Page 9

Installation and Startup

Introduction This guide is designed to help guide you through the installation of your Transaction Team 1500. It covers everything you’ll need to know - from minimum system requirements and package contents, to hardware and software installation procedures.

Minimum System Requirements The TT1500 is designed to quickly and easily connect to a wide variety of host systems. In fact, all that is really needed to connect this unit to a host is an available serial port. However, it is important to note that the level of functionality the TT1500 delivers is dependent on the software application you will be running. Because of this, your actual minimum system requirements will vary. The following minimum system requirements can be used as a general guideline: Minimum Hardware Requirements • An available serial port System Requirements for Development Software • IBM-compatible PC • MS-DOS®, Microsoft® Windows® 3.1, Microsoft® Windows® 95, Microsoft® Windows® 98, Microsoft® Windows® 2000, or Microsoft® Windows NT® • Available host computer register port (IBM-compatible PCs generally designate serial ports as COM1 through COM4. These are usually located on the back of the computer.)

Unpack and Check Contents Please check to ensure that your kit package included all of the standard items listed below: • Transaction Team 1500 • Durable non-electronic stylus • Startup Guide • TT1500 Software Suite CD • RS-232 Cable • Power Supply

1

Page 10

If you are missing any of the above items, please contact the supplier where you purchased your TT1500 Signature Capture Device. Optional Accessories • Tethered stylus with thumbscrew • Additional non-electronic stylus • Paper guide • Power adapter for PC keyboard/mouse port Cables • AC Power Adapter • RS-232 cable (HDB15-D89), cable length: 12, 20, 30 feet or • RS-232 pass-through Y cable (HDB15-Dual DB9), cable length: 12 feet

Hardware Installation Procedures Before you begin the installation process, you need to determine what type of cable you will be using (see page 2 for cable options). If you are installing an RS232 cable with an AC power cable, see page 3. If you are installing a power adapter cable, see page 4. If you are installing an RS-232 pass-through cable, see page 5.

2

Page 11

RS-232 Cable / AC Power Installation

2. Plug HDB15 connector into TT1500

4. Plug AC power supply into DB9

Host

3. Plug DB9 connector into host

1. Make sure the power switch is turned off on the computer where you will be installing the TT1500. 2. Plug the 15-pin connector (HDB15) of the serial cable into the back of the TT1500. 3. Plug the 9-pin1 connector (DB9) of the serial cable into an available serial port on your computer (usually COM port 1). 4. Plug the male connector of the AC power supply into the socket on the back of the 9-pin serial cable connector (DB9) which is plugged into the back of your computer. 5. Plug the base of the AC power supply into a standard 120 volt, 60 Hz, AC power outlet. Installation is now complete. You may now turn on your computer.

1. If your computer has a 25-pin serial port, you will need to obtain a 25-pin to 9-pin adapter from your local computer store or other source.

3

Page 12

Power Adapter Cable Installation

2. Plug HDB15 connector into TT1500 Host 5. Plug mouse into short connector 6. Plug into DB9

3. Plug DB9 connector into host

4. Plug lead into mouse port

1. Make sure the power switch is turned off on the computer where you will be installing the TT1500. 2. Plug the 15-pin connector (HDB15) of the serial cable into the back of the TT1500. 3. Plug the 9-pin1 connector (DB9) of the serial cable into an available serial port on your computer (usually COM port 1). 4. Plug the single lead coming from the PS/2 cable into the mouse port on the computer. 5. Plug the mouse into the shortest PS/2 connector on the two-lead side. 6. Plug the remaining long connector into the socket on the back of the DB9 connector, which is plugged into the host.

1. If your computer has a 25-pin serial port, you will need to obtain a 25-pin to 9-pin adapter from your local computer store or other source.

4

Page 13

RS-232 Pass-Through Installation

2. Plug HDB15 connector into TT1500

Host

4. Plug Aux DB9 connector into peripheral

5. Plug AC power supply into DB9

3. Plug one DB9 connector into host

1. Make sure the power switch is turned off on the computer where you will be installing the TT1500. 2. Plug the 15-pin connector (HDB15) of the serial cable into the back of the TT1500. 3. Plug one of the host DB9 connectors into your host computer. 4. Plug the Aux DB9 connector into your peripheral device. 5. Plug the male connector of the AC power supply cable into the socket on the back of the 9-pin serial cable connector (DB9) which is plugged into the back of your computer. 6. Plug the base of the AC power supply into a standard 120 volt, 60 Hz, AC power outlet.

