Page 41

INSTALL_to_Wand

This control mode is used to program the Wand to desired operating parameters. When this option is highlighted and the ENTER key is depressed, the Wand configuration will be programmed to the decoding selections and variables displayed on the Menu. You will be prompted to identify the serial port (COM1 or COM2) the 6180 is attached to. –EXIT–

This command will terminate the WANDMENU routine. When EXIT is highlighted and the ENTER key is depressed, control of the Programming Menu will end and the DOS prompt will be displayed. 4.7.3 Programming Control The programming menu is controlled from the PC keyboard using the ( ), ( ), ( ), ( ) arrows on the number pad and the ENTER key. The arrow keys move you around the screen and ENTER toggles through acceptable setting except in a few special cases which will be explained later in this section. The active menu element, (the control option and the specific decoder parameter) is indicated by the position of the cursor. A decoder operating parameter (selection and variable) must be highlighted before it can be changed. Arrow Keys

In addition to moving the cursor around the menu to the desired position, in ) and ( ) arrows control a counter which certain positions, the ( causes that particular menu field to increment through the range of acceptable programming selections. For example, when the cursor is positioned so Minimum Code Length is highlighted, depressing the ( ) key will cause the menu to sequentially display the complete range of allowable minimum character values for that particular symbology. ENTER Key

The ENTER Key also performs several functions. It is used to: 1) initiate the highlighted function, 2) toggle certain menu selections ON or OFF, and 3) cycle through a range of certain menu parameters.

Programming the Scanner

4–17

Page 42

Toggle – The ENTER key will “toggle” ON/OFF menu selections such as wand Indicators and Features, individual symbologies, and bar code variables such as start/stop and check characters. Cycle – Depressing the ENTER key when the cursor is positioned at Baud Rate, Parity and Intercharacter Delay will cause the menu to cycle (increment) through the range of allowable values for those parameters. Record – When a decoder selection has been made and the ENTER key is depressed the value displayed at the highlighted menu selection will be temporarily stored and the cursor will be freed to advance to the next menu selection. For example, if a Preamble consisting of STX and Code ID characters has been specified, depressing the ENTER key will cause those values to be stored. The ( ) key can then be used advance the cursor to the next menu selection, Postamble. 4.7.4 Making Menu Selections The following sections explains the functions of the ENTER and the four arrow keys as they relate to specific menu selections. Start–Up

At start–up, the cursor will automatically default to the LOAD Settings ) once will control option and it will be highlighted. Depressing the ( move the cursor down the menu to the BaudRate position. Note that the Default value for baud rate is 9600. Baud Rate

The following example explains the use of the ENTER key to increment menu Baud Rate selections and configure the Wand to operate at 2400 baud. When the cursor has been positioned on the BaudRate menu line depressing the ENTER key will cause the baud rate to cycle through allowed values. For example, from the default setting of 9600 baud, depressing the ENTER key six (6) times will cause the rate to increment to 2400 baud.

4–18

Programming the Scanner

Page 43

To record this programmed value simply advance the cursor to the next menu line by depressing the ( ) key. The baud rate setting which is displayed can then be SAVED or INSTALLED in the wand by using the appropriate control option. In a similar manner, the ENTER key is used to increment the menu selections Parity and Inter–Character Delay through their range of available values. Preamble/Postamble

Just like configuring with the Bar Code Chart up to five (5) preamble and postamble characters may be added to bar code messages. The ( ) or ( ) keys are used to position the cursor on the desired menu line. Note that the default value for the first Preamble character is Code ID, [ID] and that all the remaining preamble selections are vacant. The ENTER key is used to specify which of the preamble or postamble characters will be programmed. Once a preamble/postamble position is “active,” the ( ) and ( ) keys are used to increment that preamble and postamble selection through the range of available values. To change the default value or to program additional preamble characters depress the ENTER key. The first character, [ID], will be highlighted indicating it is an “active” element. Depressing the ( ) or ( ) keys will increment the first preamble character through the full range of acceptable characters. When the desired value is displayed, move the cursor to the second preamble position (if a second preamble character is required) by depressing the ENTER key. Both the first and second preamble character positions will now be highlighted. The second preamble character can now be selected by using the ( ) or ( ) keys to increment the characters until the desired value is displayed.

