A.6 SCANTEAM 8310 Software Operation

The SCANTEAM 8310 supports keyboard wedge interfaces, wand emulation, and an RS-232 connection out the host port.

Keyboard Wedge Interfaces:

PC AT/XT/PS2

NCR 7052

IBM 3471, 3472, 3476, 3477, 3151, 3161, 3162, 3163, 3179, 3180, 3191, 3192, 3196, 3197

Harris H180, 191

Additional Host Interfaces Supported:

True RS-232 Serial Communications (PC comm port compatible) Wand Emulation

Note: Depending on the interface an external power pack may be required.

A.6.1 RS-232 Host Communication Parameters:

Baud rate, start and stop bits, and parity are programmable parameters for the host serial RS-232 interface. Refer to the SCANTEAM 8310 Programming Menu for instructions on how to modify the parameters from the default settings listed in the table which follows.

Serial RS-232 Host Communication Default Parameters:

Baud Rate: ............... 9600 bps

Character size: .......... 7 bits

Start bits: ... 1

Stop bits: ... 1

Parity: 20... . eee eee eee Even

Signal Level: ............. True RS-232 (+/- 8VDC)

Other baud rate options are: 300, 600, 1200, 2400,4800, 9600, 19.2K, 38.4K. Other parity options are: Odd, Mark, Space, and none.

A-14 Appendix A

Page 92 read from a scan by OCR; it may hold reading errors

A.6.2 Communication Protocols

There are four choices available in the SCANTEAM 8310 Programming Menu for the SCANTEAM 8310’s Main Port Protocol:

End of Record

60ms Timeout

Tranz 330™ Protocol Zon Jr.™ Protocol.

These selections are detailed in the following pages.

A.6.2.1_ End of Record and 60ms Timeout

The following describes how the SCANTEAM 8310 main port operates using the End of Record or 60ms Timeout protocols. (Please refer to the Terminal Selection and Main Port Configuration sections in the 8310 Programming Menu to program the SCANTEAM 8310 for an RS-232 terminal and End of Record or 60ms Timeout protocol.)

The RS-232 port is controlled by a serial communications polling scheme. A simple RTS/CTS hardware flow control is utilized. The End of Record and 60ms Timeout protocols are as follows:

a) Assert RTS of selected port to allow data input.

b) Wait 5ms for data input to be seen.

c) Ifno data comes in during this time, de-assert RTS then return to step a).

If data comes in during this time, wait for the end of record. (The end of record is indicated either by the End Of Record character programmed using the 8310 Programming Menu, or by a 60 ms delay between characters.) De-assert RTS, send to host terminal, then return to step a).

Appendix A A-15

Page 93

Notes:

S

S

S S

There can be no more than a 15 second intercharacter delay for characters in a data record. A timeout resets the data buffer, and all previous data for that record is lost. Data records greater than 255 bytes cause a buffer overflow. This resets the data buffer, and all previous data for that record is lost. Parity and framing errors cause the SCANTEAM 8310 to error beep and to ignore the data record. Data sent to the SCANTEAM 8310 while the 8310 has RTS de-asserted will be lost.

Tranzt 330 Protocol #*''*2&)$ !". %*2 /%" +*-/ *# /%" 0.&)$ /%" - +-*/* *' -"#"- /* /%" /&*) ." /&*). &) /%" /* /%" #*/%" - +-*/* *' /%" *# /%"

A.6.2.2

- +-*/* *' -",0&-". /%" /%" %*./ +*-/ ")! *# -" *-! #-*( /%" - &. -" *$)&5"! 0/&'&5&)$ /%" -(. /&("*0/ +-*/* *' &. #*''*2.

