The text of a manual · part 5 of 10
SCANTEAM 3700 Wedge Technical Manual, pages 41 to 50
Pages 41 to 50 of 100
The original document is the PDF (648 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP ST3700
Page 41
Full ASCII The Code 39 specification provides a means of encoding the full ASCII set of characters by using twoĆcharacter sequences made up of one of the four Code 39 characters ($ + % /) followed by one of the 26 letters as shown in the Full ASCII Code 39 chart (on page 6-9). The 3700 Wedge can't distinguish Code 39 labels encoded in full ASCII mode from those encoded in standard mode. Set this decoder option according to the mode used when the symbols were printed. Default = Enable.
Full ASCII ✱ Enable
Disable
Append When the append option is enabled, the reader will identify Code 39 messages whose leading character is a SPACE, as Append39 symbols. The leading SPACE is discarded and the remaining message characters are stored in a buffer. When a non-Append39 symbol is scanned, all data is transmitted in the order it was scanned. Default = Disable.
Append ✱ Disable
Enable
Decoding The 3700 Wedge uses industry standard decoding algorithms to ensure data integrity. Adaptive decoding employs a more aggressive decoding algorithm that is more tolerant when bar code symbols do not conform to the symbology specifications and that results in scanning. Default = Adaptive.
Decoding ✱ Adaptive
Traditional
Programming Tip: If a symbology won't be used, we recommend turning it off to minimize the chance of a misread.
SCANTEAM 3700 Wedge Technical Manual
6–7
Page 42
Message Length We recommend setting the minimum and maximum message lengths according to the smallest range [Minimum, Maximum] the application allows. The start/stop, check characters should not be counted as message characters. For a fixedĆlength message Minimum Length=Maximum Length. This will also help minimize the chance of a misread. Defaults on default chart at the end of this manual. Note: To select digits 0 through 9 use the Programming Chart found on the inside of the back cover of this menu. Scan the programming selection bar code first, and then scan the bar code(s) representing the digits you wish to set.
Message Length Minimum ]
Maximum ]
Check Character Use of a check character is optional in Code 39. For applications requiring enhanced security, symbols should be printed with a check character using the format described in the AIM specification, and the reader should be programmed to verify its value. Since it is not considered part of the message the check character is not ordinarily transmitted, though the reader can be programmed to transmit it. Default = No Check Character.
✱ No Check Character
Validate, But Don't Transmit
Validate, And Transmit
Programming Tip: If a symbology won't be used, we recommend turning it off to minimize the chance of a misread.
6–8
SCANTEAM 3700 Wedge Technical Manual
Page 43
Page 44
6.2.3
Code 93
Default All Code 93 Settings Scanning the Default bar code will program the 3700 Wedge to the symbology options indicated by a in the menu selections on this programming page.
✱ Default All Code 93 Settings ✱
Code 93 Code 93 was designed to drop into applications that use Code 39. It is a continuous, edgeĆtoĆedge symbology capable of encoding variableĆlength messages from the set of alphanumerics, and 12 additional characters. Each Code 93 character is nine modules wide, and is comprised of 3 bars and 3 spaces. Its characters are spatially efficient for the set of alphanumerics. Code 93 can be used to represent all 128 ASCII characters in a fashion similar to Code 39's Full ASCII mode; however, Code 93's special shift characters distinguish full-ASCII combinations from the standard alphanumeric set. There is no need to enable full-ASCII decoding. The Code 93 specification requires the use of two check characters; the symbology is highly secure. Character: Start
Stop
Termination Bar
Code 93 123456-9$
Check Characters
Code 93 ✱ On
Off
Message Length We recommend setting the minimum and maximum message lengths according to the smallest range [Minimum, Maximum] the application allows. The start/stop and check characters should not be counted. This will also help minimize the chance of a misread. Defaults on default chart at the end of this manual. Note: To select digits 0 through 9 use the Programming Chart found on the inside of the back cover of this menu. Scan the programming selection bar code first, and then scan the bar code(s) representing the digits you wish to set.
Message Length Minimum ]
Maximum ]
Programming Tip: If a symbology won't be used, we recommend turning it off to minimize the chance of a misread.
6–10
SCANTEAM 3700 Wedge Technical Manual
Page 45
Page 46
Message Length If the application requires the ability to read variableĆlength messages, or some other fixedĆlength, then choose the minimum and Maximums accordingly. We recommend setting the range [Minimum, Maximum] as small as the application allows. Defaults on default chart at the end of this manual. Note: To select digits 0 through 9 use the Programming Chart found on the inside of the back cover of this menu. Scan the programming selection bar code first, and then scan the bar code(s) representing the digits you wish to set. Bearer bars having a width comparable to the wide elements can be printed to further enhance security.
Interleaved 2 of 5
Bearer Bars 123456
Message Length Minimum ]
Maximum ]
Check Digit Use of a check digit is optional in Interleaved 2 of 5. For applications requiring enhanced security, symbols should be printed with a check digit using the format described in the AIM specification, and the reader should be programmed to verify its value. Since it is not considered part of the message the check digit is not ordinarily transmitted, though the reader can be programmed to transmit it. Default = No Check Digit. Programming Tip: If a symbology won't be used, we recommend turning it off to minimize the chance of a misread.
✱ No Check Digit
Validate, But Don't Transmit
Validate, And Transmit
] A twoĆdigit number is required after scanning this programming bar code. Please scan your selection on the Programming Chart (inside back cover).
Programming Tip: If a symbology won't be used, we recommend turning it off to minimize the chance of a misread.
6–12
SCANTEAM 3700 Wedge Technical Manual
Page 47
Page 48
Page 49
6.2.7
Code 11 and Code 128
Default All Code 11 / Code 128 Settings Scanning the Default bar code will program the 3700 Wedge to the symbology options indicated by a in the menu selections on this programming page.
✱ Default All Code 11 / Code 128 Settings ✱
Code 11 Code 11 is a discrete code capable of encoding variableĆlength messages from the set of numerics plus the character. The symbology derived its name from the size of its character set. Each character in Code 11 has three bars and two internal spaces: two of these elements are wide, the other three are narrow. The exceptions to this are the and characters, which have one extraĆwide element and four narrow elements. Code 11 can be decoded as a twoĆwidth symbology, though the bars can assume one of three widths. Default = On.
Code 11 ✱ On
Off
Check Digits Required The Code 11 specification strongly recommends the use of two check digits. The decoder can be programmed to read Code 11 symbols having only one check digit. Bar code readers cannot autodiscriminate the number of check digits encoded in a symbol. Default = 2 Check Digits. With 2 Check Digits
With 1 Check Digit
123456 11
1234567890 1
Code 11
Check Digits Required ✱ 2 Check Digits
1 Check Digit
Message Length Minimum ]
Maximum ]
] A twoĆdigit number is required after scanning this programming bar code. Please scan your selection on the Programming Chart (inside back cover). Programming Tip: If a symbology won't be used, we recommend turning it off to minimize the chance of a misread.
SCANTEAM 3700 Wedge Technical Manual
6–15