Page 15

Symbology Identifier Table Identifiers 02 03 04 05 06 11 15 19 12 16 20 13 17 21 14 18 22

Symbology Category I 2 of 5 Code 128 Code 93 Code 3 of 9 Codabar UPC-A UPC-A w/add-on (2) UPC-A w/add-on (5) EAN-13 EAN-13 w/add-on (2) EAN-13 w/add-on (5) EAN-8 EAN-8 w/add-on (2) EAN-8 w/add-on (5) UPC-E UPC-E w/add-on (2) UPC-E w/add-on (5)

INSTALLATION AND SETUP Scanner positioning and proper system setup are extremely important for proper SV Series operation. Positioning is important in order to provide accurate analyses. The scan distance must be set accurately to achieve the proper beam focus in order to detect printer flaws and failures such as a worn ribbon (matrix printing), low toner (laser printing), voids (flexo printing), burned pixels (thermal printing), etc. The scan angle is important to accurately measure bar code and substrate reflectance values. Setup is important to ensure proper interface to print mechanisms, host computers, etc.

12

Page 16

Scanner Positioning Each SV Series has an attached label that indicates the type of scanner, focus distance and recommended scan angle. Use the scan distance and scan angle information to mount the scanner per Figure 2.

Figure 2 – Scanner Positioning

Notes: 1. Scan distance is measured from the protruding edge of the face of the scanner. 2. Scan angle is measured in degrees relative to vertical from the surface of the bar code. 3. The scanner can be mounted in any orientation, the figure is meant to show the beam angle relative to the bar code placement in the beam.

13

Page 17

Bar Code Travel Direction Bar codes can be scanned in a static location, or more commonly with on-line scanner/verifiers, they can be scanned while moving through the laser beam. Refer to Figure 3. It shows the two directions a bar code can travel through the laser beam. They are designated “picket fence” and “ladder” directions. Figure 3 – Scan Direction Picket Fence Travel Direction Laser Beam

Ladder Travel Direction

The SV unit must be programmed for the direction of travel of the codes being analyzed. If the codes are being scanned in a static condition, use picket fence travel direction.

Bar Code Travel Speed Considerations A bar code should be present in the beam for at least five scans for most reliable operation. The SV Series performs a minimum of 100 scans/analyses per second. At that rate, each analysis is accomplished in 10 milliseconds max. Therefore, a bar code must be in the beam for at least 50 milliseconds to be reliably analyzed. Some SV models have higher minimum scans/analysis, therefore a bar code must be in the beam for less amount of time for those models.

Picket Fence Direction In picket fence travel direction, a bar code is in the laser beam throughout the height of the shortest bar in the code. An easy way to estimate the fastest speed the code can travel through the beam is to divide the height of the shortest bar in the code by the maximum time required for the SV unit to take five scans of the code. Example: Calculate the maximum travel speed where the shortest bar height in a code is .5 inches and the SV model being used performs a minimum of 100 scans/analyses per second. Five scans requires 50 milliseconds (.05 seconds) to gather, so .5 inches (bar code height) divided by .05 seconds (time needed to gather 5 scans) = 10 inches/second. Therefore the maximum speed the code can travel through the beam is 10 inches per second. Vertical distance between bar codes is also a speed consideration in picket fence direction. The SV Series must have five continuous scans where no bar code is detected to reliably exit a bar code when operating in the standard operation mode set by Command ~HO1. Assuming 100 scans per second minimum, this means the vertical distance between the codes must take at least 50 milliseconds to pass through the laser beam. Calculate the maximum speed by measuring the shortest vertical space between bar codes on a label (or between labels.) Divide this distance by .050 (seconds). The result is the fastest speed the codes can move through the beam. If the application travel speed cannot be met due to a short vertical distance between codes, Command ~HO2 can be used to cause the SV to exit on a change in data rather than detecting no bar code. If using ~HO2, ensure the bar codes with short vertical gap are encoded with different data and only one code across is being analyzed in each scan. The slower of the two print speeds calculated above for bar height and gap height is the maximum recommended speed for picket fence travel.

14

Page 18

Picket Fence Bar Code Positioning Specifications: • Four codes across maximum • Horizontal gap between codes: .5 inch (13 mm) minimum • Maximum number of codes per sync period: 99

Ladder Direction In ladder direction, one bar code at a time is usually in the beam. The amount of time the code is in the beam is a function of the total width of the code (including quiet zone), the length of the beam area that is used for scanning and the speed the code is travelling. The distance the bar code is in the beam is calculated by subtracting the bar code width from the length of the beam programmed to scan the bar code. (See Setting Ladder Mode Scanning Length Section below.) Divide this difference by the amount of time the SV model requires to gather 5 scans to get the maximum speed. Example: a bar code with total width of 3 inches is to be analyzed in a beam length of 6 inches and the SV model being used performs a minimum of 100 scans/analyses per second. Maximum speed of travel is (6 –3)inches /.050 seconds = 60 inches per second in ladder direction.

