The text of a manual · part 5 of 14
Dolphin 60s with Windows Embedded Handheld 6.5 User's Guide: Customer Support, pages 39 to 48
Pages 39 to 48 of 136, from Dolphin 60s with Windows Embedded Handheld 6.5 User's Guide
The original document is the PDF (6.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Honeywell 60s
Page 39
For additional information on Advanced Power Settings, see page 6-20. For additional information on the Battery Log Configuration, see page 6-12.
System Resets See Resetting the Terminal on page 1-13.
Hardware Maintenance When needed, clean the image engine window and the touch screen with a clean, non-abrasive, lint-free cloth. The terminal can be cleaned with a damp cloth. Important - All battery and connector doors must be present, undamaged, and properly closed on the terminal to maintain an IP54 rating.
Installing a SIM Card and/or Memory Card SIM Card Short for Subscriber Information Module, a SIM card stores the subscriber's personal information, GSM/GPRS radio settings, security keys, contacts, etc. SIM cards can be installed in compatible mobile devices, enabling you to switch devices without losing personal and setup information. Before installing the SIM card, the service provider must activate the SIM card. Note: If no SIM card is installed, you can still make emergency phone calls (e.g., 9-1-1).
Installation 1.
Suspend the terminal. Press and release the Power key for approximately 4-5 seconds.
2.
Unlock and remove the battery door, then remove the battery.
3.
Slide the SIM Card latch toward the bottom of the terminal to unlock. SIM Card Latch
2 - 15
Page 40
4.
Lift the SIM card latch.
5.
Slide the SIM (contacts facing down) into the socket, then close the SIM card latch. Chamfered Corner of SIM Card
6.
Lock the SIM card latch by sliding the latch toward the top of the terminal.
7.
Install the battery, then attach and lock the battery door The terminal begins booting as soon as power is applied.
Memory Card You can expand the terminal’s memory capacity by installing a microSD or microSDHC memory card. Honeywell recommends the use of Single Level Cell (SLC) industrial grade microSD or microSDHC memory cards with Dolphin terminals for maximum performance and durability. Contact a Honeywell sales representative for additional information on qualified memory card options. Note: Format the memory card before initial use.
Installation 1.
Suspend the terminal. Press and release the Power key
2.
Unlock and remove the battery door, then remove the battery.
2 - 16 for approximately 4-5 seconds.
Page 41
3.
Slide the SIM Card latch toward the bottom of the terminal to unlock, then lift the SIM card latch. If a SIM card is installed, remove the SIM card to reveal the memory card latch. SIM Card Latch
4.
Slide the memory card latch to the left to unlock, then lift the memory card latch.
5.
Insert a MicroSD or MicroSDHC card into the socket aligning the corner on the card with the corner of the socket.
6.
Close the memory card latch, then lock by sliding the latch right. If you want to install a SIM card, insert the card into the SIM card socket (see SIM Card).
2 - 17
Page 42
7.
Close the SIM card latch, then lock the SIM card latch by sliding the latch toward the top of the terminal.
8.
Install the battery, then attach and lock the battery door The terminal begins booting as soon as power is applied.
2 - 18
Page 43
3 Using the Scan Image Engine
Overview The Dolphin 60s terminal houses a compact image engine that instantly reads popular 1D and 2D bar codes and supports omni-directional aiming and decoding for greater flexibility in real-world settings. The image engine can also capture black and white digital images, such as signatures and pictures of damaged inventory. With the latest CMOS-based technology, the engine works like a digital camera and enables black and white digital image capture, signature capture, and reading of OCR characters.
