Page 51
DESKTOP CRADLE
5.2
Placing and Removing the skeye.pos mobile from the Desktop Cradle The desktop cradle can be used as follows: • Charging and operating the skeye.pos mobile, • Connecting to external devices • Connecting to a PC via USB interface (ActiveSync). Make sure that you place the skeye.pos mobile on the desktop cradle with a battery fitted and locked in place. Otherwise, the skeye.pos mobile cannot be switched on!
LED Function Displays
Connection to the skeye.pos mobile
Desktop Cradle Clips
Desktop Cradle Connector
Attachment slots for the clips on the desktop cradle
Fig. 39: Placing the skeye.pos mobile on the desktop cradle
Placing the skeye.pos mobile 1. Check that the skeye.pos mobile contains a battery and that it is locked in place. If so, continue to step 2 If not, insert a battery and lock it in place (see Ch. 4.8, Page 26). 2. Position the skeye.pos mobile over the desktop cradle so that the plug-type connection for the desktop cradle and the two attachment slots for the clips are precisely aligned. 3. Push the skeye.pos mobile onto the desktop cradle. Applying pressure to the skeye.pos mobile locks it onto the desktop cradle and the green LED starts to glow.
2.01 • 25.03.2010 51
Page 52
DESKTOP CRADLE
Fig. 40: The skeye.pos mobile correctly positioned on the desktop cradle
Removing the skeye.pos mobile Before it can be removed from the desktop cradle, the skeye.pos mobile must be unlocked.
Fig. 41: Unlocking
Lever
1. Slide the lever to the right. The clips on the desktop cradle release the skeye.pos mobile. 2. Lift up the skeye.pos mobile.
52
2.01 • 25.03.2010
Page 53
DESKTOP CRADLE
5.3
LED Function Display of the Desktop Cradle Three light emitting diodes (LED) are provided to display the operating states.
5.4
Red LED
•
Indicates that the desktop cradle is ready for operation
Yellow LED
•
Indicates that the desktop cradle is transmitting data
Green LED
•
Indicates that the skeye.pos mobile is correctly positioned and connected
Connecting the Desktop Cradle to a Desktop PC
USB Cable
Power Supply HW 14396 incl. Cable
Fig. 42: Connecting the desktop cradle
1. Use the USB connections to link the desktop cradle to your desktop PC. 2. Connect the power supply to the desktop cradle. 3. Connect the power plug to the electrical outlet.
2.01 • 25.03.2010 53
Page 54
BATTERY CHARGER
6.
Battery Charger
6.1
Charging the Battery in the Battery Charger The battery charger allows you to charge the lithium-ion battery separately. The recess is moulded in such a way that the battery can only be inserted correctly (reverse polarity protection).
Fig. 43: Battery charger
Inserting the Battery
Removing the Battery
54
The battery is inserted into the battery charger for charging. Insert the battery in the battery charger in exactly the same way as in the skeye.pos mobile. Position the battery vertically in the area marked, with the rounded side facing downwards. Fold the battery down and press it into place. Charging the • • Battery
To charge a battery, insert into the powered battery charger. If the yellow LED lights up, the battery is correctly inserted in the battery charger and is charged.
End of the Charging Procedure
•
The green LED lights up to indicate that the battery is fully charged again.
Charging Time
• A completely discharged battery will take approximately 2.5 to 3 hours to recharge. If the battery is not fully discharged, the charging time is reduced accordingly.
Fold the battery upwards and lift it out of the battery charger.
2.01 • 25.03.2010
Page 55
BATTERY CHARGER
6.2
LED Function Display of the Battery Charger Three light emitting diodes (LED) are provided to display the operating states.
Yellow Green
Red
Fig. 44: Location of the LEDs
Red LED Continuously lit •
Indicates that the battery charger is ready for operation flashing
•
Indicates a malfunction
Yellow LED
•
Indicates: the battery is charging
Green LED
•
Indicates that charging was successfully completed
2.01 • 25.03.2010 55
Page 56
HANDLING THE BATTERIES (POWER MANAGEMENT)
7.
Handling the Batteries (Power Management)
7.1
Charging the Battery If the battery needs to be charged, the following symbol bar. You must then charge the battery.
appears in the menu
The battery is automatically charged if your skeye.pos mobile • is fitted on the desktop cradle (with the power supply connected) • is connected to the power supply You also have the option of charging the battery in the battery charger (see Ch. 0).
7.2
Battery Maintenance An unused battery must be recharged every three months. After this length of time, the battery is discharged to such an extent due to self-discharging that it can no longer be used to operate a skeye.pos mobile.