.")!. 2%"-" &. /%" *# /"-. /%"

"3+" /"! -".+*)." /* &. *- *- &. )*/ -" "&1"! 2&/%&) ." *)!. /%" &. /* "+/"! &. -" "&1"! /%" &. -"6.")/ /%" /%&-! /%" $&1". 0+ ")/"-. &/. '**+

Notes:

S

S

S

A–16

There can be no more than a 15 second intercharacter delay for characters in a data record. A timeout resets the data buffer, and all previous data for that record is lost. Data records greater than 255 bytes cause a buffer overflow. This resets the data buffer, and all previous data for that record is lost. Parity and framing errors cause the SCANTEAM 8310 to ignore the data record. Appendix A

Page 94 read from a scan by OCR; it may hold reading errors

A6.2.3 Zon™ Jr. Protocol

The following describes how the main port of the SCANTEAM 8310 operates using the Zon Jr. protocol. (Please refer to the Terminal Selection and Main Port Configuration sections in the 8310 Programming Menu to program the SCANTEAM 8310 for the Zon Jr. protocol, and the baud rate and parity of the Zon Jr.)

The Zon Jr. protocol requires that the SCANTEAM 8310 has the host port RS-232 hardware. The end of a data record from the Zon Jr. is recognized by utilizing the 60ms delay timeout. The protocol is as follows:

a) TheSCANTEAM 8310 sends <ENQ> to tell the Zon Jr. that it has data.

b) The SCANTEAM 8310 waits for <ETX><NUL> which tells it that data can be sent.

c) The SCANTEAM 8310 sends data <STX>data<ETX>LRC where LRC is the XOR of all characters after the <STX>. (If a MICR read error occurred, the data would be a single “2” character.)

d) The expected response to data is <ACK> or <NAK>. If <ACK> or <NAK> is not received within 2.5 seconds the data is assumed to be accepted. If a <NAK> is received, the data is re-sent. After the third <NAK>, the SCANTEAM 8310 gives up and enters its normal operating loop.

Notes: ¢ Therecanbeno more than a 15 second intercharacter delay for characters in a data record. A timeout resets the data buffer and all previous data for that record is lost.

e Data records greater than 255 bytes cause a buffer overflow. This resets the data buffer, and all previous data for that record is lost.

¢ Parity and framing errors cause the SCANTEAM 8310 to ignore the data record.

Appendix A A-17

Page 95 read from a scan by OCR; it may hold reading errors

A.6.3 Displaying the Firmware Part Number and Revision Level

The revision level of the firmware operating in the SCANTEAM 8310 is embedded in the part number assigned to that firmware. The SCANTEAM 8310 displays the firmware revision level on the host terminal when commanded to do so during programming.

The programming commands are initiated by scanning bar codes from the SCANTEAM 8310 Programming Menu (if the SCANTEAM 8310 has been connected to an RS-232 device), or by passing the Status programming check through the check reader. Refer to the STATUS CHECK section in the SCANTEAM 8310 Programming Menu for the software revision display command sequence.

When a status is programmed, the current software revision level is flashed on the host display. Four digits flash. The first three digits displayed are the current revision level of the software. The last digit indicates the state of the reader (refer to the Error Code chart on page A - 19).

A.6.4 PC Upload/Download Using Quick*Load

The SCANTEAM 8310 contains reprogrammable memory that contains the operating system for the 8310. This memory is a type of Read Only Memory (ROM) called flash memory. Flash memory can be electronically erased and reprogrammed like typical RAM, but does not lose its contents when power is lost.

When the SCANTEAM 8310 must be upgraded or modified, new operating system (firmware) or parameter data files must be placed into its flash memory. This is done using a special protocol, designed specifically for this purpose. The Welch Allyn software tool called Quick*Load is designed to implement the protocols used by the Welch Allyn flashable devices making it easy for users to download and upload firmware and run diagnostics on SCANTEAM products. Please refer to your Quick*Load manual for further information about using Quick*Load with your SCANTEAM 8310.