Setting Ladder Mode Scanning Length Using ScanVision Software The distance and location in the laser beam where a bar code is scanned sometimes must be tuned (programmed) for a particular ladder mode application. In general, the wider the length, the faster the bar codes can travel. In some cases, a narrower scan length is required to mask an adjacent code so only one code at a time is scanned. Instructions for using ScanVision software to program the scanning length is provided in the Setup Procedure Section.

Calibration Calibration is required if any reflectance calculation (symbol contrast, Rmin, PCS, etc.) is used in the application. It is recommended to calibrate the unit in any case during initial setup to ensure the scanning distance and orientation is within device limits. A calibration symbol is supplied with each SV unit as a standard component. Store it in a clean location. The SV Series can be calibrated using either of the two following procedures: Procedure 1: 1. Remove all bar codes from the laser beam path. 2. Place the supplied calibration symbol in the laser beam in the same position (distance and angle) as the labels to be verified will be scanned. 3. Press and hold the RESET button on the SV unit until the Calibration LED begins to flash. 4. Release the RESET button immediately after the Calibration LED begins flashing. 5. If calibration is successful, the laser beam will go off and the Calibration LED will go off. Remove the calibration symbol from the beam path and Press the RESET button until the beam turns on. The SV unit is now ready to operate. 6. If calibration is unsuccessful, the Calibration LED will be either on steadily or flashing. In this case, repeat the calibration procedure. Procedure 2: 1. 2. 3.

4.

Place the supplied calibration symbol in the laser beam in the same position (distance and angle) as the labels to be verified will be scanned. Send “~SC” into the SV unit serial port. This will cause the Calibration LED to flash. If calibration is successful, the laser beam will go off and the Calibration LED will go off. Remove the calibration symbol from the beam path and then Press the RESET button until the beam turns on. The SV unit is now ready to operate. If calibration is unsuccessful, the Calibration LED will be either on steadily or flashing. In this case, repeat the calibration procedure.

15

Page 19

Once calibration is successful, re-calibration is not required unless the unit has been moved – either on its mounting stand or into a new location. It is advised to keep the laser beam exit window clean. Dirt, dust, fingerprints, etc. on the exit window can affect calibration.

Setup Procedure It is highly recommended that RJS ScanVision be used to set up SV Series units. This Windows based software is available free of charge from RJS. The alternative is to use SV Command Language through a host computer. See the SV Command Language Section for details. Installation of an SV scanner/verifier requires proper mounting position, port configuration(s) and LED configurations to ensure reliable and accurate operation. This section describes the procedures for using ScanVision to ensure proper SV setup and installation. Each SV unit has a label showing the specified mounting distance and target scan angle for its particular scanner. Follow the steps below to ensure the SV unit is properly mounted and programmed. 1. Mount the SV unit at the proper distance and angle. Use Figure 2 as a reference. 2. Connect power and communication cables to the SV unit. 3. Set the SV unit for picket fence bar code travel direction. 4. Place a sample bar code in the center of the intended laser beam path. For best results, this sample should match the type of bar code(s) and material that is to be analyzed in the final application. Knowing the X dimension (narrow element width) of the bar code(s) is a big plus as will be seen in Step 5. Note:SV Calibration symbols have a 10 mil X dimension unless otherwise indicated. 5. Take a Scan Profile with ScanVision. a. Ensure the bar code(s) is in the center of the scan path. b. Ensure the scan profile contains no distortion from light reflecting from objects in or near the light path. Examples of a good and bad reflectance profile are shown in Figures 4a and 4b respectively at the end of this section. One major aspect in a good profile is the low reflectance points (the bars) in the symbol are uniform all the way across the code. Optimum signal amplitude should be adjusted so the bar code element reflectances are between the 90% and 10% marks shown in yellow on the screen. Scanner angle has the most effect on the signal amplitude. c. Continue adjusting the SV unit’s placement until a good, centered scan profile is obtained. The scan angle may have to be altered slightly or a light shield may have to be installed in extreme cases to achieve a good reflectance profile. If adjustment of scan angle does not produce the correct signal amplitude or placement, adjust scanner gain and offset per the Adjusting Scanner Gain and Offset Section. 6. * Place ScanVision in Session Mode. a. Click on the Report an Analysis Speedbutton. b. Ensure that X in the lower panel of the Bar Code Analysis Screen matches the X dimension of the symbol within +/- .1 mil. c. Adjust distance of the SV unit from the bar code until the X dimension matches the desired value. (If X is analyzed as too large, move the scanner farther away; if X is too small, move the scanner closer.) 7. Repeat steps 5 and 6 until no more mounting adjustments are required. 8. Remove the symbol from the laser beam path. 9. Program the SV unit’s ports, LED’s, sync mode, etc. (if required). 10. Calibrate the SV unit if any reflectance parameters (such as symbol contrast) are programmed in this application to report to a host or activate any ports. Each SV unit is supplied with a calibration symbol. 11. The SV scanner/verifier is now ready to operate for picket fence bar code travel direction. If Ladder Mode is being used and the desired scanning length for ladder bar code travel direction is programmed, place the unit in ladder mode. The unit is now ready to operate. If ladder mode scanning length is to be programmed, continue with the following steps. 12. Turn off partial decodes using the ~Lp0 command. 13. Display additional results in ScanVision through the Advanced Menu. 14. ** Place a sample of a bar code that is to be analyzed on the farthest position towards the left end of the laser beam where the code is intended to be scanned.

