The text of a manual · part 4 of 16
IDAutomation SC7 USB 2D Scanner Programming Manual: System Control, pages 22 to 29
Pages 22 to 29 of 137, from IDAutomation SC7 USB 2D Scanner Programming Manual
The original document is the PDF (2.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the ID Automation SC7
Page 22
System Control
Scan Scanning output: You can set the image size to a VGA resolution to accommodate older applications that require a smaller image size. When Image VGA is set to On, the resultant image is 640x480 pixels. When Image VGA is Off, the image is 752x480 pixels.
Scanning mode: Manual/Serial Trigger Mode When in manual trigger mode, the scanner scans until a barcode is read, or until the hardware trigger is released. When in serial mode, the scanner scans until a barcode has been read or until the deactivate command is sent. In serial mode, the scanner can also be set to turn itself off after a specified time has elapsed (see Read Time-Out, which follows). Read Time-Out Use this selection to set a time-out (in milliseconds) of the scanner's trigger if the scanner is in manual trigger mode. Once the scanner has timed out, you can activate the scanner by pressing the trigger. After scanning the Read Time-Out barcode, set the time-out duration (from 0-300,000 milliseconds) by scanning digits from the inside back cover, then scanning Save. Default = 0 (infinite, or no time-out).
18
Page 23
Scan Manual Trigger, Low Power (For RS-232 only) The scanner powers down until the trigger is pulled. When the trigger is pulled, the scanner powers up and operates until there is no triggering for the time set with the Low Power Time-Out barcode below. There is a delay of up to one second in operation when the scanner is first triggered, but there is no delay when operating in low power time-out mode. Low Power Time-Out Timer Scan the Low Power Time-Out barcode to change the time-out duration (in seconds). Then scan the time-out duration (from 0-300 seconds) from the inside back cover, and Save. Default = 120 seconds. If the unit remains idle during the low power time-out interval, the unit goes into low power mode. Whenever the trigger is enabled, the low power time-out timer is reset.
Auto-Sense Mode This programs the scanner to work in Auto-sense mode. The LEDs are either off or at the lowest power for ambient conditions until a barcode is presented to the scanner. Then the LEDs turn on automatically to read the code. Auto-sense Mode uses ambient light to detect the barcodes. If the light level in the room is not high enough, Auto-sense Mode may not work properly.
19
Page 24
Scanning Output
VGA Off *VGA On
Scanning Mode
*Manual/Serial Trigger Manual Trigger, Low Power Read Time-Out Low Power Time-Out Auto-sense Mode
Auto-sense LED Behavior after Decode When an scanner is in Auto-sense mode, the LEDs remain on and continue scanning for a short time after a barcode is decoded. If you wish to turn the LEDs off immediately after a barcode is decoded, scan the LEDs Off barcode, below. Default = LEDs On. Auto-sense LED Time-Out When using Auto-sense LED Behavior after Decode, you may want to set the time the LEDs remain off after a decode. To set the duration of this delay, scan the barcode below, then set the time-out by scanning digits (0 - 9,999 ms), then scanning Save. Once the unit has completed this time-out, it will immediately resume scanning. Auto-sense Sensitivity Auto-sense Sensitivity increases or decreases the scanner's reaction time to barcode Auto-sense. To set the sensitivity, scan the Sensitivity barcode, then scan the degree of sensitivity (from 0-20) from the inside back cover, and Save. 0 is the most sensitive setting, and 20 is the least sensitive. Default = 1. 20
Page 25
Scan Hands Free Time-Out The Auto-sense Modes is referred to as “hands free” modes. If the hardware trigger is pulled when using hands free mode, the scanner changes to manual trigger mode. You can set the time the scanner should remain in manual trigger mode by setting the Hands Free Time-Out. Once the time-out value is reached, (if there have been no further trigger pulls) the scanner reverts to the original hands free mode. Scan the Hands Free Time-Out barcode, then scan the time-out duration (from 0-300,000 milliseconds) from the inside back cover, and Save. Default = 5,000 ms.
Auto-sense *LEDs On LEDs Off
LED Time-Out LED Time-Out Duration Sensitivity
Hands Free Time-Out
21
Page 26
Indication Beeper The beeper may be programmed On or Off in response to a good read. Turning this option off, only turns off the beeper response to a good read indication. All error and menu beeps are still audible. Volume The beeper volume codes modify the volume of the beep the scanner emits on a good read. Pitch The beeper pitch codes modify the pitch of the beep the scanner emits on a good read. Duration The beeper duration codes modify the length of the beep the scanner emits on a good read.
Beeper *On Off
Volume Low *Medium
High Off
Pitch Low(1600 Hz)
High (4200 Hz) *Medium (3250 Hz)
22
Page 27
Duration *Normal Beep Short Beep
Indication
LED The LED indicator can be programmed On or Off in response to a good read. Polarity LED Good Read Polarity sets the idle and active states of the LED signal. When set to Active High, the LEDs turn on when the signal shifts from low to high. When set to Active Low, the LEDs turn on when the signal shifts from high to low. If the LED is enabled for a good read, the polarity change takes effect after the next successful decode or a power cycle. If the LED is disabled, a polarity change only takes effect after a power cycle. Note: LED Good Read Polarity sets the LED signal voltage level to either high (Active Low) or low (Active High). This will affect LED-Good Read setting. If the LED has been disabled, make sure it is not turned on accidentally by a polarity change. LED *On Off
Polarity Active High *Active Low
LED Power Level This selection allows you to adjust LED and aimer brightness. Off is used when no illumination is needed. Low is used if low illumination is sufficient. High is the brightest setting. If you have an aimer delay programmed, the aimer will be at 100% power 23
Page 28
during the delay, regardless of the LED Power Level. Note: If you scan the Off barcode, both the aimer and illumination lights turn off, making it difficult to scan barcodes in low light. To turn the LED Power Level back on, move to a brightly lit area and scan either the Low or the High barcode below. Illumination Lights If you want the illumination lights on while reading a barcode, scan the Lights On barcode, below. However, if you want to turn just the lights off, scan the Lights Off barcode. Note: This setting does not affect the aimer light. The aiming light can be set using Aimer Modes. Scanner Time-Out Scanner Time-Out powers down the scanner after the unit has been idle for the specified time. To prevent the scanner from powering down, set this time-out to 0. Scan the barcode below, then set the time-out by scanning digits (from 0 -999,999 ms) from the inside back cover, then scanning Save. Default = 1 ms. LED Power Level Off Low (50%)
*High (100%)
Illumination Light *Lights On Lights Off
Scanner Time-Out
Scanner Time-Out
24
Page 29
Indication Reread Delay This sets the time period before the scanner can read the same barcode a second time. Setting a reread delay protects against accidental rereads of the same barcode. Longer delays are effective in minimizing accidental rereads at POS (point of sale). Use shorter delays in applications where repetitive barcode scanning is required. Reread Delay only works when in Auto-sense Mode. User-Specified Reread Delay If you want to set your own length for the reread delay, scan the barcode below, then set the delay (from 0-30,000 milliseconds) by scanning digits from the inside back cover, then scanning Save.
Reread Delay Short (500 ms) *Medium (750ms) Long (1000 ms) Extra Long (2000 ms)
User-Specified Reread Delay
User-Specified Reread Delay
25