For the HHP SV 100

Page 22

TECHNICAL SPECIFICATIONS Physical • • • • • •

Package: 4.4” (112 mm) x 2.4” (61 mm) x 5.2” (132 mm) Indications: 5 LED’s – Power/Sync, Calibration, Read, 2 programmable LED’s 1 and 2 Comm Port: DB-9 male, RS 232C, programmable baud rate up to 115200 baud I/O-Power: DB-15 male, 5 programmable outputs, 2 sync inputs +5VDC @ 1 amp required Mounting: 2 sets of mounting holes on 2 different surfaces or a clamp for tightening to a 3/8” (9.5 mm) rod

Environmental • • • •

Operating Temperature: 40°F to 105°F ( 4°C to 41°C) Storage Temperature: -4°F to 140°F (-20°C to 60°C) Humidity: 10% to 90% non-condensing Ambient light: Not to exceed 0.5 mWatts/sq-mm 600 nm to 700 nm (this is calculated at about 2 percent of light level - estimate, not verified)

MTBF •

10,000 hours (est.) Dominated first by motor life, second by laser life.

Laser Scanner • • • • •

Scan rate: 400 scans/second (s/s), +/- 2 s/s Laser power: 3.0 mW, +/- 0.5mW Wavelength: 650 – 670 nm Beam shape: elliptical, RJS proprietary design for detection of print failure mechanisms. Class IIIa Laser Product; see labeling details in Caution Section of Preface

Scanning Performance •

SV Series Model Specifications*

Analyses/sec Scan Width Focus Distance X dim (min)

SV100 100 6” (152mm) 8” (203 mm) .0067” (.17mm)

SV100HD 100 4.5” (114mm) 6” (152mm) .005” (.127mm)

SV100C 100 10.5” (267mm) 15” (381mm) .013” (.33mm)

SV200-1 200 2.5” (63.5mm) 8” (203mm) .0067” (.17mm)

SV200-2 200 1.75” (44mm) 6” (152mm) .005” (.127mm)

* Contact RJS Technical Support for information on custom and other models •

All Models - 4 bar codes across max. (picket fence direction)

Scanner Options Scanners can incorporate options for special optics and/or be focused for special applications. Contact RJS Technical Support and describe your application for assistance. Below are two standard options available. High Density Focus: Analyze bar codes with 5 mil X dimension Rastering Scan line: Approximately .25 inch (6.4mm) vertical area scanned (in eight increments.) Note: a rastering scan beam is useful for analyzing an area of a code by using multiple scans. Typical applications are in static position scanning and in ladder mode travel direction scanning.

19

Page 23

Power • •

+5 Volts DC, +/- .25 Volt 1 amp maximum

Sync See the Sync Inputs Section for more details I/O connector pin 4 input: • ttl switching level threshold • Maximum input voltage swing: +/- 12 VDC • 100 K ohm internal pull-up resistor to 5 volts DC I/O connector pins 1 (+), 2 (-) isolated input: • Volts DC nominal input for sensing • 30 Volts DC maximum input • This input is ground isolated from 5 VDC power • Sync input recovery time: 12.5 milliseconds minimum

Outputs • • •

Open Drain FET (Field Effect Transistor) – no internal pull-up resistor External Pull-up Voltage: 0 - 30 Volts DC Sink current: 100 milliamps maximum

SYMBOLOGIES • • • • • • •

USS Code 128 USS Code 39 USS Code 93 USS Codabar USS Interleaved 2 of 5 UPC versions A and E (including 2 and 5 digit supplemental codes) EAN-13 and EAN-8 (including 2 and 5 digit supplemental codes)

OPERATION MODES The SV Series is very flexible, with many programmable features, but basic system operation can be broken down into three modes. Two modes include a sync signal and one mode operates without a sync signal. These modes are programmable via SV Command Language and RJS ScanVision software.

Sync Mode – Moving Bar Codes In this mode, a sync signal is used as an indicator to determine when an object or label containing a bar code(s) has entered or exited the laser beam. Bar codes are analyzed and ports activated, transmissions sent, etc. as the bar codes pass through the beam. The SV unit is programmed for the number of bar codes to expect during a sync period (see Sync Input Section), therefore the SV unit can detect missing or undetectable bar codes. A hardware input is the most common sync source for this mode. Note: When in this sync mode, the sync input is a background application. The SV Series will scan, analyze and report on bar codes as they pass through the beam in this mode, regardless if a sync signal is sensed. The presence of a sync signal allows the number of codes expected (programmed) during the sync period to be used for a No Read condition. The absence of a sync signal results in operation similar to the Free Scan Operation described later.

20

Page 24

Sync Mode – Stationary Bar Codes In this mode, a bar code(s) are placed in the beam and held in a known position. A sync input commands the SV Series to turn on the laser beam, perform a programmable number of scans, report the analyses and turn off the laser beam. A ~SA communication sync command is the most common sync source in this mode. A rastering laser option is often used to analyze bar code area. Note: The SV Series must be programmed for Picket Fence travel orientation in this mode.

No Sync – Free Scan Operation In this mode, a sync signal is not used and the SV unit scans and analyzes bar codes at random as they pass through the laser beam. As stated in the Sync Input section, this mode is not recommended because it cannot report on missing or undetectable bar codes that can be caused by printer or other system component failures. This mode is most acceptable when the SV Series is used as a bar code decoder only. It is recommended to use serial communications to a host in this mode in order for the host to determine missing codes. If this mode is used, the SV Series can still detect many print errors because of its partial decode analysis capability. This algorithm can detect a bar code start or stop character and two adjacent characters. This part of a code is usually present in most print failure situations. For maximum reliability for partial decode analysis, the bar code(s) being analyzed must be present in the laser beam for 10 scans (example: 100 milliseconds for SV units with 100 scans/analyses per second performance). To calculate bar code travel speed in this mode, see the Bar Code Travel Speed Considerations section. Calculate the maximum speed for the application per those instructions and then divide the speed by two for this application.

PARAMETERS ANALYZED For each bar code scanned and analyzed, the SV Series performs practically all the ANSI, traditional and laser based verification methods documented in industry specifications. All analysis parameters for these methods are reported via serial communications (see Serial Port Transmission Format section) and most of the parameters can be used in any combination to activate the five ports. The analysis parameters performed are listed below in the same order of the standard transmission format as applicable. Reference Decode (ANSI method parameter) Decodability (ANSI method parameter) Modulation (ANSI method parameter) Defects (ANSI method parameter) Edge Contrast (ANSI method parameter) Rmin/Rmax (ANSI method parameter) Symbol Contrast (ANSI method parameter) PCS (Traditional method parameter) Reflectance – Light (Traditional method parameter) Reflectance – Dark (Traditional method parameter) Ratio (Traditional method parameter) Average Bar Deviation (Traditional method parameter) Minimum Bar Deviation (Traditional method parameter) Maximum Bar Deviation (Traditional method parameter) Quiet Zone (Traditional method parameter) X Dimension (Traditional method parameter) Overall Symbol Grade (ANSI method parameter) Bar Code Direction (scanner decoder function)

21