The text of a manual · part 2 of 6
MS4980 Area Imaging Scanner Installation and User's Guide, pages 10 to 18
Pages 10 to 18 of 52
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Honeywell MS-4980
Page 10
6
Page 11
Installation RS232 1.
Turn off the host device.
2.
Plug the 15-pin socket end of the cable into the 15-pin D-Type connector on the MS4980 (see page 4).
3.
Connect the 9-pin D-type connector of the communication cable to the proper COM port of the host device.
4.
Plug the power supply into the power jack on the PowerLink cable.
5.
Check the AC input requirements of the power supply to verify the voltage matches the AC outlet. The outlet must be located near the equipment and be easily accessible.
6.
Connect AC power to the transformer.
7.
The MS4980 will start to initialize. The white and blue LED will alternately fade on and off for approximately three seconds. When the scanner has finished initializing, the unit will flash the white LED three times while simultaneously beeping three times. The low intensity blue LED will remain turned on.
8.
Turn on the host device.
Figure 6.
Installation Note Plugging the scanner into a port on the host system does not guarantee that scanned information will be communicated properly to the host system. Please refer to the MetroSelect Single-Line Configuration Guide or MetroSet2’s help files for instructions on changing the scanner’s factory default configuration. The scanner and host system must use the same communication protocols. See caution on page 5.
7
Page 12
Keyboard Wedge 1.
Turn off the host device.
2.
Plug the 15-pin socket end of the cable into the 15-pin D-Type connector on the MS4980 (see page 4).
3.
Disconnect the keyboard from the host device.
4.
Connect the “Y” ends of the communication cable to the keyboard and keyboard port on the host device. If necessary, use the male/female adapter cable supplied with the scanner for proper connections.
5.
Plug the power supply into the power jack on the PowerLink cable.
6.
Check the AC input requirements of the power supply to verify the voltage matches the AC outlet. The outlet must be located near the equipment and be easily accessible.
Figure 7.
7.
Connect AC power to the transformer.
8.
The MS4980 will start to initialize. The white and blue LED will alternately fade on and off for approximately three seconds. When the scanner has finished initializing, the unit will flash the white LED three times while simultaneously beeping three times. The low intensity blue LED will remain turned on.
9.
Turn on the host device. The scanner will automatically reboot after host device is turned on.
Important Note Plugging the scanner into a port on the host system does not guarantee that scanned information will be communicated properly to the host system. Please refer to the MetroSelect Single-Line Configuration Guide or MetroSet2’s help files for instructions on changing the scanner’s factory default configuration. The scanner and host system must use the same communication protocols. See caution on page 5. 8
Page 13
USB (Powered by the Host Device) 1.
Turn off the host device.
2.
Plug the 15-pin socket end of the USB cable into the 15-pin D-Type connector on the MS4980 (see page 4).
3.
Plug the USB end of the cable into the host’s USB port.
4.
Turn on the host device.
5.
The MS4980 will start to initialize. The white and blue LED will alternately fade on and off for approximately three seconds. When the scanner has finished initializing, the unit will flash the white LED three times while simultaneously beeping three times. The low intensity blue LED will remain turned on. The scanner will automatically reboot after first initialization.
Figure 8.
Installation Note Plugging the scanner into a port on the host system does not guarantee that scanned information will be communicated properly to the host system. Please refer to the MetroSelect Single-Line Configuration Guide or MetroSet2’s help files for instructions on changing the scanner’s factory default configuration. The scanner and host system must use the same communication protocols. See caution on page 5.
9
Page 14
USB (Powered by External Power Supply) 1.
Turn off the host device.
2.
Plug the 15-pin socket end of the cable into the 15-pin D-Type connector on the MS4980 (see page 4).
3.
Plug the USB end of the cable into the host’s USB port.
4.
Plug the power supply into the power jack on the PowerLink cable.
5.
Check the AC input requirements of the power supply to verify the voltage matches the AC outlet. The outlet must be located near the equipment and be easily accessible.
