Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 11

Dolphin 6000 with Windows Mobile 6.5 User's Guide, pages 11 to 20

Pages 11 to 20 of 104

The original document is the PDF (7.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Honeywell 6000

Page 11

RF Exposure Information (SAR) This mobile phone meets the government's requirements for exposure to radio waves. This phone is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission of the U.S. Government. The exposure standard for wireless mobile phones employs a unit of measurement known as the Specific Absorption Rate, or SAR. The SAR limit set by the FCC is 1.6W/kg and for Europe is 2W/Kg. Tests for SAR are conducted using standard operating positions accepted by the FCC with the phone transmitting at its highest certified power level in all tested frequency bands. Although the SAR is determined at the highest certified power level, the actual SAR level of the phone while operating can be well below the maximum value. This is because the phone is designed to operate at multiple power levels so as to use only the poser required to reach the network. In general, the closer you are to a wireless base station antenna, the lower the power output. The highest reported SAR values for this FCC ID are Part 22 Head 0.43 W/kg, Body-worn 0.603 W/kg; Part 24 Head 0.49 W/kg, Body-worn 0.568 W/kg; and Part 15 Head 0.086 W/kg, Body-worn 0.061 W/kg. The highest reported CE SAR for this product is: 900 band: 0.468 W/kg, 1800 Band: 0.433W/kg and WLAN:0.046W/kg. While there may be differences between the SAR levels of various phones and at various positions, they all meet the government requirement. The FCC has granted an Equipment Authorization for this model phone with all reported SAR levels evaluated as in compliance with the FCC RF exposure guidelines. SAR information on this model phone is on file with the FCC and can be found under the Display Grant section of www.fcc.gov/oet/ea/fccid after searching on FCC ID: HD56000. For body worn operation, this phone has been tested and meets the FCC RF exposure guidelines for use with an accessory that contains no metal and the positions the handset a minimum of 1.5 cm from the body. Use of other accessories may not ensure compliance with FCC RF exposure guidelines. If you do no t use a body-worn accessory and are not holding the phone at the ear, position the handset a minimum of 1.5 cm from your body when the phone is switched on.

For European Community Users Honeywell complies with Directive 2002/96/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 27 January 2003 on waste electrical and electronic equipment (WEEE), European REACH Regulation 1907/2006 of 1 June, 2007, and Restriction of Hazardous Substances Directive (RoHS)2002/95/EC of 1 July 2006.

Waste Electrical and Electronic Equipment Information This product has required the extraction and use of natural resources for its production. It may contain hazardous substances that could impact health and the environment, if not properly disposed. In order to avoid the dissemination of those substances in our environment and to diminish the pressure on the natural resources, we encourage you to use the appropriate take-back systems for product disposal. Those systems will reuse or recycle most of the materials of the product you are disposing in a sound way. The crossed out wheeled bin symbol informs you that the product should not be disposed of along with municipal waste and invites you to use the appropriate separate take-back systems for product disposal. If you need more information on the collection, reuse, and recycling systems, please contact your local or regional waste administration. You may also contact your supplier for more information on the environmental performances of this product.

Pacemakers, Hearing Aids and Other Electrically Powered Devices Most manufacturers of medical devices adhere to the IEC 601-1-2 standard. This standard requires devices to operate properly in an EM Field with a strength of 3V/m over a frequency range of 26 to 1000MHz. The maximum allowable field strength emitted by the Dolphin terminal is 0.3V/m according to Subpart B of Part 1 of the FCC rules. Therefore, the RF from the Dolphin terminal has no effect on medical devices that meet the IEC specification.

Microwaves The radio in the Dolphin RF terminal operates on the same frequency band as a microwave oven. Therefore, if you use a microwave within range of the Dolphin RF terminal you may notice performance degradation in your wireless network. However, both your microwave and your wireless network will continue to function.

1-3

Page 12

China RoHS 有毒有害物质名称及含量的标识格式 部件名称 (Parts Name)

(Names and Content of Hazardous Substances or Elements)

有毒有害物质或元素

(Toxic and Hazardous Substances or Elements)

铅 (Pb)

汞 (Hg)

镉 (Cd)

六价铬 (Cr6+)

多溴联苯 (PBB)

多溴二苯醚 (PBDE)

IS4813 x o o o o o

印刷电路板 (PCB)

x o o o o o

外壳 (Housing)

o o o o o o

连线 (Cables)

x o o o o o

液晶显示器 (LCD)

x o o o o o

电池 (Battery)

o o o o o o

键盘 (Keypad)

o o o o o o o: 表示该有毒有害物质在该部件所有均质材料中的含量均在 SJ/T11363-2006 标准规定的限量要求以下 (Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in China’s SJ/T11363-2006.) x: 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ/T11363-2006 标准规定的限量要求 (Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials for this part is above the limit requirement in China’s SJ/T11363-2006.)

Operating Temperature The recommended operating temperature for the terminal is -10°C to 50°C (14°F to 122°F).

Approvals by Country

1-4

Country

EMC, Radio, & SAR

Safety

U.S.A.

