The text of a manual · part 2 of 3
SCANTEAM 3400 Series Laser Emulation User's Guide, pages 11 to 20
Pages 11 to 20 of 29
The original document is the PDF (278 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP ST3400
Page 11
Scanner Identification (3400LR)
Welch Allyn WA |
SKANEATELES FALLS, NY 13153-0187 USA
3400LR/F-103 1. 1=B=A=1.2 -04-1
DATE - S/N H 234 VUMRINT TVA OTT A
This device complies with Part IS of the FCC Rules. See instruction manual. MADE IN USA PATENT 5,294, 783 D)
ITEM * SOFTWARE REV
SCANTEAM 3400LR Identification Label
Scan Rate @ F = 50 Scans/Second
ITEM#
3400LR/F - 103 0 000
Trigger Option @
Focal Distance @
1 = Manual Trigger
3 = reads medium density codes from 0 - 6”
Interface Option ©
Option IBM OCIA Barlmage Wand TTL True Keyboard RS- - 232 P 4683 OCR Laser Out Emulation RS - 232 RS - 232 Wedge Wedge 0 e 1 e e e e e Various 2 e e e e Various 3 e DEC Only e
6 Getting Started
Page 12
Connecting the Scanner Install the scanner by following the steps shown below:
➊
Disconnect power to the terminal/computer by turning the host system power switch to the “OFF” position.
➋
Connect the interface cable to the scanner and to the decoder unit attached to your terminal/computer.
2
1
-- Getting Started
7
Page 13
➌
Once the scanner has been fully connected, restore power to the terminal/computer by turning the host system power switch to the “ON” position.
-
➍
The 3400 is ready to scan bar code for your application.
8
Getting Started
Page 14
Scanning Techniques The scanning technique for a single bar code (on a page or an object) is shown below.
➊
Move the 3400 Vertically
➋
The illustration below shows where to aim the red illuminated beam over the bar code for a good read.
-
-
Getting Started
9
Page 15
The scanning technique for multiple bar codes (on a page or object) is shown below.
➊
Move the 3400 Horizontally
➋
Note:
10
The techniques shown are for a 3400 with automatic trigger. To scan with a manual trigger, aim the 3400 at a bar code and press the trigger (like step 2).
Getting Started
Page 16
PRODUCT SPECIFICATIONS AND PINOUTS
Environmental Specifications parameter specification
Operating Temperature Storage Temperature
32° F to 122° F [0°C to 50°C] –40° F to 158° F [–40°C to 70°C]
Humidity
0% to 95% RH noncondensing
Barometric Pressure
101,000 to 69,000 Pascals [Sea level to 3,000 meters]
Mechanical Shock
Functional after ten 5ft. [1.5m] drops
ESD Sensitivity
Functional after 15KV discharge
Ambient Illumination
3,000 lux (in contact with bar code)
Modular Connector Life
750 insertions / disconnections
Electrical Specifications (3400-XX1, XX2) parameter specification
Operating Voltage
5 VDC ± 10%
5VDC Input only Current Draw (3400–X0X)
50 Scans/Sec 55mA
Standby Current (3400/X–1XX)
less than 3mA
In–Rush Current
400mA maximum
Power Supply Noise Rejection
100mV peak to peak, from 10 to 100KHz
Acquisition Time (Trigger to Output)
100msec maximum
Mean Time Between Failure (MTBF)
50,000 hours (for ground benign)
100 Scans/Sec 80mA
Product Specifications and Pinouts
11
Page 17
Electrical Specifications (3400LR) parameter specification
Operating Voltage
5 VDC ± 10%
5VDC Input only Current Draw (3400LR/F–103)
50 Scans/Sec 140mA
Standby Current (3400LR/F–103)
less than 3mA
In–Rush Current
400mA maximum
Power Supply Noise Rejection
100mV peak to peak, from 10 to 100KHz
Acquisition Time (Trigger to Output)
100msec maximum
Mean Time Between Failure (MTBF)
50,000 hours (for ground benign)
12
Product Specifications and Pinouts
Page 18
Scanner Performance (3400-XX1, XX2) parameter specification
Pitch Angle
± 7 degrees
Skew Angle
± 30 degrees
Minimum Reflective Difference (MRD)
37.5%
Scan Rate
100 or 50 scans per second (factory selectable)
Field Width
2.2 in [55mm] at near contact to 3.0 in [76mm] at 1 in [25mm] from scanner’s nose
Horizontal Scan Velocity
0 to 5 inches [127mm] per second
Illumination
660 nm Visible Red Light Emitting Diodes (LED) with focusing reflector
Working Distance (3400–XX1)
Near contact for high density code
Working Distance (3400–XX2)
From contact to 4 in [10cm] for low to medium density code
Resolution (3400–XX1) (3400–XX2)
5 mil [0.127mm] code density minimum 20 mil [0.508mm] code density minimum
Product Specifications and Pinouts
13
Page 19
Scanner Performance (3400LR) parameter specification
Pitch Angle
± 7 degrees
Skew Angle
± 30 degrees
Minimum Reflective Difference (MRD)
37.5%
Scan Rate
50 scans per second
Field Width
2.2 in [55mm] at near contact to 5.0 in [127mm] at 5 in [127mm] from scanner’s nose
Horizontal Scan Velocity
0 to 5 inches [127mm] per second
Illumination
660 nm Visible Red Light Emitting Diodes (LED) with focusing reflector
Working Distance (3400LR/F–1X3)
From contact to 6 in [15.24cm] for medium density code
Resolution (3400LR/F–1X3)
7 mil [0.178mm] code density minimum
14
Product Specifications and Pinouts
Page 20
Pinouts ❖ Laser Output only: 3400–X0X (Laser Compatible Bar Image) 8 Pin RJ41 Modular Connector (in scanner handle) 8
1 2 3 4
Standard Welch Allyn Color Code Braid Blue Black Orange
5
Green
Digout
6 7 8
Red White Gray
+5VDC Trigger SOS
Pin
1
Signal
Function
N/C Lasen Ground Acknowledge
Cord Shield Laser Enable Supply Ground Turn on Good Read LED or Beeper Digital Bar Code Data Output 5 Volt Power Connection Trigger Signal to Decoder Start of Scan
❖ Standard Laser Cable: for 3400–X0X Terminating Connector: Standard 9 Pin (Type D) Squeeze–to–Release Connector (compatible with Welch Allyn terminals)
5
1
9
6
Signal
Function
1 2
Standard Welch Allyn Color Code Grey Green
SOS Data
3
Orange
ACK
4 5 6 7 8 9
Red White Blue Black Drain Red
+5VDC Trigger Laser ON GRND Shield no connection
Start of Scan Digital Bar Code Signal Output Acknowledge – Good Read to Scanner Power to Scanner Trigger to Ground Scan Enable Ground Cord Shield Only Power to Scanner
Pin
Product Specifications and Pinouts
15