6.
Connect AC power to the transformer.
7.
The MS4980 will start to initialize. The white and blue LED will alternately fade on and off for approximately three seconds. When the scanner has finished initializing, the unit will flash the white LED three times while simultaneously beeping three times. The low intensity blue LED will remain turned on.
8.
Turn on the host device. The scanner will automatically reboot after host device is turned on.
Figure 9.
Installation Note Plugging the scanner into a port on the host system does not guarantee that scanned information will be communicated properly to the host system. Please refer to the MetroSelect Single-Line Configuration Guide or MetroSet2’s help files for instructions on changing the scanner’s factory default configuration. The scanner and host system must use the same communication protocols. See caution on page 5.
10
Page 15
Mounting Specifications The MS4980 has three M3 x 0.5 mm threaded inserts on the bottom of the scanner for mounting with screws.
Figure 10.
11
Page 16
Mounting General Guidelines •
Avoid specular reflections, caused by ambient and internal light sources.
•
The bar code should be slightly off perpendicular to the axis of the scanner.
•
To reduce specular reflections the skew angle can vary significantly depending on the application such as: ambient illumination sources, code size and code type.
•
Excessive angles should be avoided.
•
Other factors, such as surface qualities, mounting distances, secondary windows and external illumination can easily impact these recommendations.
•
If a secondary window is used, the window should be mounted as close to the front of scanner as possible at a 90° angle to the optical axis to avoid specular reflections.
•
For secondary windows, Honeywell recommends the following: o
Optical quality glass o
Anti-reflective coating on both sides o
>95% transmission in the nominal 650nm wavelength
•
A skew angle of 15° to 20° between the normal of the bar code’s surface and the optical axis of the imager is sufficient to avoid specular reflections.
•
Avoid pitch angles above 15° to 20° to prevent code compression.
Figure 11.
12
Page 17
Operation Modes of Operation The MS4980 supports two standard modes of operation for scanning bar codes, automatic activation and manual activation scanning. Scanning while in the automatic activation mode can occur in either one of two configurable options, pass-through or presentation. Both the pass-through and the presentation options are enabled by default. With the default configuration, the scanner operates in the pass-through state for 300 ms and then changes to the presentation state for additional decoding capability.
Automatic Activation Mode Pass-through Scanning - Decodes ONLY 1D and PDF bar codes Scanning Method: 1.
Pass the bar code through the active scan area to scan, decode and send data
Presentation Scanning - Decodes ALL 1D, PDF and 2D matrix codes Scanning Method: 1.
Place the object in the IR activation range
2.
Hold the object’s bar code in front of the scan window within the active scan area to scan, decode and send data
The MS4980 requires a stand-alone 5V power supply for pass-through capabilities to function.
Default configuration recommended for optimum scan performance.
13
Page 18
Manual Activation Decodes ALL 1D, PDF and 2D matrix codes Scanning Method: 1.
Press the button one time to activate linear targeting.
2.
Align the linear targeting line over the desired bar code. Note: When scanning 1D programming bar codes, the bar code must be presented to the scanner in the correct orientation, see Figure 12. PDF and 2D matrix codes may be presented in any orientation.
Figure 12. 1D Programming Bar Code Orientation
3.
Press the button a second time to decode and send the data.
4.
The unit will return to the default presentation mode either by the default time length or by double clicking the button.
Note: Decoding and functional capability of the unit is restricted through the use of license numbers provided by Honeywell. Units will not support key features such as, but not limited to, the ability to decode PDF, 2D or OCR fonts without the proper licenses. Desired licenses can be specified at the time of sale or call a customer service representative for more information. Standard models ship with the ability to read all 1D, PDF and 2D bar codes. OCR fonts are disabled by default and must be specifically requested at an additional cost.
Scanner configuration bar codes require the manual activation mode.
2D matrix bar code types are not enabled by default in the manual activation mode. Refer to the Area-Imaging Supplemental Configuration Guide (see page 2) for additional information on enabling code types.
14