FCC Part 15, Subpart B Class B FCC Part 15, Subpart C, 15.247 FCC Part 15, Subpart E FCC Part 22H FCC Part 24E FCC SAR OET 65 Supplement C FCC 20.19

UL60950-1

Canada

ICES-003 (Class B) RSS 102, RSS-132, RSS-133, RSS210

CSA C22.2 No. 60950-1-07

European Community/CE

EN300328, EN301893, EN55022, EN55024, EN301489-1, EN301489-7/ 24, EN301489-17, EN300328, 3GPPTS 51.010-1, EN301511, EN301908, EN50360, EN50361, EN50371, EN50392, IEC6220-1, IEC6220-2, EN62311, EN300440

EN/IEC60950-1 EN/IEC60825-1

China

SRRC, MII

CCC

Brazil

Anatel

Mexico

COFETEL

Australia/New Zealand

A Tick (GSM), CTick (WLAN, BT)

NOM-019-SCFI-1998

Page 13

2 Getting Started Out of the Box Verify that the carton contains the following items: • Dolphin 6000 mobile terminal • Battery pack (3.7V Li-ion) • Quick Start Guide Note: If you ordered accessories for your terminal, verify that they are included with the order. Be sure to keep the original packaging in case you need to return the terminal for service. For details, see Customer Support on page 13-1.

Installing Battery Pack

!

Ensure all components are dry prior to placing the battery in the terminal. Mating wet components may cause damage not covered by the warranty.

The Dolphin 6000 device is shipped with the battery packaged separately from the terminal. Perform the following to install the battery: 1. Slide the latch to unlock the battery door. 2. Open the battery door. 3. Install the battery into the battery well.

4. Install the battery door.

Note: Install the battery door before powering on the terminal.

!

We recommend use of Honeywell peripherals, power cables, and power adapters. Use of any non-Honeywell peripherals, cables, or power adapters may cause damage not covered by the warranty.

Removing Battery Pack Perform the following to remove the battery: 1. Slide the latch to unlock the battery door. 2. Open the battery door.

2-1

Page 14

3. Remove the battery by lifting the tab.

Note: Gentle force is required to lift and remove the battery from the battery bay.

Charging the Batteries Power for the Dolphin 6000 terminal comes from the battery pack, which is accessed from the back panel.

Before Initial Use The terminals are shipped with the battery discharged of all power. The initial charging time for the battery pack is 4 hours. Insert the terminal into the HomeBase or connect to the Communication Cable to charge the battery.

!

We recommend use of Honeywell peripherals, power cables, and power adapters. Use of any non-Honeywell peripherals, cables, or power adapters may cause damage not covered by the warranty.

Charging Using the Communication Cable Note: The battery may be charged (via HomeBase, USB Communication cable) as long as the temperature is between 0-40°C (32-104° F). If the ambient temperature is less than 0° or greater than 40°C, the device runs off of battery power even if external power is applied. 1. Slide the terminal into the cup on the USB communication cable to mate with the I/O connector. 2. Plug the power adapter cable into the power connector on the USB Communication cable. 3. Plug the USB Communication cable into the appropriate port on the host terminal.

2-2

Page 15

4. Plug the power adapter into a standard wall outlet. The LED on front of the terminal flashes and illuminates red when the terminal begins the initializing boot process.

4

1

2

3

Booting the Terminal The terminal boots when power is applied and the PWR button is pressed for three seconds. Caution: Do not press any keys or interrupt the boot process. When the boot process is complete, the Home screen appears and the terminal is ready for use.

Note: The Home screen appears and the CAB files install. The Home screen appears a second time. Wait several seconds before using the terminal to make sure that the boot process is complete.

Using Touch Panel Display The touch panel display is activated by using a stylus (included with the terminal) or your finger. To activate the display, open a file or select a menu, use the tip of the stylus to tap the touch panel display or gently press the touch panel with your finger.

2-3

Page 16

Home Screen After the terminal initializes the first time, the Home screen appears.

Navigation Bar The Navigation bar is located at the top of the screen. The active program and current time are shown.

Command Bar The Command bar is located at the bottom of the screen.

2-4

Page 17

Navigation Bar Icons Indicator

Meaning Synchronizing data

The terminal could not synchronize data with the workstation via ActiveSync.

New e-mail

New text message

New voicemail

New instant message

Vibrate on

Ringer off Speakerphone on

Voice call in progress

Calls are forwarded

Call on hold

Missed call

Data call in progress

Battery has a full charge. Battery has a high charge.

Battery has a medium charge.

2-5

Page 18

Indicator

Meaning Battery has a low charge. Battery has a very low charge and requires charging. The terminal is running on external power. If a battery pack is installed, battery is charging in the background. The terminal is not connected to external power. A battery is installed, but is defective; its charge level cannot be measured. No SIM card is installed

GPRS available

GPRS connecting

GPRS in use

EDGE available

EDGE connecting

EDGE in use

Radio is off

The radio is not connected to a network.

The radio is connected. The bars indicate signal strength.

No radio signal

The terminal is searching for a signal.

Wi-Fi is on, but terminal is not connected.

2-6

Page 19

Indicator

Meaning Wi-Fi data call

Pending alarm

Bluetooth

Set Time Zone, Time, and Date 1. On the Home screen, tap the time and date section.

The Clock & Alarms menu opens. 2. Select the Time tab to set the system clock.

3. Tap the Time Zone box to open a drop-down menu.

2-7

Page 20

4. Set the correct time zone from the drop-down menu. 5. Set the correct time and date in the remaining fields and tap OK to save the settings.

Pop-Up Menus Pop-up menus allow you to choose an action for a selected file. 1. Tap and hold the stylus on the action to open the pop-up menu. 2. When the menu appears, lift the stylus, and tap the action desired.

3. Tap outside of the pop-up menu to close it without performing an action.

Selecting Programs 1. Tap to access the Start Menu.

2. Open the desired program by tapping on the program icon. 3. Move an icon to the top of the Start Menu by tapping, then holding the stylus on the icon, while dragging the icon to the top of the Start Menu.

2-8