5

Page 14

Software Installation Installing the TT1500 Software Suite The Transaction Team 1500 comes with a TT1500 Software Suite CD. This CD contains a 16 and 32-bit Software Development Kit (SDK) for use with the TT1500. The SDK consists of Tool Kit components and Software Utilities. The Tool Kit components provide various software tools to be used in conjunction with the appropriate software compiler or integrated development environment, which will enable you to develop your own software applications for use with the TT1500. The utilities software demonstrates the capabilities of the TT1500. The utilities were developed using the components of the Tool Kit. To install the 16 or 32-bit SDK, turn on your computer and insert the TT1500 Software Suite CD into the CD drive on your computer. Select and run the setup program using the following procedure: 1. Place CD in the disk drive. The setup program appears. 2. Select either 16 or 32-bit SDK installation and follow menu steps until completion is indicated.

or 1. With the CD in the disk drive, go to the Start menu and click on Run. 2. Select Browse and click on your CD drive. 3. Double click on Setup. 4. Click on OK. 5. Select either 16 or 32-bit SDK installation and follow menu steps until completion is indicated. The Transaction Team 1500 is now set up with the necessary software tools and utilities. You now should be able to develop your own applications using the Tool Kit or demonstrate the capabilities of the TT1500 using the Software Utilities. For the latest updates, visit the Hand Held Products website at www.handheld.com.

NOTE: The appropriate software compiler (Microsoft C/C++, Borland C/C++) or Integrated Development Environment (Visual Basic, Visual C++, etc.) is required for you to develop your own applications. This compiler is NOT provided in the TT1500 Software Suite.

Contents of the SDK Tool Kit The SDK Tool Kit components include the following libraries that can be used to develop your own applications in conjunction with your Microsoft C/C++ or Borland C/C++ compiler for use with the TT1500:

6

Page 15

• PADCOM - Handles all the protocol necessary to communicate to the connected unit. Implements an operating system dependent RS-232 communications protocol. PADCOM links a C/C++ application on the CPU to the Transaction Team hardware. DOS, WIN16 and WIN32 PADCOM libraries are supplied for Microsoft and Borland applications development. • SIGKIT - Aimed at post-processing signature data gathered from the unit using PadCom. SIGKIT handles signature storage and retrieval and allows a C/C++ application to utilize signatures. DOS, WIN16 and WIN32 SIGKIT libraries are supplied for Microsoft and Borland application development. The SDK Tool Kit include the following ActiveX OCX control to be used to develop your own applications in conjunction with an ActiveX compatible development environment (Visual Basic, Visual C++, etc.) for use with the TT1500: • SIGBOX - Applications use SIGBOX to link to the Transaction Terminal hardware. SIGBOX handles signature/Point-of-Sale data storage and retrieval. SIGBOX combines the functionality exposed in both the SIGKIT and PADCOM libraries. 16 and 32-bit OCX’s are supplied for application development. For further detailed information on the SDK Tool Kit components, refer to the respective user guides that are placed on you PC during installation.

Contents of the SDK Utilities The Software Utilities includes the following applications that can be used with the TT1500 to demonstrate its capabilities: • GETSIG for DOS and GETSIGW for Windows - GETSIG/GETSIGW can be used as a standalone program for capturing, saving, loading, displaying, and converting signatures. It can place signatures on the Windows clipboard. It works like a dialog box that can be called from other programs. For example, an MS Word macro can call GETSIG to display a dialog box that captures a signature and places it on the Windows clipboard, and then pastes it into a Word document. A shortcut can be created to capture or display signatures using GETSIG as a dialog box. • SIGTOOL (for Windows) - SIGTOOL works as a stand alone program. SIGTOOL can view and can capture signatures from the Transaction Team hardware. SIGTOOL can save, load, compress, and alter signatures. SIGTOOL can convert signatures to different formats and can copy signatures to the Windows clipboard • TESTER (for Windows) - Tester is used only for testing Transaction Team hardware (MSR, Signature Capture, Graphics, PINPad).

7

Page 16

The Software Utilities also include a TT1500 initialization/hardware setup program: • TTINIT - TTINIT works as a stand alone program for setting up the TT1500 hardware (pad calibration and LCD Clear Time). TTINIT can also be used to test the TT1500 hardware by displaying a signature captured from the pad.

Pad Calibration The Transaction Team 1500 has a LCD screen. Pad calibration allows the touch surface of the device to be calibrated with its LCD. To calibrate the TT1500 via the TTINIT program: 1. Run the TTINIT program. 2. Click on the Start Calibration button. A cross appears in the upper left corner of the LCD. 3. Touch the LCD’s surface at the center of the cross. Another cross appears in the lower right corner of the LCD. 4. Touch the LCD’s surface again at the center of this new cross. The device is now calibrated. 5. Click on OK to return to the main window of the TTINIT program.

LCD Clear Time You can set the LCD to automatically clear itself when a specified number of seconds elapses without any device activity. For example, if the clear time is set to 30, the device automatically clears itself when 30 seconds have elapsed since the last time it was touched. To configure the LCD Clear Time via the TTINIT program: 1. Run the TTINIT program. 2. In the main window of the TTINIT program, there is a LCD Clear Time frame. Position your cursor to the text box and enter the number of seconds for the clear time into the text box. 3. Verify by signing and seeing the LCD clear after the amount of seconds you have entered. 4. The device LCD clear time has now been set to your specified value. It retains this value even after powering off. To reset the LCD clear time, rerun the TTINIT program and repeat steps 1-3.

8