The text of a manual · part 6 of 10
SCANTEAM 3400PDF PDF417 Capable CCD Reader Technical Manual, pages 51 to 60
Pages 51 to 60 of 91
The original document is the PDF (400 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the HHP ST3400
Page 51
Example Application #1
!'+,
+ "+ +,*"& %-+, '& !'+, (*' "+ '& (*' "& -*'
STX
Bar Code Message
Prefix
LRC,ETX
Suffix
& ,!"+ ,'
Programming Flow
1.
Enter Prefix/Suffix programming.
2.
Select Prefix programming.
3.
Set the LRC to the value of the required (HEX value) suffix. (87XX) (This includes the suffix in the LRC calculations.)
4.
Scan the required prefix as a HEX value.
5.
Select Suffix programming.
6.
Scan 86 to transmit the LRC to transmit as one character.
7.
Scan the required suffix as a HEX value.
8.
Exit Prefix/Suffix programming.
Programming Steps
4–18
1.
Scan the Enter label on the Prefix/Suffix menu page.
2.
On Bar Code Chart I, scan Roman Numeral I. Programming the Reader
Page 52
3.
On Bar Code Chart III, scan
8 7 0 3
4.
On Bar Code Chart III, scan 02
5.
On Bar Code Chart I, scan Roman Numeral II.
6.
On Bar Code Chart III, scan 86.
7.
On Bar Code Chart III, scan 03.
8.
Scan the Exit label.
-!"" %)* !* !) * $% * -!"" * *-% %( * - ) *
Example Application #2
Remaining Prefix Characters
Bar Code Message
Prefix
LRC,CR,ETX
Suffix
* after * * $%* !$ * * * * * *% * * !$ *
-
*% Programming the Reader
4–19
Page 53
-
Programming Flow
1.
Enter Prefix/Suffix programming.
2.
Select Prefix programming.
3.
Set the LRC value to the computed X’ored (Hex) value (87XX)
4.
Scan the required prefix as a Hex value.
5.
Select Suffix programming.
6.
Scan 86 to transmit the LRC to transmit as one character.
7.
Scan the required suffixes as Hex values.
8.
Exit Prefix/Suffix programming mode.
Programming Steps
4–20
1.
Scan the Enter label on the Prefix/Suffix menu page.
2.
On Bar Code Chart I, scan Roman Numeral I.
3.
On Bar Code Chart III, scan
4.
On Bar Code Chart III, scan 02
5.
On Bar Code Chart I, scan Roman Numeral II.
6.
On Bar Code Chart III, scan 86.
8 7 0 E
Programming the Reader
Page 54
7.
On Bar Code Chart III, scan
8.
Scan the Exit label.
0 D 0 3
4.6.7 Code Selection I (Industrial) Menu Page The SCANTEAM 3400PDF autodiscriminates between the following Industrial symbologies: Codabar, Code 39, Interleaved 2 of 5, and Code 128. The Code Selection I (Industrial) page of the SCANTEAM PDF417 Programming Menu is used to disable or enable all Industrial symbologies. When a symbology is disabled, the unit ignores any scans of that particular symbology. No error signal (beep) is issued. Available Industrial codes and their options are listed in Table 4.6. Minimum and Maximum lengths are selectable for all Industrial symbologies. Table 4.6 Industrial Symbologies Length Symbology Min Max
Options
Codabar
01
60
Start/stop transmit, check character transmission, concatenation
Code 39
00
48
Start/Stop transmit, check character transmission, full ASCII, symbol appendation
I 2 of 5
02
80
Check digit, check digit (even #’s only) transmission
Code 128
01
80
None
Programming the Reader
4–21
Page 55
Example: Configure the SCANTEAM 3400PDF to decode the following symbologies:
Code 39:
Minimum Length = 8 Maximum Length = 14 Start/Stop: Transmit Check Digit: Required Check Digit: Transmit Full ASCII: Yes
Code 128:
Minimum Length = 6 Maximum Length = 12
Refer to the Selections/Variables options on the CODE Selection I (Industrial) page of the SCANTEAM PDF417 Programming Menu. Note:
If Check Digit is required and the code does not contain a check digit, the SCANTEAM 3400PDF will not read the code.
The scanning sequence to program the scanner to read these Code 39 and Code 128 formats would be: FUNCTION
SELECTION
Enter Menu Page ENTER Set DEFAULT Values DEFAULT Set Code 39 II Set Start/Stop Characters To Transmit Set Check Char Required To Required Set Check Digit To Transmit Set Full ASCII To enabled Set Minimum Length To 8 Set Maximum Length To 14 Scanning sequence continued on next page. 4–22
Programming the Reader
VARIABLE
A Yes B Yes C Yes D Yes F 0 8 G 1 4
Page 56
FUNCTION
SELECTION
Set Code 128 To enabled Set Minimum Length To 6
IV Yes A 0 6 B 1 2
Set Maximum Length To 12 Leave Menu Page Note:
VARIABLE
EXIT
To maximize reading efficiency and security, all unused codes should be disabled.
