Page 89

Tasks The Tasks screen enables you to initially configure, and then manage network settings when using a modem. Select an item in this list and then complete the setup screens that follow with the appropriate information for your network.

My ISP The links under the My ISP heading enable you to add and manage modem connections to an Internet Service Provider (ISP). To complete the setup screens, obtain the following information from your ISP: • • • •

ISP dial-up access telephone number User name Password TCP/IP settings

My Work Network The links under My Work Network enable you to establish the following connection types: • Modem • Virtual Private Network (VPN) • Proxy server connection Note: If you are connected to your ISP or private network during synchronization, the terminal should download the proper proxy settings during synchronization with the workstation. If these settings are not on your workstation or need to be changed, ask your ISP or network administrator for the proxy sever name, server type, port, type of Socks protocol used, and your user name and password.

To complete the setup screens, obtain the network parameters from your system administrator. 7-3

Page 90

Modify an Existing Connection The Manage existing connections link appears on the Connections screen under the My ISP heading after at least one network connection has been established. Touch Manage Existing Connections, then follow the setup screens to modify an existing connection.

Advanced The Advanced screen enables you to select the default network, dialing rules, and IP address exceptions for modem connections.

Note: You should not need to change Advanced settings because most ISPs now use DHCP addresses.

7-4

Page 91

Dolphin Wireless Manager The Dolphin Wireless Manager provides a centralized interface that enables and disables all the onboard radios. Each radio has its own configuration program. The Dolphin Wireless Manager also provides shortcuts to the configuration utilities for each radio. To open the Dolphin Wireless Manager do one of the following: 1.

Touch once on the Title bar to access the Horizontal Scroll bar, then touch

2.

Select, Dolphin Wireless Manager.

.

OR 1.

Touch

> Settings

> Connections

> Dolphin Wireless Manager

.

Dolphin Wireless Manager Window

The state of the radio is shown in the upper right corner of the radio box.

If applicable, information about the radio displays when the radio is activated.

7-5

Page 92

Enabling the Radios 1.

Open the Dolphin Wireless Manager (see page 7-5).

2.

Touch anywhere inside the rectangle of the radio you want to enable.

3.

The radio begins activating.

4.

When the radio is activated (i.e., transmitting a signal), the Off button changes to ON.

Note: If applicable, information about the radio appears in the rectangle.

7-6

Page 93

Accessing Radio Configuration Utilities Each radio has its own configuration utility that you can access by touching Menu on the tile bar.

Radio Type 802.11b/g/n

Menu Option Touch WLAN Settings and the Honeywell WLAN Security Supplicant opens. The Honeywell WLAN Security Supplicant User’s Guide is available for download from at www.honeywellaidc.com.

Bluetooth

Touch Bluetooth Settings and the Bluetooth Settings screen opens. For details, see Working with the Bluetooth Radio on page 9-1.

GSM/GPRS/EDGE

Touch Phone Settings and the Phone opens. For details, see Working with Wireless Wide Area Networking (WWAN) on page 8-1.

7-7

Page 94

USB to PC Enable advanced network functionality under the USB to PC connection settings if you are having trouble connecting and synchronizing your terminal with a workstation PC using a wired USB connection and ActiveSync or Windows Device Mobile Center. The advanced network functionality can also be enable to improve transfer speeds when synchronizing large groups of data or copying large files between the terminal and workstation. See Connecting and Synchronizing the Terminal and Workstation on page 7-9. 1.

Touch

> Settings

> Connections

> USB to PC

2.

Check the box next to “Enable advanced network functionality”.

3.

Touch OK, then attempt to sync the terminal and workstation PC.

.

Network Cards The Network Adapters screen provides access to set and configure the type of Network Adapter used by the Network card in the terminal. You can modify the adapter settings (e.g., Name Servers or IP address) by touching on the adapter type or highlighting the adapter and touching Edit at the bottom of the screen. Touch > Settings Adapters screen.

7-8

> Connections

> Network Cards to access the Network

Page 95

Connecting and Synchronizing the Terminal and Workstation To synchronize data between the terminal and the workstation, ActiveSync (version 4.5 or higher) or Windows Mobile Device Center (WMDC) must be installed and configured for the appropriate communication type on the host workstation (Windows-based PC) and the Dolphin terminal. Dolphin terminals ship with ActiveSync already installed. Therefore, if ActiveSync or WMDC is already installed on the host workstation, you just need to connect the Dolphin terminal to the host workstation (via Dolphin peripheral) to initiate communication. If ActiveSync (4.5 or higher) or WMDC is not installed on the host workstation, you can download and install the most current version of the software from the Microsoft Web site (http://go.microsoft.com/fwlink/?LinkId=147001). Note: ActiveSync on your Dolphin terminal works with WMDC on host workstations running Windows Vista or Windows 7 and with ActiveSync on host workstations running Windows XP. For detailed information on ActiveSync and WMDC visit the Microsoft Windows Phone Web site.

