Hypercom's two-page Optimum L4150 Terminal Installation Guide (940366-040 Rev.A, 11/07) for the L4150 multi-lane payment terminal. It shows the ports and cables, how to connect power, the stylus, smart card plug and stand, plus compliance notes and cleaning.

Ports
PUSB+POWER and RS232+POWER standard; USB and 100 BASE T optional p. 2
Power supply
Listed 12-24 Vdc supply rated 1 A or more, marked LPS or Class 2 p. 1
Cables
Powered USB 810349-001 or 810349-002; USB 810371-001; powered RS-232 810346-001 or 810346-002; specialty power 810354-001 or 810355-001 p. 2
Accessories
P1310 PIN Pad P/N 010248-007; Hypercom FPE CD P/N 040343-002; stylus pen; metal stand p. 2
Compliance
The guide lists FCC Part 15 (Class A) and Part 68, UL/cUL Listed (UL 60950), IEC 60950-1, PCI-PED, CISPR 22, RoHS p. 1
Temperature limit
Not to be exposed above 140 °F (60 °C) p. 2

What this manual walks you through

  • Connecting power through the A/C power adapter and the RS232+POWER port p. 2
  • Connecting the Powered USB, USB and 100 BASE T ports p. 2
  • Attaching the stylus pen and fitting the smart card plug p. 2
  • Fitting the metal stand p. 2
  • Choosing a power supply when none was shipped p. 1

Good to know

  • Do not spray water or cleaner into the card slot, smart card reader or rear ports, and never immerse the terminal. p. 1
  • Do not use the terminal if visibly damaged, and do not disassemble, incinerate or crush it. p. 2

Questions this manual answers

What power supply does the Hypercom L4150 need?

A listed 12-24 Vdc supply rated 1 A or more and marked LPS or Class 2, plugged into the RS232+POWER port. p. 1, 2

What ports are on the back of the L4150?

PUSB+POWER and RS232+POWER as standard, with an optional USB port and an optional 100 BASE T port. p. 2

What is the part number of the L4150 powered USB cable?

810349-001 or 810349-002. p. 2

The file

Size and text

Pages2
PDF629 KB
TextThe pages are scans; their text was read by OCR, which may hold reading errors.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Hypercom Optimum L4150 Terminal Installation Guide

The text of page 1, read from a scan by OCR; it may hold reading errors

MULTI-LANEOptimum L4150COMPLIANCE

Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

e FCC Part 15 and Part 68 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The user is cautioned that changes or modifications to the product(s) identified in this manual unless expressly approved by Hypercom could void the user's authority to operate these product(s).

e IC CS-03 e RFID: FCC ID: NVA0708270338 e EN 55022 / EN 550024 / EN 60950 e CE IC: 1204B-0708270338 © AS/NZS 3260 / AS/NZS 3548

e A-tick © CE (Select Models) © C-tick (Select Models)

e UL/cUL Listed (UL 60950) e IEC 60950-1 e PCI-PED

e RoHS e CISPR 22 e WEEE

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

NOTICES

If a power supply was NOT shipped with the Optimum L4150 terminal or you DO NOT have a power supply to use with the Optimum L4150 terminal, use the following guidelines when selecting a suitable power supply:

e Must use a Listed 12-24 Vdc supply rated 1 A or greater ¢ Must be marked “LPS” or “Class 2”

To Clean Terminal:

To Clean 2 Screen:

1 A WARNING
© Do not use industrial strength cleaner or an abrsive cleaner as it may damage or scratch the screen

Terminal Reader

Screen Ports (in the back)

© Do not immerse device in water (or liquid) e Do NOT use spray water or cleaner F 5 . Pray Apply water or mild glass cleaner onto a soft, Apply water or plastic-safe cleaner onto a soft, into the MSR slot, Smart Card Reader lint free cloth and gently wipe terminal screen. lint free cloth and gently wipe terminal. or ports on the back. Warning: Do NOT use industrial strength or an abrasive Warning: Do NOT use spray water or cleaner into the cleaner as it may damage or scratch the screen. MSR slot, Smart Card Reader or ports on the back.

