The text of a manual · part 1 of 10

SCANTEAM 3700 Wedge Technical Manual, pages 1 to 10

Pages 1 to 10 of 100

The original document is the PDF (648 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the HHP ST3700

Page 1 read from a scan by OCR; it may hold reading errors

WANS HELE a WelchAllyn’ affiliate

SCANTEAM 3700 Wedge

Technical Manual

Page 2

This Technical Manual is used to operate and program the SCANTEAM 3700 Wedge. Special Pages A Sample Bar Codes page (located on page 14-4) contains bar code symbols you may scan to verify that your scanner has been programmed correctly. Charts listing the factory default selections are included on the pages just before the Sample Bar Codes. On the programming menu pages, default selections are indicated by a next to the bar code title. A Bar Code Data Chart (found on the inside back cover of this manual) contains alphanumeric bar codes for setting additional programming options, such as the digits representing Symbology Message Length. The information on the menu pages explains how to use this chart.

Disclaimer

Welch Allyn, Data Collection, Inc. (d/b/a Hand Held Products) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult Hand Held Products to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of Hand Held Products. Hand Held Products shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material. This document contains proprietary information which is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of Hand Held Products. E2000 Welch Allyn Data Collection, Inc. All rights reserved. Web Address: www.handheld.com

Page 3

Statement of Agency Compliance This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

FCC Class B Compliance Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • • • •

Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio or television technician for help.

Caution: Any changes or modifications made to this device that are not expressly approved by Welch Allyn, Inc. may void the user’s authority to operate the equipment. Note: To maintain compliance with FCC Rules and Regulations, cables connected to this device must be shielded cables, in which the cable shield wire(s) have been grounded (tied) to the connector shell.

Canadian Notice This equipment does not exceed the Class B limits for radio noise emissions as described in the Radio Interference Regulations of the Canadian Department of Communications. Le present appareil numerique n’emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la classe B prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Communications du Canada.

Page 4

The CE mark on the product indicates that the system has been tested to and conforms with the provisions noted within the 89/336/EEC Electromagnetic Compatibility Directive and the 73/23/EEC Low Voltage Directive. For further information, please contact: Welch Allyn Ltd. 1st Floor Dallam Court Dallam Lane Warrington, Cheshire WA2 7LT England Welch Allyn shall not be liable for use of our product with equipment (i.e., power supplies, personal computers, etc.) that is not CE marked and does not comply with the Low Voltage Directive.

Patents The SCANTEAM 3700 Wedge product is covered by the following U.S. Patent: 5,932,862. Other U.S. and foreign patents pending.

Page 5

TABLE OF CONTENTS

Disclaimer Agency Compliance SCANTEAM 3700 Wedge Description Section

1.1 1.2 1.2.1 1.2.2 1.3 1.5

Page

SCANTEAM 3700 Wedge Description . . . . . . . . . . . . . . . . . . . Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interface Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Nonvolatile Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Software Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3700 Wedge Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1–1 1–2 1–2 1–2 1–2 1–3

Getting Started Section

2.1 2.2 2.3 2.4

Page

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connecting to a PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Terminal Selection Programming Instructions . . . . . . . . . . . . . Quick Suffix Selections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2–1 2–2 2–3 2–4

Tailoring the Terminal and Keyboard Section

3.1 3.2 3.3 3.4

Page

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Country Code Selections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Keyboard Style Selections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Keyboard Style Modifiers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3–1 3–2 3–3 3–4

Configuring the Output Parameters Section

4.1 4.2 4.2.1 4.3

Page

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Prefix/Suffix Selections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Prefix and Suffix Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Output Selections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4–1 4–2 4–4 4–6

Formatting the Data Message Section

5.1 5.1

Page

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Data Formatter Selections . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5–1 5–2 i

Page 6

Symbology Menu Section

6.1 6.2 6.2.1 6.2.2 6.2.3 6.2.4 6.2.5 6.2.6 6.2.7 6.3 6.3.1 6.3.2 6.3.3 6.3.4 6.3.5

Page

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Industrial Symbology Selections . . . . . . . . . . . . . . . . . . . . . . . . Codabar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code 39 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code 93 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Interleaved 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Matrix 2 of 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Code 11 and Code 128 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Retail Symbology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EAN (European Article Numbering) Settings . . . . . . . . . . . . . . UPC (Universal Product Code) Settings . . . . . . . . . . . . . . . . . EAN / UPC Addenda . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MSI Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Plessey Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6–1 6–3 6–3 6–6 6–10 6–11 6–13 6–14 6–15 6–17 6–17 6–19 6–21 6–23 6–24

Factory Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7–1 Firmware Utility Menu Section

8.1 8.1.1 8.1.2 8.1.3

Page

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Downloading Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Uploading Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Temporary Serial Communication Configuration . . . . . . . . . .

8–1 8–2 8–2 8–2

Supported Interface Keys Section

9.1

Page

Keyboard Function Relationships . . . . . . . . . . . . . . . . . . . . . . .

