Page 81

SCANTEAM 3400PDF Options: –X2X (TTL), and –X3X (TRUE) Decoded Out Connector Pin Assignments: The Scanner provides decoded output data format. See chart below. 1

10–Pin RJ41 Modular Connector

Pin

Standard Welch Allyn Color Code

Braid Blue Black Orange

N/C N/C Prog 1 Ground RXD

6

Green

TXD

7 8

Red White

+5VDC RTS

9 10

Gray

CTS N/C

A–4

Function

Signal

1 2 3 4 5

10

Cord Shield Supply Ground Receive Data – Serial Data to Scanner Transmit Data – Serial Data from Scanner 5 Volt Power Connection Request to Send Data Clear to Send Data

Technical Specifications

Page 82

SCANTEAM 3400PDF Options: –X2X (TTL), and –X3X (TRUE) continued

1

5

6

9

9–Pin D Shell Connector

Pin

Standard Welch Allyn Color Code

Signal

1

Blue

Prog 1

2

Green

TXD

3

Orange

RXD

4

Function

Transmit Data – Serial Data from Scanner Receive Data – Serial Data to Scanner

N/C

5

Black

Ground

Supply Ground

6 7

Gray

N/C CTS

Clear to Send Data

8

White

RTS

Request to Send Data

9

Red

+5VDC

5 Volt Power Connection

Technical Specifications

A–5

Page 83

A.4 Environmental Specifications Operating Temperature:

32° F to 122° F (0° C to 50° C)

Storage Temperature:

–40° F to 158° F (–40° C to 70° C)

Relative Operating and Storage Humidity:

0 to 95% (non–condensing)

Barometric Pressure:

101,000 to 69,000 Pascals (Sea level to 3400 meters)

Shock:

Sustains 5 foot drop to a non–yielding surface

ESD:

15 KV

Ambient Illumination:

3400 Lux

Mean Time Between Failure (Ground Benign):

74,000 hrs.

Note:

The SCANTEAM 3400PDF scanner stores configuration parameters in flash memory. Saving configuration parameters more than 1000 times exceeds the specifications of the flash memory.

A.5 Mechanical Specifications

A–6

Weight:

8.5 ounces without cord

Interface Cable:

8 foot coiled cord (Refer to Figure A–2)

Cord Flexure:

Cord–scanner strain relief withstands in excess of 1,000,000 flexures of +90 degree flexure while stressed with a weight of 6.7 ounces.

Interface Connector:

Standard Connector – 9–Pin D Shell

Technical Specifications

Page 84

9.5±.5

Extended 65.0±.6 [1651.0±152.4] Retracted 8.0±.5 [203.2±12.7]

Warning Label

7.0±1.0

Reference Label 18.0±2.0

9 pin D Female with external power 9 pin D Male with external power

Dimensions are in inches [mm]

Figure A.2 Dimensional Figure of 8’ Coiled Cord

A.6 Regulatory and Safety Requirements FCC Class B Canadian Ministry of Communications CE Mark

A.7 Patents Patents Pending

Technical Specifications

A–7

Page 85

A.8 Bar Code Symbol Specifications All bar code symbols should satisfy the appropriate AIM Uniform Symbology Specification. Background Substrate The bar code symbol should be printed on material which is reflective and has a matte (not glossy) finish. A background diffuse reflectance of at least 70% to 80% is desirable for optimum contrast. Ink Color and Type The type of ink should be compatible with 660nm LEDs used in the scanner. The bar code symbols inked bars should not exceed 10% reflectance at 660nm which is being used for reading, whether printed with black ink or colored ink. Voids and Specks The code should be printed clearly, free of voids, specks, blemishes and lines which could “fool” the scanner. Specks or blemishes in the white spaces, or false or missing bar sections could be interpreted by the reading equipment as part of the code. Generally, the width of such flaws is more serious than the height. Code symbols should be rejected if these defects are present. Definition The bars in the bar code symbol should be well defined. Their edges should not be rough or fuzzy, so that the bars and spaces have the proper widths intended for the bar code symbology used. Since a scanner’s aperture and resolution are chosen to comply with these widths, definition should be sharp and consistent. Tolerance The ratio of the widths of bars and spaces in a bar code symbol must conform to the appropriate AIM bar code specifications and can cause problems if not correct throughout the bar code. Problems can occur when bar edges are smeared or rough, or when they exhibit voids.

A–8

Technical Specifications

Page 86 read from a scan by OCR; it may hold reading errors

INDEX

A

AIM Publications, vi Auto - Trigger Mode, 3 - 5

B

Bar Code Chart, 4 - 4

Bar Code Symbol Specifications, A-8 Background Substrate, A - 8 Definition, A - 8 Ink Color and Type, A - 8 Tolerance, A - 8 Voids and Specks, A - 8

Bar Code Symbologies, Supported Symbologies, 1 - 4

Bar Code Symbology, 1 - 4 Bar Code Test Symbol, 3 - 6 Beeper, 4 - 2

Beeper Attributes

Beep on Good Read, 4 - 8

Beep on Power Up, 4 - 7

PDF417: Humming Indicates Decoder Busy, 4 - 8

PDF417: Ticking Indicates Scanning Progress, 4 - 8

Volume, 4 - 7

Beeper Feedback, 4 - 8 Double Beep, 4 - 8 Humming, 4 - 8

Single Beep, 4 - 8 Ticking, 4 - 8 Triple Beep, 4 - 8

D

Data Collection, 4-3

Decoded Output Scanner, Programming Menu, Retail Codes, 4-23

Decoding, 4 - 3

E

Electrical Specifications, A - 3 Operating Current Auto - Trigger Mode, A - 3 Manual Trigger Mode, Low Power, A - 3 Operating Voltage, A - 3 Power Supply Noise Rejection, A-3 Environmental Specifications, A-6 Ambient Illumination, A - 6 Barometric Pressure, A - 6 ESD, A - 6 Humidity, A - 6 Mean Time Between Failure, A-6 Operating Temperature, A - 6 Shock, A - 6 Storage Temperature, A - 6

