Page 71

DATA BACKUP

9.

Data Backup To save your data and settings before the device is switched off to the Partially Off or Complete Off status, carry out a SysBackup (see Ch. 9.2.1)!

9.1

Data Backups in General The memory of the skeye.pos mobile consists of two areas: • • up to 1 GB flash and up to 256 MB RAM.

In the RAM, Windows CE creates • • • • the RAM, the files, the databases and the registry

The RAM memory allows rapid access. It is battery buffered, which means that the contents of the RAM memory are deleted if the battery is deeply discharged. The flash memory stores all the data contained in the "FlashStorage" folder and its subdirectories. The flash memory retains its data even if the battery is discharged. For this reason, all important files and programs should be saved in the "FlashStorage" folder. You should therefore back up the data on your skeye.pos mobile as often as possible! We also recommend that you copy important data onto your desktop PC or other storage media such as CDs.

2.01 • 25.03.2010 71

Page 72

DATA BACKUP

9.2

SysBackup You can use the "SysBackup" program to • create, • play back and • delete a backup.

9.2.1

Creating a Backup You should copy all important data to the "\FlashDisk" folder or its subdirectories. To ensure that all system settings are not lost after the battery is discharged or the device is switched to "Complete Off", you must save everything. 1. Start the "SysBackup" program, either: choose Start ⇒ Run and enter "SysBackup" in the input line in the "Run" window or choose Start ⇒ Programs ⇒ System ⇒ SysBackup. The "SysBackup" window opens.

Fig. 56: The "SysBackup" window

2. In the "SysBackup" window, select the [create] button by tapping. The "Execute backup?" message appears.

72

2.01 • 25.03.2010

Page 73

DATA BACKUP

Fig. 57: The "SysBackup" window with the "Execute backup?" message

3. Confirm the "Execute backup?" message with [Yes]. The SysBackup is executed. On completion, the following message appears.

Fig. 58: The "SysBackup" window with the "Backup completed" message

4. Close the message with [OK]. 5. Close the "SysBackup" window.

If you change your system settings (e.g. recalibrating the touch screen), you must then perform a SysBackup. Otherwise these settings will be lost, for example, if the device is switched to "Complete Off".

2.01 • 25.03.2010 73

Page 74

DATA BACKUP

9.2.2

Restoring a Backup 1. Open the "SysBackup" program.

Fig. 59: The "SysBackup" program

2. In the "SysBackup" window, select the [restore] button by tapping. The "Execute restore?" message appears.

Fig. 60: The "SysBackup" program with the "Execute restore?" message

3. Confirm the "Execute restore?" message with [Yes]. The backup is imported. 4. Close the "SysBackup" window.

74

2.01 • 25.03.2010

Page 75

DATA BACKUP

9.2.3

Deleting a Backup 1. Open the "SysBackup" program.

Fig. 61: The "SysBackup" program

2. In the "SysBackup" window, select the [delete] button by tapping. The "Erase backup files?" message appears.

Fig. 62: The "SysBackup" program with the "Erase backup files?" message

3. Confirm the "Erase backup files?" message with [Yes]. The contents of the directory \FlashDisk\SYSBAK are deleted. 4. Close the "SysBackup" window.

2.01 • 25.03.2010 75

Page 76

COMMUNICATION/DATA EXCHANGE

10.

Communication/Data Exchange

10.1

Driver Installation for Data Synchronization Install on your PC the program for data synchronization of a PC with a mobile device. This program should be appropriate to your operational system. Microsoft ActiveSync ⇒ for Windows XP Windows Mobile Device Center (WMDC) ⇒ for Windows Vista Device Stage ⇒ for Windows 7 These programs are available for free via www.Microsoft.com/getstarted. With this program you can handle the following tasks: adding and removing programs on the skeye.pos station synchronization of files transfer and copying of files

10.2

Accessing the Internet with a Wireless LAN Card The WLAN card is integrated into the mobile terminal (optional extra) and cannot be replaced by the user. The CF slot in the battery compartment is not suitable for WLAN. 1. Open Internet Explorer. 2. Enter an Internet address in the address field. The WLAN connection depends on access point and local LAN settings. If you have any questions, contact your administrator.

10.3

Ethernet Settings The Ethernet connection only works when your device equipment supports this function.

This setting is not normally required as the internal Ethernet controller automatically switches on as soon as an external current supply is connected to the skeye.pos mobile. The internal controller can also be switched on or off using the "CFConfig" tool.

76

2.01 • 25.03.2010

Page 77

COMMUNICATION/DATA EXCHANGE

1. Double-tap the "CFConfig" symbol on the desktop. The "Interface Config" window opens.

Fig. 63: The "Interface Config" window

2. Activate the checkbox "Enable internal Ethernet controller (LAN)" in the "Interface Config" window. 3. Close the "Interface Config" window with [OK]. 4. Select Start ⇒ Settings ⇒ Network and Dial-up Connections. The "Network and Dial-up Connections" window appears.

Fig. 64: The "Network and Dial-up Connections" window

5. Double-tap the following symbol to configure the Ethernet connection. In the following, you can perform further settings (e.g. static IP addresses, DHCP, configure DNS server).

2.01 • 25.03.2010 77

Page 78

COMMUNICATION/DATA EXCHANGE

10.4

GSM Settings 1. Go to Start ⇒ Settings ⇒ Network and Dial-up Connections This opens the Network Connections window.

Fig. 65: Network Connections Window

2. Double click Make New Connection. This will open the „Make New Connection“ dialog box.

Fig. 66: Make New Connection dialog box

3. In this window, do the following: • Enter GSM as name. • Select Dial-up Connection • Select [Next >]

78

2.01 • 25.03.2010

Page 79

COMMUNICATION/DATA EXCHANGE

This will open the “Modem” dialog box.

Fig. 67: Modem Dialog Box

4. Configure the Modem • Under “Select a Modem: “ select COM1: GSM/GPRS • Select [Configure]. This opens the „Device Properties“ dialog box.

Fig. 68: Device Properties Dialog Box

5. In this window, do the following: • Do NOT check Manual Dial. • Set baud rate to 115200. • Select [OK]. This will open the "Make New Dial-up Connection" dialog box.

2.01 • 25.03.2010 79

Page 80

COMMUNICATION/DATA EXCHANGE

6. In the Modem window, tap [Next >].

This will open the „Make New Dial-up Connection“ dialog.

Fig. 69: Make New Dial-up Connection window using freenet

7. In the Make New Dial-up Connection dialog box, configure the GSM connection for your Internet Service Provider: • Enter your provider’s phone number, for instance 22243 for freenet or the shown string for Vodafone. • Select [Finish]. You can of course configure the connection to use a different ISP using the appropriate phone number, user name and password. 8. Double-tap on the GSM icon in the Network Connections window. This will open the „Dial-up Connection“ dialog box.

Fig. 70: Dial-up Connection window

9. In this window, do the following: (lower case only, no quotation marks)

80