The text of a manual · part 16 of 16
Ingenico 6500 User's Guide, pages 121 to 126
Pages 121 to 126 of 126: Download Errors; IBM EFT Troubleshooting
The original document is the PDF (881 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Ingenico 6550 / i6550
Page 121
Chapter 12
Download Errors Error Opening Port
12.1
This error message displays on the computer or cash register. The following sections list possible causes and corresponding solutions.
12.1.1
The communications port that IBMEFTDL is using is already being used by another application Close the other application and run the download file again.
12.1.2
The communications port is not working Try another computer. Ask your Ingenico representative to change the batch file to work with the new communications port. Change to the new communications port, then run the new batch file.
12.1.3
The hardware settings in the Ingenico 6500 have been changed 1. Check the properties of the communications port to make sure that the interrupt request and input/output range has not been changed. In Windows 98 or 2000: a. Right-click My Computer, then select Properties. b. Click the Device Manager tab. c.
From the list, double-click Ports, double-click Communications Ports, and then go to the Resources tab.
2. Ensure the settings for COM1 are the default, as follows: Interrupt Request is 04 Input/Output Range is 03F8 3. Ensure the settings for COM2 are the default, as follows: Interrupt Request is 03 Input/Output Range is 02F8
Ingenico 6500 User’s Guide
113
Page 122
Received 3 NAKs or Timeout in sendVISAPacket()
12.2
This error message displays on the computer or cash register. The following sections list possible causes and corresponding solutions.
12.2.1
There may be a loose connection between the host and the Ingenico 6500 Ensure the cables are securely connected.
12.2.2
The communications port settings and EFT/NCR protocol setting in the Ingenico 6500 may be wrong The following procedure explains how to compare the configuration that you have in your IBMEFTDL file to make sure that it is the same as the default setup configuration in your Ingenico 6500 terminal (for details, see 12.3 Default Setup Configuration on page 98). 1. To find the communication port settings in your IBMEFTDL file, open the download batch file, search for the keyword "ibmeftdl", and find the following parameters:, /b: the number following this parameter is the required RS232 baud rate., /d: the number following this parameter is the required RS232 data bits., /t: the character following this parameter is the required RS232 parity setting. An "n" means none parity, "e" means even, "o" means odd parity. 2. Write these parameters down. 3. Next, go the Ingenico 6500 terminal to read the current settings to see if they are the same. Restart the terminal by pressing [1] + [OK] + [CAN]; while it is restarting, access the Extended Menu by pressing [1] and [3] simultaneously. 4. Select System Info, and then select View Parameter. The screen displays the current download configuration for the port the terminal has configured to do the download, the baud rate, data bits, stop bits, and parity of that port. 5. Compare these settings to the IBMEFTDL parameters that you wrote down in step 2; they should be the same. If not, change them using the following steps. 6. From the Communications menu, press [Can] twice to return to the Supervisor Menu. Enter the password, select System Parameters, and then select Download Method. Select IBMEFT or NCREFT. 7. Press [Can] to return to the System Parameters menu, and then select Download Port. Select the correct download port and correct communication type.
114
Chapter 12 Download Errors Section 12.2 Received 3 NAKs or Timeout in sendVISAPacket()
Page 123
8. Press [Can] to return to the System Parameters menu, and then select Setup Port. Select the port to setup, and select the correct baud rate, data bits, stop bits, and parity. 9. After all the settings are updated, the terminal will update the system parameter setting, when you exit the extended menu, the terminal will reset.
12.3
12.4
Default Setup Configuration Configuration
Default Value
IBMEFT/NCR protocol selection
IBMEFT
Download Port Number
Com1
Download Port Type
RS232
RS232 baud rate
19200
RS232 data bits
8
RS232 parity
No parity
RS232 stop bits
1
Error: Bad Prog. The flash memory in the terminal may not match the flash memory requirement of EFTL file. Contact your account manager to arrange to have the terminal sent in for repair.
12.5
Device already loaded with program x and parameter y This error message displays on the computer or cash register if the Ingenico 6500 has already been upgraded.
12.6
CRC Error The CRC Error message, followed by multiple characters in a string, displays on the Ingenico 6500 to indicate that the Security Module has been compromised. Notate error to report with issue. Notify your Ingenico Project Manager immediately and request RMA number authorization to return unit to an authorized repair facility for recovery.
Ingenico 6500 User’s Guide
115
Page 124
Not Enough DFS Space
12.7
This error occurs during a download if the Ingenico 6500 terminal’s data file system does not have enough space to receive any additional download components. To resolve the error, clean up the DFS to make room for downloads. There are two ways to do this: Use MLDT or Wingload 32 to get the DFS information from the terminal and manually delete any redundant files. Go to the Core Menu (or Production Menu) by restarting the terminal and pressing the top left corner of the screen while the terminal is starting up. Select AdvancedOptions, enter the password, and then select FormatDFS. This method will reformat the data file system and delete all existing data files.
Comm Receive Error
12.8
This error occurs when the terminal doesn’t receive a message from the host within the timeout period. To resolve the error, extend the Response TMO setting in the terminal or host.
116
Chapter 12 Download Errors Section 12.7 Not Enough DFS Space
Page 125
Chapter 13
IBM EFT Troubleshooting This section describes how to resolve error messages that may appear on your Ingenico 6500 device display if using IBMEFTDL.
13.1
Card Read Error1 If the Card Read Error message displays on the device after swiping a card through the MSR: Try swiping the card a few more times, varying the speed at which the card is physically drawn through the reader. Try swiping the card in the reverse direction (i.e., if swiping the card from top to bottom, try swiping the card from bottom to top, front to back: back to front). Make sure that you are swiping the card in a straight line (i.e., make sure the MSR card is always touching the bottom of the MSR track). If none of these actions work, then the MSR card is worn and cannot be read electronically. Enter the card number manually. If the register is reloaded immediately after powering up, the Ingenico 6500 may not come up in the correct state. Signing in at the register and seeing if the Ingenico 6500 display reads “Please Slide Card” can determine this. If it does not (i.e., display continues to read, “Closed”), then perform the same steps as for the next error message, EFT Device Not Available.
13.2
EFT Device Not Available If the EFT Device Not Available message displays on the register, perform the following steps: 1. Check to make sure the Ingenico 6500 is on and is displaying the first prompt screen of your application software. 2. On the register, press the Clear key and select the transaction type again. If the problem persists, continue to step 3. 3. To restart the Ingenico 6500 device, press Cancel + 0 + Enter simultaneously. The Ingenico 6500 restarts and the first prompt screen of the application software displays. 4. On the register, press the Clear key and select either the CREDIT or DEBIT transaction type again.
Ingenico 6500 User’s Guide
117
Page 126
The Ingenico 6500 should now be at the first prompt screen of your application software (i.e., it now reads “Please Slide Card”). If not, sign off the register and then sign on again.
EFT Device Not Available – During Check Authorization
13.3
If the EFT Device Not Available message displays on the register during check authorization: 1. Check to make sure the Ingenico 6500 is on and is displaying the first prompt screen of your application software. 2. On the register, press the Clear key and select the transaction type again. If the problem persists, continue to step 3. 3. To restart the Ingenico 6500 device, press Cancel + 0 + Enter simultaneously. The Ingenico 6500 restarts and the first prompt screen of the application software displays. 4. On the register, press the Clear key and select the CHECK transaction type. The Ingenico 6500 should now be at the first prompt screen of your application software (i.e., it now reads “Please Slide Card”). If not, sign off the register and then sign on again.
118
Chapter 13 IBM EFT Troubleshooting Section 13.3 EFT Device Not Available – During Check Authorization