Page 28
Symptoms The unit scans but the data is not correct.
Possible Causes
Solution
The scanner and host Check that the scanner and the may not be configured for host are configured for the the same interface same interface parameters. parameters.
The following item is only relevant for an RS232 interface. The unit powers up OK and scans The com port at the host OK but does not is not working or not communicate configured properly. properly with the host.
Check to make sure that the baud rate and parity of the scanner and the communication port match and the program is looking for “RS232” data.
The unit powers up OK and scans The cable is not OK but does not connected to the correct communicate COM port. properly with the host.
Check to make sure that the cable is connected to the correct COM port.
Characters are being dropped.
Inter-character delay needs to be added to the transmitted output.
Add some inter-character delay to the transmitted output by using the Configuration Guides (PN 00-02544 and 00-05252).
The following item is only relevant for a USB interface. The USB host may not be active.
No LEDs, beep or illumination.
The MS4980 will not operate from hub/host power without host communication.
The unit is not receiving sufficient power to support Verify adequate power is being operation. supplied to the scanner. Refer to the electrical specifications on page 26.
24
Turn on the host device.
Page 29
Design Specifications Operational Light Source:
LED 645 nm ± 7.5 nm
Pulse Duration:
Up to 4 mS (Default)
Maximum Output of LED: Depth of Scan Field:
2.63 mW 40 mm – 300 mm (1.57" – 11.8") for 0.33 mm (13 mil) 40 mm x 30 mm (1.57" x 1.18") @ 40mm (1.57") from Face
Field of View:
Minimum Element Width: Resolution: Infrared Activation Range:
Optional Decode and Imaging Capabilities:
System Interfaces: Print Contrast: Number Characters Read: Beeper Operation: Indicators (LED) Default Settings:
250 mm x 187.5 mm (9.84" x 7.38") @ 300 mm (11.8") from Face 1D
0.127 mm (5 mil)
2D
0.19 mm (7.5 mil)
1280 x 960 Pixels 0 mm (0") face to 254 mm (10") Autodiscriminates all Standard 1-D, GS1 DataBar, PDF417, microPDF, MaxiCode, Data Matrix, QR Code, UCC, EAN Composites, Postals, Aztec (Image Transfer) – BMP, TIFF, or JPEG output on USB and RS232 Interfaces Keyboard Wedge, RS232, USB 20% Minimum Reflectance Difference 4096 Bytes Maximum 7 tones or no beep High Intensity Blue
The unit is active and attempting to scan
Low Intensity Blue
The unit is idle
White
Good Read
Mechanical Depth (D):
74 mm (2.91")
Width (W):
50 mm (1.97")
Height (H):
26 mm (1.02")
Weight:
70 g (2.5 oz.)
Specifications are subject to change without notice.
25
Page 30
Electrical Input Voltage:
5.2 VDC ± 0.25V
Power:
Current:
DC Transformers:
RS232, USB w/Power Jack, Keyboard Wedge
USB Host Powered
Peak
2.1 W (Typical)
1.9 W (Typical)
Operating
1.7 W (Typical)
1.7 W (Typical)
Idle
1.2 W (Typical)
1.2 W (Typical)
Peak
398 mA (Typical)
360 mA (Typical)
Operating
331 mA (Typical)
317 mA (Typical)
Idle
230 mA (Typical)
230 mA (Typical)
Peak Values of at least 1 ms in width.
Class II: 5.2VDC @ 1 A
For Regulatory Compliance Information see pages 37 – 40.
Environmental Temperature:
Humidity: Light Levels: Shock: Contaminants: Ventilation:
Operating = 0°C to 40° (32° to 104°F) Storage = -20°C to 70°C (-4°F to 158°F) 5% to 95% relative humidity, non-condensing Up to 100,000 Lux (9,290 footcandles) Designed to withstand 1.5 m (5 ft.) drops Sealed to resist airborne particulate contaminants None required
Specifications are subject to change without notice.
26
Page 31
Applications and Protocols The model number on each scanner includes the scanner number.
Version Identifier
Scanner
Communication Protocol(s) Interfaces supported include:
MS4980
124
•
RS232 (TXD, RXD, RTS, CTS)
•
Keyboard Wedge
•
USB
USB is configurable for Keyboard Emulation Mode, Bi-Directional Serial Emulation Mode or IBM OEM. The default USB setting is Keyboard Emulation Mode.