Page 87 read from a scan by OCR; it may hold reading errors

F

Factory Service, 6 - 4 Out of Warranty, 6 - 4 Under Warranty, 6 - 4

G

Good Read, 4-3

H

Hardware Components, 2 - 3 CCD Sensor, 2 - 4 LED, 2 - 4 Microprocessor, 2 - 5 Peak Detectors and Comparator, 2 - 5

Hardware Summary, 1 - 5

HEX- - ASCT Chart, 4 - 15

Identification Label, 3 - 2 Industrial Symbologies, 4 - 21

Interface Cable Replacement, 3-4

Interface Cord, 3-3

L

Label readability, 5 - 3

M

Maintenance, 6 - 1 Cleaning the Scan Window, 6-1 Inspecting the Scanner, 6 - 2 Cords and Cables, 6 - 2 Interface Cable Replacement, 6-2

Manual and Automatic Trigger, 3-4

Manual Scan Mode, 3 - 5

Mechanical Specifications, A - 6 Cord Flexure, A - 6 Interface Cable, A - 6 Interface Connector, A - 6 Weight, A - 6

Model Identification, 3 - 2 Focal Distance, 3 - 2 Interface Option, 3 - 2 Scan Rate, 3-2 Trigger Option, 3 - 2

Model Number. See Identification

Label

N

Non- - Volatile Memory, 1 - 5

Page 88 read from a scan by OCR; it may hold reading errors

O

Optical Specifications, A - 1 Light Source, A - 1 Maximum Bar Code Width,

A-1 Pitch Angle, A - 1 Pitch/Roll, A - 2 Read Starting Method, A - 1 Reading Sensor, A - 1 Scan Rate, A - 1 Scanning Direction, A - 1 Skew Angle, A - 1 Skew/Yaw, A - 2 p

Patents, A - 7

PDF417, 1-4

PDF417 Damage Tolerance, 5 - 4 PDF417 Error Correction, 5 - 2 PDF417 Parameters, 5 - 1 PDF417 Scan Speed, 5 - 3 PDF417 Tilt Angle, 5 - 3

Printing PDF17 Labels, 5 - 1 Product Accessories, 1 - 7

Programmable Option Summary,

Programming Guide, Wand Emulation, 4 - 11

Characters per Data Block, 4 - 11

Delay Between Data Blocks, 4 - 11

Digital Output Signal Polarity, 4 - 11

Output Scan Rate, 4-11

Overall Checksum, 4-11

Programming Menu, 4 - 4 Beeper Attributes, 4 - 7 Code Selection, 4 - 7 Disable All Symbologies, 4 - 28 Hex - ASCII Chart, 4-15 Industrial Symbologies, 4 - 21 Longitudinal Redundancy Checking, 4 - 17 LRC Menuing Options, 4 - 17 Menu Selections, 4 - 6 Prefix/Suffix, 4-14 Prefix/Suffix Programming, 4 - 7 Recommended Programming Sequence, 4 - 7 Retail Symbologies, 4 - 23 RS - 232 Parameters, 4 - 7 RS - 232 Serial Output, 4 - 9 Baud Rate, 4 - -9 Character Format, 4 - 9 Data Flow Control, 4-9 No Read Notification, 4 - 11 Serial Menu, 4 - 7, 4 - 28 Stacked Codes, PDF417, 4 - 26 Symbology Chart, 4 - 16 Trigger Options, 4 - 7, 4 - 13 Autotrigger Enable, 4 - 13 Manual Trigger Enable, 4 - 13 Wand Emulation, 4 - 7

Programming Menu Selections,

4 - 2 Beeper, 4 - 2 Code Selection, 4 - 2 Disable All Symbologies, 4 - 2 Prefix/Suffix, 4 - 2 RS - 232 Output, 4-2 Serial Menu, 4 - 2 Trigger Mode, 4 - 2

R

Reader Identification, 3 - 1

Reader Programming

Conventions, 4 - 1

Page 89

Reading Conventional Codes, 2-1 Reading PDF417 Codes, 2-1

Ireland, 6-4 U.K., 6-4 U.S., 6-4

Regulatory and Safety Requirements, A-7

Set-Up and Installation, 3-3

Related Publications, vi

Symbology Chart, 4-16

Replacement/Alternate Interface Cables, 1-7 Retail Symbologies, 4-24 RTS/CTS Handshaking, 4-10

Special Characters, 4-16

Technical Specifications, A-1 Timing Sequence, 2-5

Troubleshooting, 6-3 Troubleshooting Guide, 6-3

Scanner Holder, 1-7 Scanner Performance, A-1 Scanner Signals, 4-3 Audio Feedback, 4-3 PDF417 Decoding, 4-3 Scanning Bar Codes, 3-6 SCANTEAM 3400PDF, Model Identification, 3-2 SCANTEAM 3400PDF Configurations, 1-3 Serial Number. Identification Label Service Hong Kong, 6-5

Welch Allyn Product Service Asia, 6-5 Europe and Great Britain, 6-4

Unpacking the Scanner, 3-1

XON/XOFF Protocol, 4-10

Page 90

This page is a scan with no text; see it in the PDF.