Programming the Scanner

4–19

Page 44

The remaining preamble characters (if desired) should be selected using the same technique. When the desired preamble is displayed, depressing the ENTER key will cause the recorded values to be displayed with vacant preamble positions indicated by (– – –). When the preamble/postamble has been programmed, the cursor can be moved to a different menu line by depressing the ( ) or ( ) key. Indicators

The following example explains the use of the ENTER to “toggle” decoder Indicator functions “Wake–Up Blink” and “Good Read Blink” ON and OFF. Both of these wand Indicator selections default to the ON state at start–up. Use the ( ) or ( ) key to position the cursor at the Indicator menu line. The selection “Wake–Up Blink ON” will remain highlighted indicating it is the “active” menu element. Depressing the ENTER key once will cause the selection to “toggle” to Wake–Up Blink OFF, the disabled state. Depressing the ( ) key will move the cursor to the “Good Read Blink” selection. This selection can also be “toggled” ON or OFF using the ENTER key. Remember, that the “Blink Scanner” selection must also be ON (enabled) whenever the “Wake Up” or “Good Read” indicator functions are desired. When Indicator selections have been made, leave the Indicator menu line by depressing the ( ) key. The cursor will move down to the menu line labeled Features, and the selected indicator states will be displayed. The same ENTER/“toggle” technique is used to configure Wand Features and the message format options such as Start/Stop CHAR, and Check CHAR, which are associated with each of the bar code symbologies. Symbology and Code Option Selections

The Default setting for all bar code symbologies is ON. Individual symbologies can be toggled ON/OFF by depressing the ENTER key. In the case of UPC, EAN and Code 128, the ENTER key is used to cycle these symbologies ON/OFF through all acceptable combinations.

4–20

Programming the Scanner

Page 45

The ( ) and ( ) keys move the cursor left and right to the individual code option selections. The ( ) and ( ) keys are used to position the cursor on the desired symbology line and increment to minimum and maximum word length through the range of available values. Code Length – When the cursor is positioned so the complete length option (i.e., Length = 01–48) is highlighted depressing the ENTER key once will cause the minimum character length to become active (highlighted). Use the ( ) and ( ) keys to increment to the desired value. Then depress the ( ) key to position the cursor at the maximum character length. ) key to increment When this menu position is highlighted, depress the ( to the desired value. After the proper minimum and maximum code lengths are displayed, depress the ENTER key. The complete length option will again be highlighted and the programmed value will be retained. If additional code options are to be selected, move the cursor to the desired position using the ( ) key. Code Options – All of the code options (such as S/S, CC, etc.) are selected by “toggling” them ON or OFF using the ENTER key. Movement between code options is accomplished using the ( ) and ( ) keys.

Programming the Scanner

4–21

Page 46

4–22

Programming the Scanner

Page 47

5

MAINTENANCE AND TROUBLESHOOTING

5.1 Scanner Maintenance And Service All Welch Allyn SCANTEAM 6180 units are designed to provide reliable and efficient operation with a minimum of care. Although specific maintenance is not required, the following periodic checks will contribute significantly to dependable scanner operation.

