The text of a manual · part 1 of 2
SCANTEAM 6180 Wand Programming Menu, pages 1 to 9
Pages 1 to 9 of 18
The original document is the PDF (96 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP ST6180
Page 1
WelchAllyn:
SCANTEAM® 6180 WAND
Programming Menu
Page 2
SCANTEAM 6180 Programming Menu
NOTES
Please Note: The programming features on each menu page are not supported in all models and software revisions of the SCANTEAM 6180. Notations are included if the feature is available only in certain models. Contact your Welch Allyn Sales Coordinator for the revision/model to fit your needs. The SAMPLE BAR CODES page (near the end of the programming menu) contains bar code symbols that you may use to verify that you have programmed your SCANTEAM 6180 correctly.
Disclaimer Welch Allyn reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult Welch Allyn to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of Welch Allyn. Welch Allyn shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material.
This document contains proprietary information which is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of Welch Allyn, Incorporated. 1999 Welch Allyn, Inc. All rights reserved. Data Collection Division Web Address: http://dcd.welchallyn.com
Page 3
STATUS
SCANTEAM 6180 Programming Menu
CHECK
SHOW FIRMWARE REVISION LEVEL Scan the bar code below to display the revision level of the SCANTEAM 6180 firmware.
For example: After scanning the Firmware Revision Level bar code, “(C) WA93C” is output to the terminal/host device. The “C” at the end indicates the firmware is at revision level C.
Firmware Revision Level
SHOW SOFTWARE NUMBER Scan the bar code below to display the SCANTEAM 6180 software number. The resulting information will show if there is a special or custom download program resident in the scanner.
For example: After scanning the Software Number bar code, “33962001” is output to the terminal/host device. That number is the software number.
Software Number
SCANNER LABELING The drawing below shows the serial number label that is attached to the scanner cord. The top number shows the SCANTEAM 6180 model number. This may also be a special 6 digit part number (custom orders). The serial number is on the second line. The “C” after the serial number indicates that the firmware Mask revision is C.
6180/J–2115N J01 1234C
3
Page 4
USER’S NOTES
4
SCANTEAM 6180 Programming Menu
Page 5
SYSTEM
SCANTEAM 6180 Programming Menu
GUIDE
USE THIS PAGE As a general overview of the programming menu. The programming menu consists of two basic components as shown below. SELECTION II (RETAIL) USE THIS PAGE
BAR CODE CHART
Programming Menu
CODE
Programming Menu
USE THIS PAGE In combination with the adjoining menu pages to program the unit. The bar codes on this page correspond to symbols in shaded areas on adjoining menu pages. SCAN these bar codes in the sequence indicated on menu page to program desired selections and variables.
ROMAN NUMERALS
LETTERS
DIGITS
OTHERS
To select the pre–programmed asterisked (*) values by scanning DEFAULT symbol. To enable or disable listed code selections.
scan
I selections
ENTER scan scan scan
Version A Version D(2) Version E0 Version E1 Check Digit Xmit Number System Xmit Version E Expand 2–Digit Addenda 5–Digit Addenda
A B C D E F G H I
*Yes/No No* *Yes/No *Yes/No *Yes/No *Yes/No Yes/No* *Yes/No *Yes/No
A B C D E
*Yes/No *Yes/No *Yes/No *Yes/No *Yes/No
UPC ID = c (HEX 63)
EAN ID = d (HEX 64)
EAN/JAN 13 EAN/JAN 8 Check Digit Xmit 2–Digit Addenda 5–Digit Addenda
UPC & EAN Addenda Req’d. MSI ID = g (HEX 67) Plessey ID = n (HEX 6E)
Enable scan
DEFAULT variables
A XI
II
ESCAPE 0 (YES)
B XII
III
DEFAULT 1 (NO)
C XIII
IV
W.A. 2
D XIV
3
Yes/No*
V
Enable Minimum Length Maximum Length
A B
Yes/No* *04–Max Min–48*
Enable Minimum Length Maximum Length
A B
Yes/No* *04–Max Min–48*
Notes: (1) * Designates DEFAULT selections. (2) UPC Version D is not supported at this time.