!

When communicating via ActiveSync or WMDC, your terminal is designed to be connected to the host workstation with a communication peripheral sold/manufactured by Honeywell, such as the charge/ communication cable. Use of any peripheral not sold/manufactured by Honeywell may cause damage not covered by the warranty.

Capabilities • Back up and restore your device data. • Copy (rather than synchronize) files between your device and workstation. • Control when synchronization occurs by selecting a synchronization mode. For example, you can synchronize continually while connected to your workstation or only when you choose the synchronize command. • Select which information types are synchronized, controlling how much data is synchronized. For example, you can choose how many weeks of past appointments you want synchronized.

Communication Types The Dolphin 60s terminal supports Hi-Speed USB communication (USB 2.0) via ActiveSync through the The I/O Connector (see page 2-10) on the bottom of the terminal and the microUSB port (see page 2-7) on the right side panel of the terminal. The maximum data transfer rate is 480 Mbps. A USB cable and/or a Honeywell hardware peripheral (e.g., HomeBase) allow the terminal to communicate with a workstation or to be networked through a USB hub. The Dolphin terminal defaults to USB communication out of the box.

Hardware Requirements for Setup • HomeBase, power supply (shipped with HomeBase) and a USB cable if one is not supplied with your Dolphin communication peripheral OR • The USB charge/communication cable (USB-CABLE-1) provided with your Dolphin terminal.

Software Requirements for Communication • ActiveSync (v4.5 or higher) or Windows Mobile Device Center installed and configured on the host workstation (PC), see Setting Up the Host Workstation on page 7-10. Note: ActiveSync or Windows Mobile Device Center must be setup on your workstation before you initiate synchronization from the terminal for the first time. 7-9

Page 96

• Windows 98 Second Edition, Windows Me, Windows 2000, Windows NT (4.0 SP6 or higher), Windows XP, Windows Vista, and Windows 7 operating systems.

Setting Up the Host Workstation To synchronize data between the terminal and the workstation, ActiveSync (v4.5 or higher) or Windows Mobile Device Center must be configured for same communication type on both the host workstation and the Dolphin terminal.

ActiveSync Verify that ActiveSync is configured to use the appropriate communication type. 1.

In the ActiveSync window on your workstation, select File > Connection Settings.

2.

Check the box next to “Allow USB connections”.

Connecting the Dolphin Terminal to the Host Workstation After setting up both the workstation and the terminal: 1.

Connect the Dolphin terminal to the workstation using a Dolphin communication peripheral.

2.

ActiveSync or Windows Mobile Device Center should open and connect automatically to the Dolphin terminal.

Synchronizing with the Host Workstation After setup, synchronization begins automatically whenever the terminal’s mechanical connector connects to a Dolphin peripheral that is connected to a host workstation with ActiveSync or Windows Mobile Device Center installed. For additional information visit the Microsoft Phone Web site (http://go.microsoft.com/fwlink/?LinkId=147001). Note: if you are having trouble connecting and synchronizing your terminal with a workstation PC using a wired USB connection and ActiveSync or Windows Device Mobile Center, try enabling the advanced network functionality setting from the USB to PC connections screen.

Exploring the Terminal from the Workstation ActiveSync 1.

Open the main ActiveSync window (on the desktop).

2.

Click Explore. This opens the Mobile Device folder for the terminal in Windows Explorer.

3.

The Dolphin terminal is now treated as a mass storage device, and transferring files is as simple as dragging and dropping or copying and pasting.

Windows Mobile Device Center 1.

Open Windows Mobile Device Center (on the desktop).

2.

Click File Management. This opens the Mobile Device folder for the terminal.

3.

The Dolphin terminal is now treated as a mass storage device, and transferring files is as simple as dragging and dropping or copying and pasting.