9–1

System Hardware Description Section

10.1 10.2 10.2.1 10.2.2 10.2.3 10.2.4 10.3

Page

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General Characteristics of the 3700 Wedge . . . . . . . . . . . . . . Mechanical Layout of the 3700 Wedge . . . . . . . . . . . . . . . . . . Single Modular Input / Output/ Power Port . . . . . . . . . . . . . . . . Audible Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mounting Inserts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operating Theory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10–1 10–1 10–1 10–6 10–7 10–7 10–7

Troubleshooting And Maintenance Section

11.1

Page

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11–1

Customer Support Section

12.1 12.2 ii

Page

Obtaining Factory Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Help Desk . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

12–1 12–2

Page 7

Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13–1 Default Charts Section

14.1 14.2 14.3 14.4 14.5

Page

Interface Menu Defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General Operating Menu Defaults . . . . . . . . . . . . . . . . . . . . . . . Symbology Menu Defaults - Industrial . . . . . . . . . . . . . . . . . . . Symbology Menu Defaults - Retail . . . . . . . . . . . . . . . . . . . . . . Sample Bar Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14–1 14–1 14–2 14–3 14–4

Appendix A – Technical Specifications Section

A.1 A.2 A.3 A.4

Page

Scanner Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Optical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Environmental Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . .

A–1 A–1 A–2 A–3

Appendix B – ASCII Conversion Table . . . . . . . . . . . . . . . . B–1 Glossary Figures Number

Page

Figure 1. Symbology Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 2. Hex to ASCII Conversion Chart . . . . . . . . . . . . . . . . . . . . . . . . Figure 3. Basic System Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 4. SCANTEAM 3700 Wedge Dimensions . . . . . . . . . . . . . . . . . Figure 5. Mounting Dimensions for the 3700 Wedge . . . . . . . . . . . . . . Figure 6. Examples of SCANTEAM 3700 Wedge Bar Code Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 7. SCANTEAM 3700 Wedge Pitch, Skew and Tilt Tolerance Figure 8. Specular Reflection Interference . . . . . . . . . . . . . . . . . . . . . . . Figure 9. Scanner Illumination Clearance . . . . . . . . . . . . . . . . . . . . . . . Figure 10. Basic Scanner/Decoder Operation . . . . . . . . . . . . . . . . . . . .

4–5 4–5 9–1 9–2 9–3 9–4 9–5 9–5 9–6 9–7 iii

Page 8

iv

Page 9

SCANTEAM 3700 Wedge Description

1.1

1

Introduction This chapter explains the SCANTEAM 3700 Wedge setup for use in the design lab and a brief description of installation in a host instrument. The setup procedures are intended for a technician or design engineer to explore the functions and features of the 3700 Wedge in a hands–on setting, before the 3700 Wedge is embedded in host equipment. The System Hardware Description section includes the general mounting dimensions of the 3700 Wedge. Setup and installation includes unpacking the unit, checking for possible damage during shipment, and connecting the Machine Mount CCD to the host system. The host system will typically be a PC/DOS computer with an external keyboard. The Hand Held Products SCANTEAM 3700 Wedge is a fixed mount CCD bar code scanner with integral decoder for easy integration into host equipment. Typical host equipment with bar code requirements satisfied by the 3700 Wedge include automated clinical chemistry analyzers, pharmaceutical label verification systems, industrial automation equipment, robotic systems, materials handling equipment, library systems, point of sale terminals and office equipment. The 3700 Wedge features Hand Held Products’ time proven decoding algorithms in a microprocessor controlled bar code scanner/decoder and offers configurable operating parameters, providing you with the capability to tailor the 3700 Wedge to your present requirements and the flexibility to meet your future application requirements. The following features are available with every SCANTEAM 3700 Wedge: • • • • •

Economical, reliable, safe CCD scanning technology Autodiscrimination of 12 bar code symbologies 100 scans per second Decoder configurable for high security Scan voting to ensure bar code data integrity

SCANTEAM 3700 Wedge Technical Manual

1–1

Page 10

1.2

SCANTEAM 3700 Wedge Hardware Description The SCANTEAM 3700 Wedge housing is molded ABS formed to enclose the optics platform and electronics. Housing width is 3.5 inches (88.9mm). The housing length is 2.9 inches (73.7mm) and the height is fixed at 1.05 inches (26.7mm). The scanner uses red (660 nm wavelength) LED’s to illuminate the bar code label. A CCD (charge coupled device) is used as an image or reading sensor. The scanned code is converted to a digital signal in the scanner, then decoded and sent to the host computer or system. 1.2.1

Interface Port

The SCANTEAM 3700 Wedge has one port for I/O and Power. The port is a 10 pin RJ11 modular female connector. Cables are available from Hand Held Products for evaluation of the 3700 Wedge. A modular connector was chosen as the standard configuration for ease in servicing the scanner once installed. 1.2.2

Nonvolatile Memory

The 3700 Wedge contains nonvolatile FLASH memory which is used to store operating parameters configured by means of bar code menu.

1.3

SCANTEAM 3700 Wedge Software Description SCANTEAM 3700 Wedge software employs Hand Held Products’ time proven decoding algorithms, controls the microprocessor functions, decodes the bar codes, and formats the output messages. The 3700 Wedge standard default parameters can be easily reconfigured to meet most scanning requirements. Application specific features and options are configurable through menus. The 3700 Wedge can be configured to autodiscriminate among the following bar code symbologies and their variations: Codabar, Code 39, Code 93, Code 128, Code 2 or 5, Matrix 2 of 5, Code 11, Interleaved 2 of 5, UPC, EAN, EAN/UPC Addenda, MSI, and Plessey. Most common bar code options, such as validating symbol length and optional check character, are supported and easily selected. In addition to decoding selections; data output formats, such as prefix and suffix strings, and operating parameters are also configurable.

1–2

SCANTEAM 3700 Wedge Technical Manual