A Apertures Pen/Mouse Wand Aperture Selection The table below is a handy reference to help you choose the proper aperture size required for the size/type barcode you wish to verify. This data is based on the standard ISO/IEC 15416 Barcode Print Quality Test Specification - Linear Symbols. Aperture Diameter (in .001”)/Aperture Ref. No.
Aperture Diameter (in mm)
"X" Dimension Range (in inches)
03
0,075
0.004 to 0.007
0,102 to 0,178
05
0,125
0.0071 to .013
,0180 to 0,330
"X" Dimension Range (in mm)
10
0,250
0.0131 to 0.025
0,333 to 0,635
20
0,500
0.0251 and larger
0,637 and larger
Note: 6 mil aperture specified for UPC/EAN and RSS. 3 mil and 20 mil aperture available in mouse wand style only. Check your application standard's requirements for specified aperture requirements. If no aperture is specified, use the aperture that is close to, but not larger than, 80% of the narrow element width.
The QC890 Verifier has an Automatic selection feature available ONLY for the internal optics. When using the Automatic selection feature, the verifier automatically selects from a 3, 5, 6, or 10 mil aperture. This selection is determined by the symbology (e.g., EAN/UPC selects 6 mil aperture) or as determine by the internal optics’ ability to calculate the width of the narrow element and select the aperture as determined by the table above.
Quick Check® 890 User’s Guide
A-1
Page 32
A-2
Quick Check® 890 User’s Guide
Page 33
B Menu Setting Barcodes The QC890 barcode verifiers are programmed in the factory for the most common settings. If you need to change these settings, programming is accomplished by scanning the barcodes included in this chapter. An asterisk (*) next to an option indicates the default setting.
Resetting the Standard Product Defaults If you aren’t sure what programming options are in your device, or you’ve changed some options and want the factory settings restored, scan the Standard Product Default Settings barcode below.
Standard Product Default Settings
Illumination Timer Scan the appropriate barcode to set the duration (in seconds) of the illumination. Default = 5 seconds.
3 seconds *5 seconds
15 seconds
Quick Check® 890 User’s Guide
B-1
Page 34
Power Down Timer Note: This option applies to battery operation only. When there is no activity within a specified time period, the QC890 Verifier powers down. Scan the appropriate Power Time-Out barcode to change the time-out duration (in seconds). If there are no scans during the “scanner power time-out timer” interval, the QC890 Verifier goes into power down mode. Whenever a scan occurs, the “scanner power down timer” is reset. Default = 15 minutes
No Power Down Timeout 5 minutes
*15 minutes 60 minutes 120 minutes
B-2
Quick Check® 890 User’s Guide
Page 35
C Symbology Defaults - Operation The default QC890 symbologies and operation are listed below: • Codabar*
• Micro PDF417***
• Code 11**
• MSI***
• Code 16K***
• PDF417***
• Code 39*
• IATA 2 of 5***
• Code 49***
• Regular 2 of 5***
• Code 93*
• Telepen**
• Code 128*
• UPC/EAN*
• RSS (RSS-14, RSS Limited, RSS Expanded)***
• Unrecognized***
• Interleaved 2 of 5*
• Reverse Video***
*
Enabled by default. Can be scanned when disabled.
**
Disabled by default. Can be scanned when disabled.
***
Disabled by default. Cannot be scanned when disabled.