Appendix A

Page 96

A.7 MICR Data Formatter A.7.1

Error Condition Reporting

A.7.1.1

LED Display Error Codes and Single Character Host Error Codes

- '# #"

&# #" '# - ('$(' %%#% #"

Appendix A

A–19

Page 97

Condition

Single Error Code Sent to Host

Good power-up initialization Good E13-B read Canadian check No account number Business check (unless Canadian) Travelers check No sequence number (unless Travelers check) Serial number less than 300 Old U.S. Check Good CMC-7 read Bad check - no MICR Low signal level High signal level Initial power-up calibration Power up initialization error Questionable MICR character Program mode Format error Check unreadable Exception Formatting Error Magnetic Interference

Double Error Code Sent to Beep Host Sequence none none none none none 00 01 03

1 beep 1 beep 1 beep 1 beep none none

08 12

1 beep 1 beep none none none none N L H none F E none Y see list pg. 5–9 J none

11 15 04 00 09 10 none none none 06 none 11 none 11 none

1 beep 1 beep 1 beep 1 beep 3 beeps 3 beeps 3 beeps 3 beeps 3 beeps 3 beeps 2 beeps 3 beeps 3 beeps 3 beeps none

Unreadable (U) error codes: 0 1 2 3 4 5 6 7 8 9 A–20

Auxiliary On-Us field error (not bounded by On-Us symbols) Invalid EPC character Missing transit symbol Wrong number of digits in transit field Mod 10 check digit failure More than 24 characters in On-Us field No On-Us symbol in On-Us field No On-Us field Wrong number of digits in amount field Missing amount symbols Appendix A

Page 98 read from a scan by OCR; it may hold reading errors

A.7.2 Pre-Canned Format 10 - Error Code Reporting

The SCANTEAM 8310 has a selection of nine “pre-canned” host interface output data formats. (Refer to the SCANTEAM 8310 Programming Menu, MICR Data Formatter section, for a list of “pre-canned” output formats.) The pre-canned formats provide additional status information which can be sent to the host device. The host application must be capable of supporting the error codes as defined, since they are not configurable in the check reader. If a pre-canned format with extended status and error reporting is selected, the error and status codes cannot be modified, and the codes in the table on page A - 22 are sent to the host.

The MICR Data Formatter output format number 10 provides detailed MICR document status and error reporting capabilities which are not currently available in any other output data formats.

Appendix A A-21

Page 99

( (.-).- -( "(,- 3 #, #, good checks bad checks

Return Code Sent to Host

Note:

A–22

- 0#-"

0#-"

Search Order

Description

09 10 06 11 05

No MICR Low signal Bad data/unreadable character Parsing error/Non-North American format Invalid ABA check digit

1 2 3 4 5

00 01 03 08 12 02 15 04

Good personal check Canadian check No account number Business check (unless Canadian) Travelers check No sequence number (unless Travelers check) Serial number is less than 300 Old U.S. Check

6 7 8 9 10 11 12 13

If the SCANTEAM 8310 detects more than one Return Code for a good check, the last Return Code encountered in the search order appears on the host display. For example, if a check is Canadian (code 01) but has no account number (code 03), the 03 code is displayed on the host terminal. This is because the no account number (code 03) is 8th in the search order and the Canadian check (code 01) is 7th in the search order.

Appendix A

Page 100 read from a scan by OCR; it may hold reading errors

INTRODUCTION TO MICR CHECK B READING AND MICR TECHNOLOGY

B.1 MICR Definition and Techniques

MICR is an acronym for Magnetic Ink Character Recognition. A check reader’s function is to read the information printed on the bottom of a business check or personal check and to transmit that information to a host device. This line of information is called the “MICR Line” because the ink used to print the MICR characters contains iron particles and is magnetic. The characters printed with the magnetic ink are read using Magnetic Ink Character Recognition technologies.

Check readers read the characters using either optical character recognition technology (OCR), or magnetic read head technology. Early check readers intended for retail point of sale applications used OCR techniques to read the MICR line. The ability to defraud an OCR check reader using a pen or pencil has caused this technique to be rejected by the market due to the susceptibility to fraud.

All the popular check readers sold today for retail applications are based on a technique which uses a magnetic read head to pick up a signal from a document containing magnetic ink which is passed beneath the read head.

Appendix B B-1