Page 81
14
Default Charts
14.1
Tailoring the Terminal and Keyboard The following chart lists the factory default for the Tailoring the Terminal and Keyboard settings (indicated by a on the programming menu pages).
Default Setting
Page Reference
United States
Page 3-2
Keyboard Style
Regular
Page 3-3
Keyboard Style Modifiers
CTRL+ ASCII Mode Off
Page 3-4
Turbo Mode Off
Page 3-4
Parameter Name Country Code Selections Foreign Keyboards
Keyboard Selections
Numeric Keypad Mode Off Page 3-4
14.2
Configuring Output Parameters Defaults The following chart lists the factory default Output Parameter settings (indicated by a on the programming menu pages).
Default Setting
Page Reference
Primary Prefix
None
Page 4-3
Primary Suffix
None
Page 4-3
Parameter Name Prefix / Suffix Selections
Output Selections Beeper Volume
High
Page 4-6
Output Delays Intercharacter Delay
00 (x5mS)
Page 4-7
Interfunction Delay
00 (x5mS)
Page 4-7
Intermessage Delay
00 (x5mS)
Page 4-7
Reread Delay
Low (175mS)
Page 4-8
Good Read Delay
None
Page 4-8
Voting
Disable
Page 4-8
Code I.D. Transmit
Disable
Page 4-9
AIM I.D. Transmit
Disable
Page 4-9
Function Code Transmit
Enable
Page 4-9
Disable
Page 5-2
Data Formatter Selections Require Data Format
SCANTEAM 3700 Wedge Technical Manual
14–1
Page 82
Page 83
Page 84
14.5
Sample Bar Codes Code 39
Matrix 2 of 5
TEST–SHEET
Code 128
6543210
CODE 128
MSI [
Codabar
44332211
0013557900
Plessey [
Code 11
9876
11223344
Code 93
EAN 13
123456–9$
Code 2 of 5 9 780330 290951 123456
Interleaved 2 of 5 UPC A with 5 digit addenda 56098 1234567890
[ The default is normally for this symbology.
14–4
0 12345 67890 5
SCANTEAM 3700 Wedge Technical Manual
Page 85
A
Technical Specifications
A.1
Scanner Performance The SCANTEAM 3700 performance has been measured in terms of the first bar elongation/contraction and inner bar (space) elongation/contraction when scanning Hand Held Products test targets. If you need more information on these measurements, contact your Hand Held Products representative.
A.2
Optical Specifications Scanning Direction:
Single Line (Unidirectional)
Scan Rate:
100 scans per second. See chart below.
Scan Speeds Scans/Second 100
Approximate Lateral Scan Speed Inch/Sec mm/Sec
375
9500
Lateral Motion Sensitivity:
5 inches per second (254mm/sec)
Scan Width:
2.4 inches [61mm] at contact 3.5 inches [89mm] maximum
Focal Distance from scanner window: Focal Distance
Maximum Scan Width
1.95 inches [50mm] with a 3.5 inch [89mm] maximum scan width
MRD (minimum reflective difference):
37.5%
Tilt Angle:
Controlled by bar code length and height. (See Figure 8, on page 10-5.)
Skew Angle:
+30 to -30 degrees (See Figure 8, on page 10-5.) Specular reflection 0 to -10_ (Operation in the Specular reflection zone must be avoided.)
SCANTEAM 3700 Wedge Technical Manual
A–1
Page 86
A.3
Pitch Angle:
+7 to - 7 degrees on 7.5 mil (See Figure 8, on page 10-5.)
Light Source (Illumination):
Visible Red LED (Wavelength = 645 nm ±30)
Electrical Specifications Operating Voltage:
+5V+5% ✺
Operating Current:
250 mA, ✺
✺ Power for the SCANTEAM 3700 Wedge is provided by the host system. Communications Port Connector Pin Assignments: 1
10
10–Pin Modular Connector Communications Port
Signal
Function
Shield Not used
Shield
7
Ground TCLK TDAT VCC
System Ground Terminal Clock Terminal Data +5VDC Power (Input)
8
KDAT
Keyboard Data
9
KCLK
Keyboard Clock
Pin 1 2 3 4 5 6
10
Beeper:
A–2
The good read beeper indicator is configurable and can be disabled.
SCANTEAM 3700 Wedge Technical Manual
Page 87
A.4
Environmental Specifications Operating Temperature:
32° F to 122° F (0° C to +50° C)
Storage Temperature:
-40° F to 158° F (-40° C to +70° C)
Relative Operating and Storage Humidity:
0 to 95% (non-condensing)
Barometric Pressure:
101,000 to 69,000 Pascals (Sea level to 3000 meters)
ESD:
15 KV (A drain path for ESD should be provided when installing a 3700 in the host system.)
Shock (Drop Test):
Sustains three (3) drops from 4 feet (1.2 meters) to a non-yielding surface
Mean Time Between Failure (Ground Benign):
45,000 hrs. minimum
SCANTEAM 3700 Wedge Technical Manual
A–3
Page 88
A–4
SCANTEAM 3700 Wedge Technical Manual
Page 89
B
ASCII Conversion Table
BIT NUMBERS 0
0
0 0
0
0 1
1
0 0
1
1 1
0
1 0
0
1 1
1
1 0
1
1
COLUMN b
7 b
6 b
5 b
4 b
3 b
2 b
1
0
1
2
3
4
5
6
7
DLE
SP
0
@
P
‘ p
ROW
0
0
0
0
0
NUL
0 0
0
0
1
1
SOH DC1
!
1
A
Q a q
0
1
0
2
STX
DC2
”
2
B
R b r
0
0
1
1
3
ETX
DC3
#
3
C
S c s
0
1
0
0
4
EOT DC4
$
4
D
T d t
0
1
0
1
5
ENQ NAK
%
5
E
U e u
0
1
1
0
6
ACK SYN
&
6
F
V f v
0
1
1
1
7
BEL
ETB
’
7
G
W g w
1
0
0
0
8
BS
CAN
(
8
H
X h x
1
0
0
1
9
HT
EM
)
9
I
Y i y
1
0
1
0
10
LF
SUB
*
:
J
Z j z
1
0
1
1
11
VT
ESC
+
;
K
[ k
{
1
1
0
0
12
FF
FS
,
<
L
\ l
|
1
1
0
1
13
CR
GS
–
=
M
] m
}
1
1
1
0
14
SO
RS
.
>
N
^ n
~
1
1
1
1
15
SI
US
/
?
O
_ o
DEL
CONTROL FUNCTION DEFINITIONS NUL
Null, or all zeros
DC1
Device control 1
SOH
Start of heading
DC2
Device control 2
STX
Start of text
DC3
Device control 3
ETX
End of text
DC4
Device control 4
EOT
End of transmission
NAK
Negative acknowledge
ENQ
Enquiry
SYN
Synchronous idle
ACK
Acknowledge
ETB
End of transmission block
BEL
Bell, or alarm
CAN
Cancel
BS
Backspace
EM
End of medium
HT
Horizontal tabulation
SUB
Substitute
LF
Line Feed
ESC
Escape
VT
Vertical tabulation
FS
File separator
FF
Form feed
GS
Group separator
CR
Carriage Return
RS
Record separator
SO
Shift out
US
Unit separator
SI
Shift in
SP
Space
DLE
Data link escape
DEL
Delete
SCANTEAM 3700 Wedge Technical Manual
B–1
Page 90
B–2