World Headquarters: Hypercom Corporation: 2851 West Kathleen Road | Phoenix, Arizona 85053, USA | Tel: +1.602.504.5000 | Fax: +1.602.504.4655

© 2007 Hypercom Corporation, all rights reserved. Hypercom and Optimum and Design are registered trademarks of Hypercom Corporation. The Hypercom logo is a trademark of Hypercom Corporation. All other products or services mentioned in this document are trademarks, service marks, registered trademarks or registered service marks of their respective owners. 940366-040 Rev.A 11/07

enhieCiaiennaemenaecrnceniess canes PEGA D i

A= OptimuML gisHYPERCOMwww.hypercom.com

NORTH AMERICA | CENTRAL AMERICA | LATIN AMERICA | ASIA/PACIFIC RIM | EUROPE | MIDDLE EAST | AFRICA

NORTH AMERICA | CENT MERICA | LATIN AMERICA | ASIA/PACIFIC RIM | E E | MIDDLE EAST | AFRICA

Page 2 of Hypercom Optimum L4150 Terminal Installation Guide

The text of page 2, read from a scan by OCR; it may hold reading errors

Optimum L4150 Terminal Installation Guide

A WARNING
* Do not use if visibly damaged.
  • Do not expose to temperatures above 140 °F or 60 °C.
  • Do not disassemble.
  • Do not incinerate or crush.
  • Keep out of reach of children and pets.

Power & Cable Connections

2 RS232+POWER port

Labeled

Turn the terminal over (as s ports on the back are:

  • PUSB+POWER port (standard)
  • RS232+POWER port (standard)
  • USB port (optional)
  • 100 BASE T port (optional)

4

jown). Connect Power Cord to A/C Power Adapter. Insert A/C Power Adapter into RS232+ POWER port (as shown). Insert the other end

of the Power Cord into the wall receptacle.

5 USB Port

100 BASE T Port ~“

Insert the cable into the 100 BASE T port (as shown). Note: Port used to interface to another USB device

(for example, a Check Reader).

USB Cable (P/N# 810371-001)

Note: Requires input power.

Powered USB Cable (P/N# 810349-001 or 810349-002)

RS-232 Cable 1 Powered RS-232 Cable PINE ar oo | (PIN# 810346-001 or 810346-002)

Note: Requires input power.

ve ) 7 C )

Equipment Check List, - Optimum L4150

Insert the 12 volt Powered USB cable (optional) into the PUSB+ POWER port (as shown). Note: Port used to interface to another USB port on

the POS

Insert the USB cable into the USB port (as shown).

Power Supply Power Cord (P/N# 870066-002 or (P/N# 810003-007) 87071-002) Note: Requires a Power Supply.

A/C Power AdapterStylus PenStylus Pen Cable Port

Insert the cable end of the stylus pen

(as shown).t Card Plug d|1

Smart Card Receptacle Slot

Specialty Power Cable (P/N# 810354-001 or 810355-001)

Stylus Pen

P/N# 600468-001

Remove smart card plug from wrapper. Insert plug into smart card receptacle slot.

The Optimum L4150 Terminal Instal-lation Guide provides basic terminal setup information.

Note: Images within this guide may not exactly

match your device (e.g., smart card reader and

Regional contactless are optional).

SpecificTP

Additional accessories are available for purchase. Contact your Hypercom Sales Associate for specific options and regional availability.

\ f

Power Cord

When not in use, insert the stylus pen into the holder (as shown).

llation

Turn the terminal over. Insert metal stand into the three stand slots (as shown).

P1310 PIN Pad (P/N# 010248-007)

Stand Adapter

Stylus Pen (P/N# 60058 1-001)

Hypercom FPE CD (P/N# 040343-002)

(P/N# 050335-002)