Image Engine Specifications Field of View Horizontal Field Angle (°) 21.9+/-0.5 degree Vertical Field Angle (°) 15.9+/-0.5 degree
Depth of Field The depth of field measurements used the following parameters: • Distances are measured from the front of the engine. • +23°C (+73°F), 0 lux • Photographic quality codes Symbology
Distance (in/cm) Near
Distance (in/cm) Far
Delta (in/cm)
3 mil C39/128
-
-
-
5 mil C39/128
2.25 (5.7)
4.35 (11.049)
2.1 (5.3)
7.5 mil C39/128
1.25 (3.2)
6.87 (17.4)
5.62 (14.3)
10 mil C39/128
0.67 (1.7)
9.93 (25.2)
9.26 (23.5)
15 mil C39/128
1.01 (2.6)
15.16 (38.5)
14.15 (35.94)
20 mil C39/128
1.80 (4.57)
18.56 (47.14)
16.76 (42.57)
100% 13 mil UPC
1.57 (3.9)
12.18 (30.9)
10.61 (26.9)
5 mil PDF417
-
-
-
6.7 mil PDF417
1.53 (3.8)
4.63 (11.7)
3.1 (7.8)
10 mil PDF417
1.38 (3.5)
7.34 (18.6)
5.96 (15.1)
5 mil microPDF
-
-
-
5 mil DataMatrix
-
-
-
10 mil DataMatrix
1.52 (3.8)
4.87 (12.3)
3.35 (8.5)
3-1
Page 44
20 mil DataMatrix
1.07 (2.7)
9.66 (24.5)
8.59 (21.8)
10 mil QR
1.50 (3.8)
5.13 (13.0)
3.63 (9.2)
20 mil QR
2.48 (6.3)
9.66 (24.5)
7.18 (18.2)
32 mil Maxicode
1.56 (3.9)
13.19 (33.5)
11.63 (29.5)
Supported Bar Code Symbologies Symbology Type
Symbology Name
1D Symbologies
Codabar Code 3 of 9 Code 11 Code 32 Pharmaceutical (PARAF) Code 93 Code 128 EAN with Add-On EAN with Extended Coupon Code EAN-8 EAN-13 GS1-128 GS1 Databar Interleaved 2 or 5
ISBT 128 Matrix 2 of 5 MSI Plessey Straight 2 of 5 IATA Straight 2 of 5 Industrial Telepen Trioptic Code UPC with Add On UPC-A UPC-E
2D Symbologies
Aztec Codablock A Codablock F Data Matrix
GS1 Databar MaxiCode Micro PDF PDF417 QR Code
Composite Codes
UPC/EAN UCC/EAN GS1 Databar
OCR
MICR E 13-B OCR-A OCR-B
Postal Codes
Postnet and most international 4-state codes Australian Post British Post
3-2
Canadian Post China Post
Page 45
Decoding The terminal supports two types of image decoding for use in various bar code reading and imaging applications: full-area imaging and Advanced Linear Decoding (ALD). Full-Area Imaging Full-area imaging provides omni-directional reading of linear and non-linear 1D and 2D bar codes, OCR, signature capture, and picture taking. When reading all bar code types using full-area imaging, a positive read can be obtained from many positions; see The Aiming Beam on page 3-3 To achieve the best read, the aiming beam should be centered horizontally across the bar code. ALD ALD provides fast reading of linear and stacked linear bar codes. To achieve a positive read when reading linear 1D and PDF417 bar codes, the aiming beam should be centered horizontally across the bar code. When ALD is enabled, the reader does not read matrix or postal codes.
Using the Scan Demo to Decode a Bar Code The aiming beam should be oriented in line with the bar code to achieve optimal decoding. 1.
Touch
> Demos
> Scan Demo
.
2.
Point the Dolphin terminal at the bar code. Press and hold the Scan button. Note: The right side button also triggers the scan/imager.
.
3.
Center the aiming beam over the bar code; see The Aiming Beam on page 3-3 Note: By default, the LED illumination and aiming beam options are enabled. For optimum performance, avoid reflections by scanning the bar code at a slight angle.
4.
When the bar code is successfully decoded, the terminal beeps and the bar code information appears on the touch screen.
The Aiming Beam The aiming beam is smaller when the terminal is held closer to the code and larger when it is farther from the code. Symbologies with smaller bars or elements (mil size) should be read closer to the unit whereas symbologies with larger bars or elements (mil size) should be read farther from the unit.
3-3
Page 46
Linear Bar Code
2D Matrix Symbol
Capturing Images Using the Imaging Demo The image-capture process is an intuitive, split-second operation for experienced users. By following the basic guidelines, new users can easily develop their own technique and, with practice, quickly learn to adapt it to different application environments. Image Preview When the imaging process is initiated, the touch screen displays a preview of the object. This is a live video image of what the imager is currently viewing. The live video image has a slightly degraded appearance compared to the captured image. This is normal. Scan Key On all Dolphin 60s terminals, the Scan button captures images. File Formats File formats supported for image storage include Bitmap (BMP), JPEG (JPG) and Portable Network Graphics (PNG). The default file format for images is a gray scale JPG. Compression Digital images have a maximum image size of 640 x 480 pixels and may have up to a 256 (8 bit) gray scale image definition. The image quality and related file size are determined by the data compression method used by the software application used to take images. The average size of the image file is approximately 4–8K. However, the size of the image depends on the content of the image - the more complex the content, the larger the file size.
Taking an Image The following steps are basic guidelines for taking images:
3-4
Page 47
1.
Touch
> Demos > Imaging Demo
.
2.
Point the Dolphin terminal at the object. To preview the image, press and hold the Scan button. Note: The general notification LED above the touch screen illuminates red while the Scan button is pressed.
3.
Adjust the terminal’s position until the object appears on the touch screen the way you want it to appear in the image.
4.
Release the Scan button to capture the image.
5.
Touch File on the Tile bar, then select Save or Save As. Note: Unless otherwise specified, the image is saved to the \My Device\My Documents folder.
Uploading Images Image files can be uploaded to a host workstation using Microsoft ActiveSync or Windows Mobile Device Center and a Dolphin communication peripheral. For additional information see Connecting and Synchronizing the Terminal and Workstation on page 7-9.
3-5
Page 48
3-6