Page 81

14

Default Charts

14.1

Tailoring the Terminal and Keyboard The following chart lists the factory default for the Tailoring the Terminal and Keyboard settings (indicated by a on the programming menu pages).

Default Setting

Page Reference

United States

Page 3-2

Keyboard Style

Regular

Page 3-3

Keyboard Style Modifiers

CTRL+ ASCII Mode Off

Page 3-4

Turbo Mode Off

Page 3-4

Parameter Name Country Code Selections Foreign Keyboards

Keyboard Selections

Numeric Keypad Mode Off Page 3-4

14.2

Configuring Output Parameters Defaults The following chart lists the factory default Output Parameter settings (indicated by a on the programming menu pages).

Default Setting

Page Reference

Primary Prefix

None

Page 4-3

Primary Suffix

None

Page 4-3

Parameter Name Prefix / Suffix Selections

Output Selections Beeper Volume

High

Page 4-6

Output Delays Intercharacter Delay

00 (x5mS)

Page 4-7

Interfunction Delay

00 (x5mS)

Page 4-7

Intermessage Delay

00 (x5mS)

Page 4-7

Reread Delay

Low (175mS)

Page 4-8

Good Read Delay

None

Page 4-8

Voting

Disable

Page 4-8

Code I.D. Transmit

Disable

Page 4-9

AIM I.D. Transmit

Disable

Page 4-9

Function Code Transmit

Enable

Page 4-9

Disable

Page 5-2

Data Formatter Selections Require Data Format

SCANTEAM 3700 Wedge Technical Manual

14–1

Page 82

The text of this page cannot be shown here; see it in the PDF.

Page 83

The text of this page cannot be shown here; see it in the PDF.

Page 84

14.5

Sample Bar Codes Code 39

Matrix 2 of 5

TEST–SHEET

Code 128

6543210

CODE 128

MSI [

Codabar

44332211

0013557900

Plessey [

Code 11

9876

11223344

Code 93

EAN 13

123456–9$

Code 2 of 5 9 780330 290951 123456

Interleaved 2 of 5 UPC A with 5 digit addenda 56098 1234567890

[ The default is normally for this symbology.

14–4

0 12345 67890 5

SCANTEAM 3700 Wedge Technical Manual

Page 85

A

Technical Specifications

A.1

Scanner Performance The SCANTEAM 3700 performance has been measured in terms of the first bar elongation/contraction and inner bar (space) elongation/contraction when scanning Hand Held Products test targets. If you need more information on these measurements, contact your Hand Held Products representative.

A.2

Optical Specifications Scanning Direction:

Single Line (Unidirectional)

Scan Rate:

100 scans per second. See chart below.

Scan Speeds Scans/Second 100

Approximate Lateral Scan Speed Inch/Sec mm/Sec

375

9500

Lateral Motion Sensitivity:

5 inches per second (254mm/sec)

Scan Width:

2.4 inches [61mm] at contact 3.5 inches [89mm] maximum

Focal Distance from scanner window: Focal Distance

Maximum Scan Width

1.95 inches [50mm] with a 3.5 inch [89mm] maximum scan width

MRD (minimum reflective difference):

37.5%

Tilt Angle:

Controlled by bar code length and height. (See Figure 8, on page 10-5.)

Skew Angle:

+30 to -30 degrees (See Figure 8, on page 10-5.) Specular reflection 0 to -10_ (Operation in the Specular reflection zone must be avoided.)

SCANTEAM 3700 Wedge Technical Manual

A–1

Page 86

A.3

Pitch Angle:

+7 to - 7 degrees on 7.5 mil (See Figure 8, on page 10-5.)

Light Source (Illumination):

Visible Red LED (Wavelength = 645 nm ±30)

Electrical Specifications Operating Voltage:

+5V+5% ✺

Operating Current:

250 mA, ✺

✺ Power for the SCANTEAM 3700 Wedge is provided by the host system. Communications Port Connector Pin Assignments: 1

10

10–Pin Modular Connector Communications Port

Signal

Function

Shield Not used

Shield

7

Ground TCLK TDAT VCC

System Ground Terminal Clock Terminal Data +5VDC Power (Input)

8

KDAT

Keyboard Data

9

KCLK

Keyboard Clock

Pin 1 2 3 4 5 6

10

Beeper:

A–2

The good read beeper indicator is configurable and can be disabled.

SCANTEAM 3700 Wedge Technical Manual

Page 87

A.4

Environmental Specifications Operating Temperature:

32° F to 122° F (0° C to +50° C)

Storage Temperature:

-40° F to 158° F (-40° C to +70° C)

Relative Operating and Storage Humidity:

0 to 95% (non-condensing)

Barometric Pressure:

101,000 to 69,000 Pascals (Sea level to 3000 meters)

ESD:

15 KV (A drain path for ESD should be provided when installing a 3700 in the host system.)

Shock (Drop Test):

Sustains three (3) drops from 4 feet (1.2 meters) to a non-yielding surface

Mean Time Between Failure (Ground Benign):

45,000 hrs. minimum

SCANTEAM 3700 Wedge Technical Manual

A–3

Page 88

A–4

SCANTEAM 3700 Wedge Technical Manual

Page 89

B

ASCII Conversion Table

BIT NUMBERS 0

0

0 0

0

0 1

1

0 0

1

1 1

0

1 0

0

1 1

1

1 0

1

1

COLUMN b

7 b

6 b

5 b

4 b

3 b

2 b

1

0

1

2

3

4

5

6

7

DLE

SP

0

@

P

‘ p

ROW

0

0

0

0

0

NUL

0 0

0

0

1

1

SOH DC1

!

1

A

Q a q

0

1

0

2

STX

DC2

”

2

B

R b r

0

0

1

1

3

ETX

DC3

#

3

C

S c s

0

1

0

0

4

EOT DC4

$

4

D

T d t

0

1

0

1

5

ENQ NAK

%

5

E

U e u

0

1

1

0

6

ACK SYN

&

6

F

V f v

0

1

1

1

7

BEL

ETB

’

7

G

W g w

1

0

0

0

8

BS

CAN

(

8

H

X h x

1

0

0

1

9

HT

EM

)

9

I

Y i y

1

0

1

0

10

LF

SUB

*

:

J

Z j z

1

0

1

1

11

VT

ESC

+

;

K

[ k

{

1

1

0

0

12

FF

FS

,

<

L

\ l

|

1

1

0

1

13

CR

GS

–

=

M

] m

}

1

1

1

0

14

SO

RS

.

>

N

^ n

~

1

1

1

1

15

SI

US

/

?

O

_ o

DEL

CONTROL FUNCTION DEFINITIONS NUL

Null, or all zeros

DC1

Device control 1

SOH

Start of heading

DC2

Device control 2

STX

Start of text

DC3

Device control 3

ETX

End of text

DC4

Device control 4

EOT

End of transmission

NAK

Negative acknowledge

ENQ

Enquiry

SYN

Synchronous idle

ACK

Acknowledge

ETB

End of transmission block

BEL

Bell, or alarm

CAN

Cancel

BS

Backspace

EM

End of medium

HT

Horizontal tabulation

SUB

Substitute

LF

Line Feed

ESC

Escape

VT

Vertical tabulation

FS

File separator

FF

Form feed

GS

Group separator

CR

Carriage Return

RS

Record separator

SO

Shift out

US

Unit separator

SI

Shift in

SP

Space

DLE

Data link escape

DEL

Delete

SCANTEAM 3700 Wedge Technical Manual

B–1

Page 90

B–2

SCANTEAM 3700 Wedge Technical Manual