Spec sheet · HHP
HHP SV 100 and RJS SV 100 Spec Sheet
Spec sheet2 pagesPDF 56 KB
Both pages are below, each with its text.
Covers · 2 models
The models it covers
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
A two-page RJS spec sheet for the SV Series of fixed position scanner/verifiers, which lists the SV100, SV100HD, SV100C, SV200-1 and SV200-2. It explains on-line ANSI method verification and setup with RJS ScanVision software, and gives the ports, power, size, symbologies, quality parameters and accessories.
- Device
- Fixed position scanner and high-speed on-line ANSI method verifier for linear bar codes p. 1
- Serial port
- DB-9 male, RS 232C, programmable baud rate up to 115200 baud p. 2
- I/O port
- DB-15 male I/O-Power port with five programmable outputs (such as No Read, Poor Quality, Good Quality, Good Read) and two sync inputs p. 1, 2
- Power
- +5VDC at 1 amp p. 2
- Package
- 4.4 in. (112 mm) x 2.4 in. (61 mm) x 5.2 in. (132 mm) p. 2
- Symbologies
- USS Code 39, USS Code 128, USS Code 93, USS Codabar, USS Interleaved 2 of 5, UPC/EAN with 2 and 5 digit supplementals p. 2
- Setup software
- RJS ScanVision PC software over the serial port; Model SV download language for setup without ScanVision p. 1
- Operation modes
- Sync (edge and envelope), Freescan and ScanVision off line p. 2
- Ladder codes
- Up to four bar codes across p. 2
- Mounting
- Two sets of mounting holes on two surfaces, or a clamp for a 3/8 in. (9.5 mm) rod p. 2
- Accessories
- Universal power supply unit, ScanVision software, female DB-9 to female DB-9 cable (6 ft., 1.8 M), calibration symbol, mounting stand, rastering scan line, Zebra and Sato printer interface kits, power supply/sensor/output cable p. 2
- Quality data
- Decoded data, ANSI overall symbol grade and parameter grades, PCS, quiet zone analysis, X dimension, pass/fail flag, data match up to ten fields p. 2
What this sheet walks you through
- Setting up the scanner/verifier with RJS ScanVision while off line p. 1
- Watching bar code quality in real time while the unit runs p. 1
- Sending decoded data and quality data to a host without ScanVision p. 1
- Using the diagnostic data when installing or after conveyor or printer maintenance p. 1
Good to know
- All reflectance parameters need calibration, a fixed scanning distance and a fixed scan angle. p. 2
- The X dimension reading needs a fixed scanning distance. p. 2
- Mount the unit at its specified focus distance for the most accurate verification. p. 2
Questions this sheet answers
What interface does the RJS SV100 scanner/verifier have?
A DB-9 male RS 232C serial port with a programmable baud rate up to 115200, and a DB-15 male I/O-Power port. p. 2
What power does the SV100 need?
+5VDC at 1 amp. p. 2
What software sets up the RJS SV series?
RJS ScanVision, a PC based package for setup and monitoring; the Model SV download language also allows setup without it. p. 1
Which bar codes does the SV100 verify?
