The text of a manual · part 5 of 15
Ingenico 6780 User's Guide: 4 System Info Menu
Pages 26 to 32 of 119, from Ingenico 6780 User's Guide
The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Ingenico i6780
Page 26
Chapter 4
System Info Menu Overview
4.1
This chapter explains how to navigate through the system info menu to view the following system information: check versions of download files, operating system, SSA, and applications; check security information such as MACing; and view parameter settings.
Finding Version Numbers
4.2
This allows you to look up the current version numbers for hardware, firmware, and software loaded in your terminal.
Display
Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.
Extended Menu Serialnum Inject System Config System Info Supervisor Menu System Info Versions Security Info Versions
Using the stylus, tap System Info.
Press [Enter] to select Versions.
EFTL
XXXX
EFTP
XXXX
TALIF
XX.XX
DIG LOADER
XX.XX.XX
This screen displays the version numbers of the download files (EFTL and EFTP), Talif chip, Digitizer loader and application, operating system (OS), System and Security Application (SSA), maintenance application (MNT APP), and all other applications.
DIG APP
XX.XX.XX
Tap Prev to return to the previous menu.
OS
XX.XX
SSA VAR05
XX.XX
APP1
XX.XX PREV
18
Chapter 4 System Info Menu Section 4.1 Overview
Page 27
4.3
Checking the Security Information This allows you to look up information related to security and key management.
Display
Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.
Extended Menu Serialnum Inject System Config System Info Supervisor Menu System Info Versions Security Info Security Info
Using the stylus, tap System Info.
Tap Security Info.
The security options and serial number display.
Prompt MAC Key: Terminal Based
When you are finished reading it, tap Cancel to return to the previous menu.
Reinject SN: Do Not Erase Keys
Note: Your parameter values may be different.
Prompt MACing: Disable Code MACing: Disable MAC Calculation: Double Length Key Atalla KBK: Disable Startup Verify MACing: Disable PED Mode: Disable Financial Key: App Based Serial Number: XXXXXXXXX Cancel
Ingenico 6780 User’s Guide
19
Page 28
RAM Info
4.4
This allows you to look up information on your terminal’s memory space.
Display
Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.
Extended Menu Serialnum Inject System Config System Info Supervisor Menu System Info Versions Security Info RAM Info Security Info
Using the stylus, tap System Info.
Tap RAM Info.
The security options and serial number display.
Total RAM Size: 0 bytes
When you are finished reading it, tap Cancel to return to the previous menu.
Smallest Free Mem Siz: 0 bytes
Note: Values listed are examples only.
Biggest Free Mem Chun: 0 bytes Backup SRAM Size: 0 bytes Cancel
20
Chapter 4 System Info Menu Section 4.4 RAM Info
Page 29
4.5
Viewing All Parameter Values This menu option allows you to view the current system parameter settings. To change system parameters, see Chapter 6, “System Parameters Menu,” on page 38.
Display
Action Restart the terminal by pressing [1] + [Cancel] + [Enter] simultaneously; while the terminal is starting up, press [1] + [3] simultaneously to access the Extended Menu.
Extended Menu Serialnum Inject System Config System Info Supervisor Menu
Using the stylus, tap System Info.
System Info Versions Security Info View Parameter
Tap View Parameter.
View Parameters Version Info: 1.1 Key Entry Beep: Enable Key Beep Length: Click Key Beep Tone: Low
The current parameter settings display. To scroll down to the next screen, press [+]. When you are finished reading it, press [Cancel] to return to the previous menu. Note: Your parameter values may be different.
Device Type: Signature Capture LCD Contrast: 100% Key Inj Port: COM1 Manufacture ID: INGNAR Device Type ID: I6780N Backlight TMO: 11s.
TMO = timeout
LCD Backlight: 100%
Ingenico 6780 User’s Guide
21
Page 30
COM1 AutoDet Res: RS485 COM1AutoDet On/Off OFF COM1 AutoDet TMO: 500ms COM1 AutoDet Retry: 3 Download Method: IBMEFT Download Port Number: COM1 Download Port Type: RS232 Last download result: No Download Host Port Number: COM1 Aux Port Number: COM2
Press [+] to advance to the next screen.
COM1 Interface Type: RS232 COM1 Baud Rate: 9600 COM1 Data Bits: 8 COM1 Stop Bits: 1 COM1 Parity: NONE COM1 LAN Address: 104 COM1 Retry Times: 3 COM1 Resp TMO: 3000ms
TMO = timeout
COM1 Poll TMO: 3000ms COM1 TurnArd TMO: 3000ms
22
Chapter 4 System Info Menu Section 4.5 Viewing All Parameter Values
Page 31
COM2 Interface Type: RS232 COM2 Baud Rate: 9600 COM2 Data Bits: 8 COM2 Stop Bits: 1 COM2 Parity: NONE COM2 LAN Address: 101 COM2 Retry Times: 3 COM2 Stop Bits: 1 COM2 Parity: NONE COM2 LAN Address: 101 COM2 Retry Times: 3 COM2 Resp TMO: 3000ms
TMO = timeout
COM2 Poll TMO: 3000ms COM2 TurnArd TMO: 3000ms COM3 Interface Type: RS232 COM3 Baud Rate: 19200 COM3 Data Bits: 8 COM3 Stop Bits: 1 COM3 Parity: NONE COM3 Retry Times: NONE
Ingenico 6780 User’s Guide
23
Page 32
COM3 Resp Timeout: 3000ms ETH DHCP NONE/AUTO: AUTO ETH Local IP Add: 0.0.0.0 ETH Local IP Port: 0 ETH Remote IP Add: 0.0.0.0 ETH Remote IP Port: 0 ETH IP Add Mask: 0.0.0.0 ETH Gateway: 0.0.0.0 ETH Primary DNS: 0.0.0.0 ETH Secondary DNS: 0.0.0.0 ETH Domain Name: Dial Phone Num: Modem Speed: 9600 Appl Comment: 0.0.0.0
24
Chapter 4 System Info Menu Section 4.5 Viewing All Parameter Values