Code 39 may have the “append” function enabled or disabled with the programming menu, whereas the Code 128 “append” function cannot. Note:
If you try this example, the reader will be left operating with these parameters. To return the reader to the default parameters settings, scan
ENTER DEFAULT EXIT 4.6.8
Code Selection II (Retail) Menu Page
The SCANTEAM 3400PDF autodiscriminates between the following Retail symbologies: UPC, EAN. The Code Selection II (Retail) page of the SCANTEAM PDF417 Programming Menu is used to disable or enable all Retail symbologies. When a symbology is disabled, the unit ignores any scans of that particular symbology, and no error signal (beep) is issued. Available Retail symbologies and their options are listed in Table 4.7.
Programming the Reader
4–23
Page 57
Table 4.7 Retail Symbologies Length Symbology Min Max
Options
UPC
Not Selectable
Enable Version (A, E), Version E output compressed or expanded, 2 or 5 digit addendum, check digit transmission, number system digit transmission.
EAN/JAN
Not Selectable
Enable Version 8 and 13, 2 or 5 digit addendum, check digit transmission ISBN conversion.
UPC & EAN
Addenda Required Yes or No
A symbology with an incorrect check character is ignored, that is; it is treated as a disabled symbology. The check character for all applicable symbologies may be transmitted or not, depending on the menu selection made. UPC Version E may be transmitted as an expanded symbology (with zeros inserted) or in its compressed state as shown in the human readable interpretation. For example, consider the decoded UPC–E data message 078349. The number system digit and check digit transmissions are disabled. When the “compressed” option is enabled, data will be transmitted as 078349. If the “expanded” option (Version E Expand) is enabled, the same data message will be transmitted as 0783400009. In order to assure highest reading accuracy, all unused symbologies which do not default to the disabled state should be disabled.
4–24
Programming the Reader
Page 58
Example: Configure the SCANTEAM 3400PDF to the following retail code symbologies and values:
UPC–A will be sent with the following properties: Check Digit Xmit Disabled # System Digit Disabled Read UPC Version E (expanded) 2-digit Addenda Disabled 5-digit Addenda Disabled Refer to the Selections/Variables table on the CODE Selection II (Retail) page of the SCANTEAM PDF417 Programming Menu. The scanning sequence to program the scanner to read only this UPC Code format would be: FUNCTION
SELECTION
Enter Menu Page Set DEFAULT Values Enable UPC–A
ENTER DEFAULT I
Enable UPC Version E 0 Enable UPC Version E 1 Disable Check Digit Xmit Disable # System Xmit Enable UPC–E Expanded Disable 2-digit Addenda Disable 5-digit Addenda Disable EAN Disable EAN/JAN 13
VARIABLE
A Yes C Yes D Yes E No F No G Yes H No I No
II A No
Scanning sequence continued on next page. Programming the Reader
4–25
Page 59
FUNCTION
SELECTION
Disable EAN/JAN 8 Disable UPC & EAN Addenda Required Leave Menu Page
VARIABLE
B No III No EXIT
Note:
To assure highest reading accuracy, all unused symbologies (EAN/JAN13, EAN/JAN 8) were disabled.
Note:
If you try this example, the reader will be left operating with these parameters. To return the reader to the default parameters settings, scan FUNCTION
SELECTION
VARIABLE
ENTER DEFAULT EXIT 4.6.9 Code Selection III (Stacked) Menu Page The SCANTEAM 3400PDF autodiscriminates the PDF417 symbology. 4.6.9.1
Macro PDF417
% ($ )% ($
($ 4.6.9.2
Show Macro Control Block
($
4–26
Programming the Reader
Page 60
4.6.9.3. Show GLI Blocks
Enabling this feature causes GLI Commands to be issued where located within their encoded data sequences. When enabled, the “\” is used as an escape character and natural occurrences of “\” in data are replaced by “\\”.
4.6.9.4 One Pass
If this option is enabled, any partial PDF417 scan will be cleared from memory upon a TRIGGER OFF. Normally PDF scans are saved in memory until either a DECODE or a new PDF417 label is scanned. If a new label is detected, the partial data will be cleared, but it is not always possible for the reader to know when a new label is introduced.
4.6.9.5 Notify When Certain
If this option is enabled, the reader sends out a message (ASCII decimal 23) to notify the host system that a successful PDF417 decode is certain; no more scanning is required.
For example, in a machine-mount system, a host computer moves a PDF417 label back and forth in front of the PDF Capable reader until the ASCII decimal 23 is received. At that point scanning is completed, and the decoded message will follow.
4.6.9.6 | When To Decode
The PDF Capable reader must temporarily halt scanning in order to perform PDF417 decoding. A refined algorithm automatically predicts when enough information has been scanned to insure a successful decode. If the scanned data contains many errors, though, decoding cannot succeed and more scanning is required.
In a machine-mount system with a predetermined scan cycle, it may be an advantage to use Trigger-Off Decoding. When this option is enabled the reader will not attempt to decode PDF417 until a TRIGGER OFF. During the predetermined scanning time, the reader is sure to be collecting data.
Programming the Reader 4-27