USS Code 39, Code 128, Code 93, Codabar and Interleaved 2 of 5, plus UPC/EAN with 2 and 5 digit supplementals. p. 2
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
RJS SV SERIES of SCANNER/VERIFIERS The SV Series of scanner/verifiers by RJS provides both fixed position scanning and high-speed on-line ANSI method verification of linear bar codes. This unique instrument can be used for many types of bar code scanning and/or verifying applications. The SV Series assures that bar code print quality is at an acceptable level. It checks to make sure the print mechanism has not failed or gone out of adjustment during operation. It even makes sure that the correct data is encoded and that the encoded data is in the proper format. The SV SERIES of SCANNER/VERIFIERS are ON-LINE VERIFIERS The SV Series analyzes and reports virtually every verification parameter known. ANSI and Traditional print quality parameters are transmitted along with decoded data. The reported symbol quality parameters ensure the print method or complete bar code process is optimized. This is important for ISO corrective action procedures, label manufacturing and printing, tracking systems, ink jet applications and more. The SV SERIES of SCANNER/VERIFIERS are FIXED POSITION SCANNERS The SV Series can operate as a fixed position scanner. But, since it also provides diagnostic bar code quality information, it can reduce system downtime and save material costs. It does this by isolating the source of the problem. Once the source of the problem is found, it can be corrected before non-readable bar codes are printed and material is wasted. The diagnostic capability is also useful when installing the scanner or after a conveyor or printer maintenance cycle. The available print quality information gives an indication of first time read rates, optimal scanner alignment, optimal conveyor speed and optimal printer settings and adjustments. In short, everything that is needed to ensure proper set-up of a system. EASY SETUP / FLEXIBLE INTERFACE The SV Series uses a serial port to interface with RJS ScanVision, a PC based software package used for set-up and monitoring. Use ScanVision for SV setup while the scanner/verifier is off line and/or use it for real-time bar code quality analysis while the scanner/verifier is operating. The unit also incorporates Model SV download language for setup without RJS ScanVision. Five hardware outputs are available via an I/O-Power port for logic operation such as No Read, Poor Quality, Good Quality or Good Read status. Two synchronization inputs are also available for robust No Read evaluations. Two LED’s are available for status indications. The serial port can also be used without ScanVision to provide decoded data and/or bar code analysis information to a host system.
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
RJS MODEL SV SERIES SYSTEM DESCRIPTION and TECHNICAL DATA SV Series Model Specifications* Analyses/sec Beam Width Focus Distance X dim (min)
SV100 100 6” (152mm) 8” (203 mm) .0067” (.17mm)
SV100HD 100 4.5” (114mm) 6” (152mm) .005” (.127mm)
SV100C 100 10.5” (267mm) 15” (381mm) .013” (.33mm)
SV200-1 200 2.5” (63.5mm) 8” (203mm) .0067” (.17mm)
SV200-2 200 1.75” (44mm) 6” (152mm) .005” (.127mm)
- Contact RJS Technical Support for information on custom and other models
Accessories and Options Universal Power Supply Unit, RJS ScanVision Software, Female DB-9 to Female DB-9 Communication Cable (6 ft. (1.8 M) length), Calibration Symbol, Mounting Stand, Rastering Scan Line, Interface Kits for Zebra and Sato Printers (contact RJS for additional printer types), Power Supply/Sensor/Output Cable. Data and Quality Parameters Available** Decoded Data, All Symbol Characters, Modulo Check Digit Analysis, Symbology Type, ANSI Method Overall Symbol Grade, ANSI Method Parameter Grades, (Reference Decode, Decodability, Modulation, Symbol Contrast, Rmin/Rmax, Defects, Min. Edge Contrast and Global Threshold), Average Bar Deviation, Ratio (if applicable), PCS, Element Reflectance (min. and max.), Quiet Zone Analysis, X Dimension, Inter-Character Gap (if applicable), No Read Flag, % decode, Partial Read Analysis, Pass/Fail Flag, Data Match (up to ten (10) fields), Increment/Decrement (base 10 and base 36). ** Note: 1. All reflectance parameters require calibration, fixed scanning distance and fixed angle of scan 2. X dimension requires fixed scanning distance
Symbologies USS Code 39, USS Code 128, USS Code 93, USS Codabar, USS Interleaved 2 of 5, UPC / EAN including 2 and 5 digit supplemental codes (Contact RJS for special symbology applications.) Scanning Performance Depth of Field – Mount at specified focus distance for most accurate verification operation. Ladder or Picket Fence Bar Codes Up to four (4) bar codes across Operation Modes Sync (edge and envelope), Freescan and ScanVision off line modes can be enabled Physical Package: Indications: Comm Port: I/O-Power: Mounting:
SVSeries-090800
4.4” (112 mm) x 2.4” (61 mm) x 5.2” (132 mm) Five (5) LED’s – Power/Sync, Calibration, Read, two (2) programmable LED’s DB-9 male, RS 232C, programmable baud rate up to 115200 baud DB-15 male, five (5) programmable outputs, two (2) sync inputs +5VDC @ 1 amp required Two (2) sets of mounting holes on two (2) different surfaces or a clamp for tightening to a 3/8” (9.5 mm) rod.