Page 61

The text of this page cannot be shown here; see it in the PDF.

Page 62

The text of this page cannot be shown here; see it in the PDF.

Page 63

9

Supported Interface Keys 9.1

Keyboard Function Relationships The following Keyboard Function Code, HEX/ASCII Value, and Full ASCII relationships apply to all terminals that can be used with the SCANTEAM 3700 Wedge. Function Code NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

HEX/ASCII Value 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

Full ASCII + 2 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] 6 Ć

The last five characters in the Full ASCII column ( [ \ ] 6 Ć ) apply to US only. The following chart indicates the equivalents of these five characters for different countries. Country United States Belgium Scandinavia France Germany Italy Swiss United Kingdom Denmark Norway Spain

[ [ 8 ^

[ 8 8 [

\ < < 8 Ã \ < i \ \ \

Codes ] ] 9 $ + + ..

] 9 9 ]

SCANTEAM 3700 Wedge Technical Manual

6 6 6 6 6 6 6 6 6 6 6

Ć Ć Ć = Ć Ć Ć Ć Ć Ć Ć

9–1

Page 64

Supported Interface Keys Supported Interface Keys

IBM AT and PS/2 Compatibles

IBM XTs and Compatibles

NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

Reserved Enter (KP) Cap Lock Reserved Reserved Reserved Reserved CR/Enter Reserved Tab Reserved Tab Delete CR/Enter Insert Escape F11 Home Print Backspace Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

Reserved CR/Enter Caps Lock Reserved Reserved Reserved Reserved CR/Enter Reserved Tab Reserved Tab Delete CR/Enter Insert Escape Reserved Home Print Backspace Back Tab Reserved F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

* IBM 3191/92, 3471/72, 3196/97, 3476/77, DDC 3596, Telex (all models), Harris H180/190 with 122 key keyboards

9–2

SCANTEAM 3700 Wedge Technical Manual

Page 65

10

System Hardware Description

10.1

Introduction The major components of the system are the SCANTEAM 3700 Wedge and the host instrument or equipment. Electrical power is generally supplied to the 3700 Wedge by the host system. Figure 3 shows the functional relationships between the components of the basic system.

3 Disconnect

1 2

Bar Code

Scanning Circuitry ✺

Host Application

Provides Data Input

Scans Bar Code

Supplies Power to 3700 Wedge (typically)

Decoder Enables Scanning Circuitry Reads Bar Code Sends Decoded Bar Code to Host

✺ Scanning circuitry is internal to 3700 Wedge.

Figure 3. Basic System Operation

10.2

General Characteristics of the 3700 Wedge 10.2.1 Mechanical Layout of the 3700 Wedge Figure 4, on page 10-2, shows several views of the SCANTEAM 3700 Wedge, including general dimensions, the location of connectors, and the scanner window.

SCANTEAM 3700 Wedge Technical Manual

10–1

Page 66

3.5” [88.9]

Top View

2.9” [73.7]

Side View 1.05” [26.7]

Mounting Surface

Back View Interface Port (I/O Communications and Power)

Mounting Surface

Front View millimeters in brackets [mm]

Scanner Window

Figure 4. SCANTEAM 3700 Wedge Dimensions

10–2

SCANTEAM 3700 Wedge Technical Manual

Page 67

.375” [9.5]

Focal Plane 1.75” [44.5]

REF 1.95” [49.5] 2.75” [69.9]

Top View

3.5” [88.9]

Mounting Screw Location #6–32 UNC–2B or M3.5 (4 Places)

2.73” [69.3]

2.9” [73.7] .31” [7.9] ✺ Nominal Optics Center Line

1.05” [26.7]

Side View

✺ Installation should provide adjustment to align the optical center line on the intended target. This adjustment should account for tolerance variation in the 3700 Wedge scanner, as well as the host equipment. 3.1” [78.7]

.2” [5.1]

Front View

.42” [10.7]

Mounting Surface

Scanner Window millimeters in brackets [mm]

Figure 5. Mounting Dimensions for the 3700 Wedge

SCANTEAM 3700 Wedge Technical Manual

10–3

Page 68

The 3700 Wedge may be oriented in any way so the beam scanning path moves across the bar code as shown in Figure 6. Bar code presentation to the scanner is important for successful scanning of the label. The first requirement is that the beam scan path cross all bars on the label, as well a 0.25 inch quiet zone before and after the code. The Automatic Identification Manufacturers (AIM), the industry association, has defined orientation of the bar code label according to Figure 7. Bar Code Target Moving Perpendicular to Scan Beam Optical Light Center Line

Mounting Surface

Optical Light Center Line

Mounting Surface

Bar Code Target Moving Parallel to Scan Beam

Front View Indicates relative direction of bar code target movement

Mounting Surface

Figure 6. Examples of SCANTEAM 3700 Wedge Barcode Orientation

10–4

SCANTEAM 3700 Wedge Technical Manual

Page 69

PITCH OR ROLL Rotation about the Y–axis ±7°

R

SKEW OR YAW

Bar Code Label

Rotation about the X–axis ±30° (0 to –10° specular reflection interference*) *See Figure 8.

R

Bar Code Label

TILT Rotation about the Z–axis controlled by bar code length and height R

Bar Code Label

Rear View R = Rotation THE ABOVE DEFINITIONS ARE FROM AIM SPECIFICATIONS

Figure 7. SCANTEAM 3700 Wedge Pitch, Skew and Tilt Tolerance

–30°

Mounting Surface

–10° Bar Code Target

0°

.31” [7.9]

ÇÇÇÇÇÇÇ

Nominal Optics Center Line

SCANTEAM 3700 Wedge +30°

Specular Zone (Operation in the Specular Zone must be avoided.)

Figure 8. Specular Reflection Interference

SCANTEAM 3700 Wedge Technical Manual

10–5

Page 70

– NOM – Focal Plane

1.55” [39.4]

15° 27° 2.4” [61]

3.5” 3.1” [88.9] [78.7]

Top View clearance required for = Minimum scanner illumination of target. [

= Receive path/area. [ .61” [15.5] .2” [5.1]

2°

Side View 2°

[ Illumination area is larger than receive area.

millimeters in brackets [mm]

Figure 9. Scanner Illumination Clearance

10.2.2 Single Modular Input / Output / Power Port The interface port is an 8-pin female modular connector used for attaching the keyboard wedge cable. Power and ground connections are also on this port.

10–6