In terms of maintenance, bear the following points in mind: Good: • Daily use of the battery • Allowing the battery to discharge until the "Charge Battery" symbol appears in the menu bar (see Ch. 7). • Charging using the battery charger HW 16396 or the desktop cradle HW 50396 Bad: • Only occasionally using the battery • Exposure to heat (increases self-discharging) • Exposure to frost Very Bad: • Total discharging • Humidity; aggressive vapors that cause corrosion of the contacts • Storage at temperatures below -20°C • Storage at temperatures below 0°C
56
2.01 • 25.03.2010
Page 57
HANDLING THE BATTERIES (POWER MANAGEMENT)
7.3
Maintaining the Internal Floating Battery To conserve the floating battery when not in use, the skeye.pos mobile should always be stored with a charged battery fitted! Otherwise the power reserves in the floating battery will be consumed. Discharged floating batteries must be replaced by qualified service personnel. If the battery is unlocked, the internal floating battery supplies the RAM with voltage for 3 minutes. This ensures that the RAM is not deleted during this time and that it is possible to change the battery while the RAM is in use. After you switch on the skeye.pos mobile, you can continue working from the same point. The internal floating battery requires no maintenance. The skeye.pos mobile automatically charges the internal floating battery. If the skeye.pos mobile is not placed on a desktop cradle for an extended period, the internal floating battery is charged from the battery.
7.4
Disposing of Old Batteries Old batteries as well as device storage batteries must not be disposed of with your household waste. Consumers are obliged to return batteries to a suitable collection point (trade, municipality). Device batteries can be returned to Höft & Wessel after use at no cost as well. Old batteries may contain heavy metals or harmful substances that may cause damage to environment and to health. Batteries are reusable. They contain important raw materials like iron, zinc, manganese, and nickel. Höft & Wessel (address see chapter 11.3, page 93) guarantees that all batteries returned are fed to the recycling process.
2.01 • 25.03.2010 57
Page 58
HANDLING THE BATTERIES (POWER MANAGEMENT)
7.4.1
Storing the skeye.pos mobile with the Battery To conserve the floating battery when not in use, the skeye.pos mobile should always be stored with a charged battery fitted! Otherwise the power reserves in the floating battery will be consumed. Discharged floating batteries must be replaced by qualified service personnel.
If the battery is removed or empty, the contents of the SRAM disk are powered by the floating battery. This significantly reduces the service life of the floating battery. An empty floating battery can cause the skeye.pos mobile to malfunction. Discharged floating batteries must be replaced by qualified service personnel. The skeye.pos mobile can be stored in "Complete Off" mode with a charged battery for up to six months without maintenance. The device can be stored with a charged battery in "Suspend" mode for up to three weeks without maintenance. Depending on the battery status, the skeye.pos mobile then automatically switches to "Partially Off" or "Complete Off" mode. If these storage periods are exceeded, power is drawn from the floating battery. A charged battery must be used afterwards. Storage should always be at room temperature (approx. 20°C).
58
2.01 • 25.03.2010
Page 59
HANDLING THE BATTERIES (POWER MANAGEMENT)
7.4.2
Influencing the Battery Endurance To maximize the endurance of the battery, the display can automatically switch off through several levels. For this purpose, the skeye.pos mobile switches to the following states when left unused: Level 1: Level 2: Level 3:
The display is dimmed (Dim display) The display is switched off (Turn off display) The device switches to "Suspend Mode" (Auto suspend)
default: 15 s default: 1 min default: 2 min
The times at which the skeye.pos mobile switches from one status to the other can be changed using the "AutoOff" function in the Control Panel. 1. Choose Start ⇒ Settings ⇒ Control Panel ⇒
Fig. 45: The "Auto Off" window
2. Use the checkboxes and the controllers to adjust the settings as required and confirm the settings with [OK]. Note the following: The shorter you set the times, the longer the battery is available until the next charge.
2.01 • 25.03.2010 59
Page 60
ADDITIONAL FUNCTIONS AND SETTINGS
8.
Additional Functions and Settings
8.1
Scan of barcodes Call HWImagerTool to test the scanner function: Start ⇒ Programs ⇒ Utilities ⇒ HWImagerTool HWImagerTool executes in the background and can be identified by the SystTray symbol.
HWImagerTool can be used to scan into any text field (e.g. WordPad). Calmly and angularly hold the skeye.pos mobile in the direction of the barcode to be scanned. A peep indicates that the entry of the barcode has been successful. The distance should amount to about 10 cm. For more information please enquire for a separate HWImagerTool user guide. Programming interfaces for Imager are available.
8.2
Calling the Desktop at any Time To minimize or hide all open windows, tap the following symbol in the menu bar on the bottom right
60