Ingenico 6780 User’s Guide

47