E XV
VI
4 F
XVI VII
5 G
XVII VIII
6 H
XVIII scan
IX
EXIT
X
7 I
XIX
8 J
XX
SAMPLE MENU PAGE
9
BAR CODE CHART
MENU PAGE Each menu page represents one section of the programming menu. Use individual menu pages in combination with the bar code chart on the back page foldout to program the decoder. USE THIS PAGE – is a summary of the programming options (parameters) of each menu page. ENTER – Each menu page has its own unique ENTER bar code; scan this bar code to activate desired menu page. DEFAULT – Most menu pages have a DEFAULT bar code which allows the user to independently default menu pages to astericked (*) values without affecting, in any way, the rest of the programming menu. Default values can be easily selected from the desired menu pages by scanning the bar code sequence ENTER, DEFAULT, EXIT. Individual defaults for a specific selection can be made by scanning ENTER, ROMAN NUMERAL, DEFAULT, EXIT. EXIT – To move from one menu page to another, scan the EXIT bar code. This bar code must be scanned to end programming selection on each menu page before beginning to program on a different menu page. SELECTIONS/VARIABLES – Lists all of the options available on each menu page. Following each option are symbols in shaded areas. These symbols correspond to bar codes on the adjoining bar code chart.
MENU PAGE FACING (Not Shown) The page facing the menu is often used to supplement or clarify the material presented on the front of each menu page. The information and examples found here are specific to the individual menu page and contain, in some cases, charts and diagrams that must be used in order to determine the correct programming sequence.
BAR CODE DATA CHART The bar codes on this chart are assigned to a ROMAN NUMERAL, DIGIT, LETTER OR YES/NO symbol. These bar codes correspond to the symbols in shaded areas on the menu pages and are scanned in various combinations to enter programming sequences to the decoder. Bar codes on this page are meaningless unless an ENTER bar code from one of the menu pages is first scanned. When an ENTER bar code is scanned, the bar code chart becomes specific to that menu page and remains so until the EXIT bar code is scanned or another menu page is selected.
ESCAPE W.A DEFAULT
Use this bar code to cancel current programming sequence. All parameters remain as they were. Scan ESCAPE. Used in conjunction with the DEFAULT bar code to set all decoder parameters to the DEFAULT values. Used in conjunction with the W.A bar code. The scan W.A followed by DEFAULT will set all decoder parameters on both menu pages to their DEFAULT value.
5
Page 6
INPUT/OUTPUT
SCANTEAM 6180 Programming Menu Information and Examples
PARAMETERS & FORMAT
Baud Rate – Baud rate is a means of expressing data transmission speed. This programming selection permits the user to select any of eight (8) values ranging from 150 to 19200 baud. Parity – Provides a means of checking character bit patterns for validity. The scanner can be configured to operate under Mark, Space, Even or Odd parity options. Preamble – When enabled, one or more characters are transmitted as a header immediately preceeding scanned bar code data. Up to five (5) preambles can be selected and will be transmitted in the order they are made. Postamble – Postambles are programmable data identifiers which follow the scanned bar code data. Up to five (5) postambles can be programmed. Intercharacter Delay – When enabled, an intercharacter delay of between 01 and 99 milliseconds can be programmed. Incoming messages may not have an intercharacter delay greater than (1) byte time at the programmed baud rate. Indicator Control – This programming selection provides control of the Beeper. When “Beep on Reset” is enabled, the Beeper will beep each time the system is reset. If “Beep on Good Read” is enabled, the Beeper will beep following a scan when the data has been accepted by the Host. Append Buffer – Controls state of Append Buffer. This buffer must be enabled if Code 3 of 9 symbology with Append Option has been selected. RTS/CTS – This selection on will require RTS/CTS handshaking protocol for RS–232 communication. Data Format – Provides a means to set data word length . The scanner may be programmed for 7 or 8 data bits and 1 or 2 stop bits. Low Power – When enabled, this programming selection puts the wand scanner in a low power mode. The LED will be pulsed to conserve power and will “wake up” when a transistion from black to white is seen.