7 - 10

Page 97

Installing Additional Software Dolphin terminals ship with the operating system, radio drivers, and custom Honeywell software already installed. These are the default programs that install when your terminal first boots up. You can install additional software programs to the terminal provided that the following parameters are met: • The software program was created for a Windows Embedded Handheld 6.5 device. • The terminal has enough memory to store and run the program. • The program has an EXE, CAB, or DLL extension. When selecting programs, verify that the program and version of the program are designed for the Windows Embedded Handheld 6.5 and the terminal’s processor. You can verify your processor by touching > Settings > System > About. Make a note of the information in the Processor field on the Version screen. To install additional software, you can use the communication options described in this chapter. • Adding Programs Using ActiveSync or Windows Mobile Device Center, see page 7-11. • Adding Programs Using the Internet, see page 7-12.

Adding Programs Using ActiveSync or Windows Mobile Device Center Generally, software for Windows Embedded Handheld devices must be installed to the host workstation first, then transferred to the Dolphin terminal. Note: An active Microsoft ActiveSync or Windows Mobile Device Center connection between a host workstation and the Dolphin terminal is required to add programs. For additional information, see Connecting and Synchronizing the Terminal and Workstation on page 7-9.

1.

Download the program to the workstation from either the Internet or the install CD. You may see a single *.exe or setup.exe file, a *.cab file, or a *.dll file. Note: There may be several versions of files for different device types and processors. Select the file that matches the terminal’s processor.

2.

Read any installation instructions, Read Me files, or documentation that comes with the program. Many programs provide special installation instructions.

3.

Connect the terminal to the workstation via a Dolphin communication peripheral.

If the File is an Installer (*.exe or *.setup.exe) An installer program is one that installs on the workstation and the terminal simultaneously; one process installs to both devices. 1.

On the workstation, double-click the *.exe or setup.exe file. The installation wizard begins.

2.

Follow the directions on the workstation screen. The installation process includes transferring the software to the Dolphin terminal.

If the File is Not an Installer Some programs cannot be installed on PCs because they are designed exclusively for Windows Embedded Handheld devices. In these cases, the appropriate files must be stored on the host workstation and transferred to the terminal via ActiveSync Explore or Windows Device Mobile File Management. Note: You know that the program is not an installer because an error message stating that the program is valid but designed for a different type of computer appears when you try to install the program on the workstation.

7 - 11

Page 98

1.

If you cannot find any installation instructions for the program in the Read Me file or documentation provided with the software, do one of the following: a. Open ActiveSync and click Explore, or b. Open Windows Mobile Device Center and click File Management

2.

On the workstation, navigate to the folder containing the program file(s).

3.

Copy and paste the file(s) into the Program Files folder on the Dolphin terminal. Note: If you want the program to be part of the Autoinstall that occurs after a factory reset or software upgrade, paste the program file(s) in both the \IPSM\Honeywell\Autoinstall folder and the \Honeywell\Autoinstall.

4.

On the terminal from the Start screen, touch File Explorer, navigate to the folder where the program is located.

5.

Touch on the program file to start the installation. Note: If you copied the file to the \Honeywell\Autoinstall folder, you can perform a Soft Reset to install the program. For more information, see Hardware Maintenance on page 2-15.

Connecting the Terminal to a Wireless Network You connect the terminal to a wireless network through the on-board radio (802.11b/g/n, Bluetooth, and/ or GSM). Each radio has its own configuration utility and requires specific information about the wireless network to connect. Successful connection depends on your network infrastructure about which you will need specific information from your network administrator. WLAN (802.11b/g/n) The Dolphin 60s has a 2.4 GHz 802.11b/g/n WLAN (Wireless Local Area Network) radio. The radio is interoperable with other 802.11b/g/n, Wi-Fi compliant products including access points (APs), workstations via PC card adapters, and other wireless portable devices. The next step is to configure the connection parameters of the radio to connect to a wireless network. WLAN Radio The WLAN radio is configured in the Honeywell WLAN Security Supplicant, which you access by touching the WLAN SWC icon on the Start menu. For complete configuration instructions, download the Honeywell Secure Wireless Client (SWC) User’s Guide from www.honeywellaidc.com. A link to this guide appears on the Dolphin 60s product page.

Adding Programs Using the Internet When you have established a network connection, you can access the Internet and download additional software programs. Note: When selecting programs, verify that the program and version of the program are designed for Windows Embedded Handheld and the terminal’s processor. You can verify your processor by touching > Settings > System > About > Version. Make a note of the information in the Processor field.

1.

Open Internet Explorer and navigate to the program’s location. You may see a single *.exe or setup.exe file, or several versions of files for different device types and processors.

2.

Select the program version that matches your Dolphin terminal and processor.