16

Page 20

15. Analyze the code by clicking the ScanVision Report an Analysis Speedbutton. 16. Confirm the code is being read and analysis results are proper. If not, move the code to the right until acceptable analysis results are achieved. 17. Record the value of the “Hor Pos” value in the additional parameters for the acceptable analysis. This value will consist of four digits. This value will be used for the “Set Ladder Start Position” setting later in the procedure. 18. Move the code to the farthest position towards the right end of the laser beam where the code is intended to be scanned. 19. Similar to steps 15, 16 and 17, obtain an acceptable analysis and record the “Hor Pos” value for the acceptable analysis. This value will be used for the “Set Ladder Stop Position” setting later in the procedure. 20. Place the unit in Ladder mode through the Setup Menu. Place the proper values for the “Set Ladder Start Position” and “Set Ladder Stop Position” boxes during menu process. 21. Enable partial decodes if desired for this application. 22. The unit is now ready to operate for ladder bar code direction. *This step is not mandatory, but highly recommended. Scanner focus is dependent on the scan distance. Good focus maximizes the SV Series’s ability to detect printer errors and failures. If this step is omitted, take extra precaution in setting and measuring the scan distance. ** This procedure assumes the SV unit is mounted as shown in Figure 2 with the protruding surface up and the user is looking at the beam from behind the SV unit. In this orientation, the beam is sweeping from left to right.

Figure 4a – Good Reflectance Profile

Example of a “good” scan reflectance profile: a. Consistent amplitude b. Amplitude within yellow lines

Figure 4b – Bad Reflectance Profile Bar code signal amplitude out of range: above yellow line and also off the graph.

Bar code low reflectance points not in straight, consistent values.

17

Page 21

Adjusting Scanner Gain and Offset Scanner gain and offset adjustment via commands is available in SV units that have the “A” circled on the label that indicates focus distance. The adjustment capability is useful for adapting the unit to various material types and scanning angles during the setup procedure. Knowledge of RJS ScanVision software is required for best understanding of the following description. When setting SV scanner gain and offset, use ScanVision Reflectance Profile Mode as the guide to viewing signal levels. The object is to have at least 6 lines high of signal amplitude for the bar code(s) being verified. The bar code signal vertical placement (offset) should be within the yellow lines to ensure the signal is in the linear range. All other objects’ amplitudes and placements are not important. A picture of a “good” signal level is shown below in Figure 5. To adjust gain and offset settings, first use the ScanVision Transmit SV Commands Screen to send a ~HT command to the SV unit. In the reply, look for the line that reads [DACs] = nnn nnn nnn nnn where nnn = numeric values. Example: a unit may read: [DACs] = 201 146 255 255. This indicates the current settings. 1. The 201 indicates the value of the gain setting. The higher the value, the higher the gain and therefore the higher the amplitude of the scan profile for a symbol. Max value is about 225. 2. The 146 value indicates the offset setting. The higher the value, the lower the symbol placement is offset on the graph. 3. The command ~Hd101nnn sets gain where nnn is the three digit value. 4. The command ~Hd201nnn sets offset where nnn is the three digit value. 5. Use these commands to set the desired signal amplitude ( ~Hd101nnn) and locate the signal vertical placement between the yellow lines ( ~Hd201nnn.) 6. A few iterations of commands will probably be needed, therefore it will be necessary to access the Transmit SV Commands Screen and Reflectance Profile Mode alternately. Note: A short cut to the Reflectance Profile Mode is accessed by pressing F3. 7. Like most other SV commands – new scanner settings are enabled immediately when received, but to be stored to non-volatile memory so they are maintained on a power up condition, the ~Hx command must be transmitted after the desired settings are achieved. Figure 5 – Desired Signal Amplitude and Placement

1. Bar code signal amplitude at least 6 lines high. (A more preferred 7 lines high is shown in this example). 2. Bar code signal placement within the yellow lines.

18