The following are the most important selectable options specific to the keyboard wedge. Keyboard Type • •
® *AT (includes IBM PS2 models 50, 55, 60, 80) IBM PS2 (includes models 30, 70, 8556)
Keyboard Country Type • • • • •
*USA Belgian French German Hungarian
• • • • •
Italian Japanese Russian Cyrillic Slovenian Spanish
• • • •
Swiss Swedish/Finnish Turkish United Kingdom
* Indicates a default setting. For information on how to change the default settings, refer to the help files in MetroSet2, the MetroSelect Single-Line Configuration Guide or the Area Imaging Supplemental Configuration Guide.
27
Page 32
28
Page 33
Configuration and Upgrades Configuration Modes The MS4980 has three modes of configuration. •
Bar Codes The MS4980 can be configured by scanning the bar codes included in the MetroSelect Single-Line Configuration Guide or the Area Imaging Supplemental Configuration Guide shipped with the area imager. The manuals are available for download at www.honeywellaidc.com.
•
MetroSet2 This user-friendly Windows-based configuration program allows you to simply ‘point-and-click’ at the desired scanner options. MetroSet2 is available for download at www.honeywellaidc.com.
•
Serial Programming This mode of configuration is ideal for OEM applications. This mode gives the end-user the ability to send a series of commands using the serial port of the host system. The commands are equivalent to the numerical values of the bar codes located in the MetroSelect Single-Line Configuration Guide.
29
Page 34
Upgrading the Firmware The MS4980 scanner is part of Honeywell’s line of scanners with flash upgradeable firmware. The upgrade process requires a new firmware file supplied to the customer by a customer service representative and the MetroSet2 software. A personal computer running Windows 95 or greater with an available RS232 serial or USB port is required to complete the upgrade. Note: Do not use the standard cable supplied with Keyboard Wedge MS4980 interface kits for firmware upgrades. If using USB or RS232 for the upgrade process, the standard USB or RS232 cable provided with the scanner can be used. To upgrade the firmware in the MS4980: 1.
For USB: Plug the scanner into a USB port on the host system. For RS232: Plug the scanner into a serial communication port on the host system.
2.
Start the MetroSet2 software.
3.
Click on the plus sign (+) next to POS Scanners to expand the supported scanner list.
4.
Choose the MS4980 from the list.
5.
Click on the Configure xxx/4980 Scanner button.
6.
For USB: Select the USB interface. For RS232: Select the RS232 interface.
7.
Choose Flash Utility from the options list located on the left side of the screen.
8.
Click on the Open File button in the Flash Utility window.
9.
Locate and open the flash upgrade file.
10. For RS232 Only: Select the COM port the scanner is connected to on the host system. 11. Verify the settings listed in the Flash Utility window. 12. Click on the Flash Scanner button to begin the flash upgrade. 13. A message will appear on the screen when the upgrade is complete.
30
MetroSet2 is available for download, at no additional cost, from www.honeywellaidc.com.
Page 35
Scanner and Cable Terminations Scanner Pinout
Figure 17.
Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
RS232 15-pin, D-type Function Reserved Reserved Reserved Reserved Reserved Ground TXD RXD Reserved Reserved Adapter Power CTS RTS Reserved Reserved
Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Keyboard Wedge 15-pin, D-type Function PC Data KB Clock KB Data Reserved Reserved Ground Reserved Jump to Pin 11 PC Clock Host Power(+5V) Adapter Power Jump to Pin 10 Reserved Reserved Reserved
31
Page 36
USB without Power Jack 15-pin, D-type Pin Function 1 Reserved 2 Reserved 3 Reserved 4 USB D5 USB D+ 6 Ground 7 Reserved 8 Reserved 9 Reserved 10 Host Power(+5V) 11 Jump to Pin 10 12 Reserved 13 Reserved 14 Reserved 15 Reserved
32
Figure 18.
USB with Power Jack 15-pin, D-type Pin Function 1 Reserved 2 Reserved 3 Reserved 4 USB D5 USB D+ 6 Ground 7 Reserved 8 Jump to Pin 11 9 Reserved 10 Host Power(+5V) 11 Adapter Power 12 Reserved 13 Reserved 14 Reserved 15 Reserved