PREAMBLE/POSTAMBLE Preambles and Postambles are characters added by the units to scanned bar code data. These characters are sent with the bar code data to the terminal. Use the Hex–ASCII table below to find the alpha–numeric code to be used for programming a particular Preamble or Postamble. To Clear Pre/Postamble: Scan: Enter, III (or IV), Default, and then EXIT. PROGRAMMING EXAMPLE To program a Horizontal TAB (HT) Postamble: Scan: Enter, IV, D, 0, 9, EXIT. HEX – ASCII CHART NUL 00 SOH 01 STX 02 ETX 03 EOT 04 ENQ 05 ACK 06 BEL 07 BS 08 HT 09 LF 0A VT 0B FF 0C CR 0D SO 0E SI 0F
6
DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
SP ! ” # $ % & ’ ( ) * + , – . /
20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F
0 1 2 3 4 5 6 7 8 9 : ; < = > ?
30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F
@ A B C D E F G H I J K L M N O
40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F
P Q R S T U V W X Y Z [ \ ] ^ _
50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F
‘ a b c d e f g h i j k l m n o
60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F p 70 q 71 r 72 s 73 t 74 u 75 v 76 w 77 x 78 y 79 z 7A { 7B | 7C } 7D ~ 7E DEL 7F
Page 7
INPUT/OUTPUT
SCANTEAM 6180 Programming Menu Programming Menu scan
ENTER
PARAMETERS & FORMAT
USE THIS PAGE To select baud rate and parity. To add preambles, postambles, and/or code identification character to the bar code. To set intercharacter delay to a specific value. To control scanning indicator (beep &/or blink). To enable the Append Buffer when Code 3 of 9 with append option is selected. To enable CTS handshake, Data Format, Low Power features.
selections scan
BAUD RATE
I scan
DEFAULT
PARITY
II
PREAMBLE (up to 5 chars)
III
POSTAMBLE (up to 5 chars)
IV
INTERCHAR. DELAY
V
INDICATOR CONTROL (4) VI APPEND BUFFER
VII variables scan scan
A
150 300 600 1200 2400 4800 9600 19200
B C D E F G* H
Mark Space Even Odd STX Code ID Other ASCII ETX CR LF Other ASCII
A B C* D A B* C A B* C* D
No Yes
A* B
*00–99
Beep on Reset
A
*Yes/No
Beep on Good Read
B
*Yes/No
LOW POWER (5)
scan
EXIT
IX
00–7F
*Yes/No
Enable
RTS/CTS PROTOCOL (3) VIII DATA FORMAT (5)
00–7F
Yes/No* 7 Data, Parity, 1 Stop (8 Bit Data)
A*
7 Data, Parity, 2 Stop (8 Bit Data)
B
8 Data, Parity, 1 Stop (9 Bit Data)
C
X
Yes/No*
Notes: (1) * Designates DEFAULT selections. (2) See facing page for more information and examples. (3) This programming feature is not supported in all models/software revisions. (4) This programming feature has been changed for Mask C. Refer to the cable labeling to determine which firmware you have. (5) Available with Mask C only.
7
Page 8
SYMBOLOGY SELECTION
SCANTEAM 6180 Programming Menu Information and Examples
INDUSTRIAL
INDUSTRIAL CODE OUTPUT FORMATS aSX . . . XS bSXX . . XXCS eXX . . . XXC fXX . . . . XX gXX . . . XX hXX . . . XXCC iXX . . . . XX jXX . . . . XX
CODABAR Code 3 of 9 INTERLEAVED 2 of 5 2 of 5 MSI Code 11 Code 93 Code 128 Where: a = Codabar Code ID b = Code 3 of 9 ID e = Interleaved 2 of 5 ID f = 2 of 5 ID g = MSI (Plessey) h = Code 11 ID i = Code 93 ID j = Code 128 ID S = Start/Stop Character X = Data Character C = Checksum Character
NOTE: Proper parameters must be turned on for code identification. Start/stop and Checksum characters to be transmitted. For maximum data security, disable the Codes not used.