5.2 Cleaning All Welch Allyn SCANTEAM 6180 units are designed to provide reliable and efficient operation with a minimum of care. Although specific maintenance is not required, the following periodic checks will contribute significantly to dependable scanner operation. The sapphire tip is designed to be maintenance free, but may be cleaned when necessary. The tip of the scanner must be kept clean to assure high first pass reading performance. Since a dirty tip can impair scanning performance, the tip should be examined whenever scanning performance begins to degrade or if the tip has become visibly dirty. If the tip becomes dirty, it should be cleaned by wiping with a soft cloth or facial tissue that has been dampened with a mild detergent and water solution. The scanner enclosure can also be cleaned using the same procedure. Note:

DO NOT use abrasive tissues or wipers as these will scratch the tip. NEVER use solvents (ie. alcohol or acetone) on the tip or to clean molded handle scanners since these may damage the finish.

Maintenance and Troubleshooting

5–1

Page 48

5.3 Inspection Cords And Connectors The scanner cord should be inspected periodically for wear and other signs of damage. A badly worn cord may interfere with the proper operation of the unit and may require replacement of the scanner. The scanner connector can be repaired/replaced by Welch Allyn. Scanner Case The scanner enclosure should also be routinely examined for signs of damage. A badly dented enclosure may contact internal components and result in damage to or malfunction of the unit.

5.4 Troubleshooting If the scanner fails to operate properly, perform the following checks: 1)

Check the scanner interface cable connection to make sure it is properly attached to the host P.C.

2)

Confirm that the decoder is properly configured for the bar code symbology.

3)

Inspect the quality of the bar code symbols that are being used. Symbols that are of a low contrast, scratched or otherwise defaced may cause scanning problems. To verify scanner operation, test the system with a high quality bar code symbol. As an additional check, verify the quality of bar code symbols with a bar code verifier such as the Quick Check, available from Welch Allyn.

4)

Check the condition of the scanner tip. If the tip is scratched, the scanner may not read properly. If the tip is broken or cracked, the optics may also become damaged by dust or other foreign matter. Should either of these conditions be present, replace the scanner tip. The tip can be removed by inserting a thin coin into the tip locking ring and prying it off the end of the scanner.

5–2

Maintenance and Troubleshooting

Page 49

Do not touch or make contact with the exposed lens surface as permanent damage to the scanner optics may result. Welch Allyn recommends keeping a supply of spare tips on hand. If replacing the tip does not correct the scanning problem, it may be necessary to replace the entire wand unit. Note:

Other than the replaceable tip, the wand scanner contains no user serviceable parts and, therefore, the scanner case should not be opened. Opening the scanner voids the warranty.

If proper wand operation cannot be obtained after performing these checks, factory service may be required.

5.5

Obtaining Factory Service in the United States

Welch Allyn provides service for all its products through a service center located at its manufacturing facilities in Skaneateles, New York. To obtain warranty or non–warranty service, return the unit to Welch Allyn (postage paid) with a copy of the dated purchase record attached. Please contact the Welch Allyn Product Service Department at the address/telephone number listed below to obtain a Return Material Authorization number (RMA #). Welch Allyn, Inc. Data Collection Division Product Service Department 4619 Jordan Road P.O. Box 187 Skaneateles Falls, New York 13153–0187 Product Service Department Telephone: (315) 685–4278 or 685–4360 Fax: (315) 685–4156

Maintenance and Troubleshooting

5–3

Page 50

5.6 Obtaining Factory Service in Europe For service in Europe, please contact your Welch Allyn representative (at appropriate address below) or your local distributor. Welch Allyn, Ltd. Block 1, Bracken Business Park Sandyford Co Dublin Ireland Telephone: Int+353–1295–0750 Fax: Int+353–1295–6353

U. K. Office Dallam Court Dallam Lane Warrington, Cheshire WA2 7LT England Telephone: Int+44 1925 240055 Fax: Int+44 1925 631280

5.7 Obtaining Factory Service in Asia For service in Asia, please contact your Welch Allyn representative (at address below) or your local distributor.

Welch Allyn, Hong Kong Office 10/F Tung Sun Commercial Centre 194–200 Lockhart Road Wanchai, Hong Kong Telephone: Int+852–2511–3050 or 2511–3132 Fax: Int+852–2511–3557

5–4