FULL ASCII CODE 3 OF 9 CHARACTERS If full ASCII Code 3 of 9 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN and /C will be decoded as the ASCII character #. FULL ASCII CODE 3 OF 9 CHART NUL %U SOH $A STX $B ETX $C EOT $D ENQ $E ACK $F BEL $G BS $H HT $I LF $J VT $K FF $L CR $M SO $N SI $O
DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
$P $Q $R $S $T $U $V $W $X $Y $Z %A %B %C %D %E
SP ! ” # $ % & ’ ( ) * + , – . /O
SPACE /A /B /C /D /E /F /G /H /I /J /K /L – . /
0 1 2 3 4 5 6 7 8 9 : ; < = > ?
0 1 2 3 4 5 6 7 8 9 /Z %F %G %H %I %J
@ A B C D E F G H I J K L M N O
%V A B C D E F G H I J K L M N O
P Q R S T U V W X Y Z [ \ ] ^ _
P Q R S T U V W X Y Z %K %L %M %N %0
‘ a b c d e f g h i j k l m n o
%W +A +B +C +D +E +F +G +H +I +J +K +L +M +N +O p +P q +Q r +R s +S t +T u +U v +V w +W x +X y +Y z +Z { %P | %Q } %R ~ %S DEL %T%X%Y%Z
Character pairs /M and /N decode as a minus sign and period respectively. Character pairs /P through /Y decode as 0 through 9.
MIN/MAX LENGTH These variables are used to require that bar code symbols contain a character count within a certain range. Bar codes with counts outside this range will not be decoded. EXAMPLE: Decode only those bar codes with a count of 9–20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15
8
Page 9
SYMBOLOGY
SCANTEAM 6180 Programming Menu Programming Menu
SELECTION
(CODES) USE THIS PAGE To specify desired bar code symbologies. To select symbology options.
selections scan
CODABAR
CODE 39 scan (ID = a)
(ID = b)
I
II
ENTER scan
UPC
(ID =c )
III
DEFAULT
EAN
(ID = d)
IV
UPC &/or EAN INTERLEAVED (ID = e) 2 OF 5
V
CODE 2 OF 5 (ID = f)
VI
MSI CODE 93 CODE 128
CODE 11 (3)
(ID = g) (ID = i) (ID = j)
(ID = h)
VII VIII IX
X variables Enable Minimum Length Maximum Length S/S Xmit
EXIT scan
A B C
*Yes/No *01–MAX Min–48* *Yes/No
Enable Minimum Length Maximum Length S/S Xmit Check Char. Req’d Xmit Check Char. Full ASCII Append Option
D E F G
*Yes/No *00–MAX Min–48* Yes/No* Yes/No* Yes/No* *Yes/No Yes/No*
Version A
A
*Yes/No
Version E (Version E Expand) Number System Xmit Check Digit Xmit
B C D E
*Yes/No Yes/No* *Yes/No Yes/No*
EAN/JAN 13 EAN/JAN 8
A B
*Yes/No *Yes/No
2–Digit Addenda 5–Digit Addenda
F G
*Yes/No *Yes/No
Enable Minimum Length (2) Maximum Length 6, 14 & 16 Only Check Digit Req’d Xmit Check Char.
A B C D E
*Yes/No 02–MAX Min–64* Yes/No* Yes/No* Yes/No*
Enable Minimum Length (2) Maximum Length
A B
*Yes/No 02–MAX Min–64*
Enable Minimum Length Maximum Length
A B
*Yes/No *04–MAX Min–48*
Enable Minimum Length Maximum Length
A B
*Yes/No *00–MAX Min–60*
Enable (All Modes) Mode A Mode B Mode C Minimum Length Maximum Length Leading <FNC1> Req’d.
A B C D E F
*Yes/No *Yes/No *Yes/No *Yes/No *00–Max Min–80* Yes/No*
A
Yes/No*
Xmit Check Char.
B
Yes/No*
Minimum Length Maximum Length
C D
*01–MAX Min–48*
A B C
Enable 2 Check Digits (N=1)
scan scan
*Yes/No
Notes: (1) * Designates DEFAULT selections. (2) The DEFAULT Minimum Length for 2/5 codes is 4 Characters. (3) This programming feature is not supported in all models/software revisions.
9