Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 3

SCANTEAM 3400 Series Laser Emulation User's Guide, pages 11 to 20

Pages 11 to 20 of 29

The original document is the PDF (278 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the HHP ST3400

Page 11 read from a scan by OCR; it may hold reading errors

Scanner Identification (3400LR)

Welch Allyn WA |

SKANEATELES FALLS, NY 13153-0187 USA

3400LR/F-103 1. 1=B=A=1.2 -04-1

DATE - S/N H 234 VUMRINT TVA OTT A

This device complies with Part IS of the FCC Rules. See instruction manual. MADE IN USA PATENT 5,294, 783 D)

ITEM * SOFTWARE REV

SCANTEAM 3400LR Identification Label

Scan Rate @ F = 50 Scans/Second

ITEM#

3400LR/F - 103 0 000

Trigger Option @

Focal Distance @

1 = Manual Trigger

3 = reads medium density codes from 0 - 6”

Interface Option ©

Option IBM OCIA Barlmage Wand TTL True Keyboard RS- - 232 P 4683 OCR Laser Out Emulation RS - 232 RS - 232 Wedge Wedge 0 e 1 e e e e e Various 2 e e e e Various 3 e DEC Only e

6 Getting Started

Page 12

Connecting the Scanner Install the scanner by following the steps shown below:

➊

Disconnect power to the terminal/computer by turning the host system power switch to the “OFF” position.

➋

Connect the interface cable to the scanner and to the decoder unit attached to your terminal/computer.

2

1

-- Getting Started

7

Page 13

➌

Once the scanner has been fully connected, restore power to the terminal/computer by turning the host system power switch to the “ON” position.

-

➍

The 3400 is ready to scan bar code for your application.

8

Getting Started

Page 14

Scanning Techniques The scanning technique for a single bar code (on a page or an object) is shown below.

➊

Move the 3400 Vertically

➋

The illustration below shows where to aim the red illuminated beam over the bar code for a good read.

-

-

Getting Started

9

Page 15

The scanning technique for multiple bar codes (on a page or object) is shown below.

➊

Move the 3400 Horizontally

➋

Note:

10

The techniques shown are for a 3400 with automatic trigger. To scan with a manual trigger, aim the 3400 at a bar code and press the trigger (like step 2).

Getting Started

Page 16

PRODUCT SPECIFICATIONS AND PINOUTS

Environmental Specifications parameter specification

Operating Temperature Storage Temperature

32° F to 122° F [0°C to 50°C] –40° F to 158° F [–40°C to 70°C]

Humidity

0% to 95% RH noncondensing

Barometric Pressure

101,000 to 69,000 Pascals [Sea level to 3,000 meters]

Mechanical Shock

Functional after ten 5ft. [1.5m] drops

ESD Sensitivity

Functional after 15KV discharge

Ambient Illumination

3,000 lux (in contact with bar code)

Modular Connector Life

750 insertions / disconnections

Electrical Specifications (3400-XX1, XX2) parameter specification

Operating Voltage

5 VDC ± 10%

5VDC Input only Current Draw (3400–X0X)

50 Scans/Sec 55mA

Standby Current (3400/X–1XX)

less than 3mA

In–Rush Current

400mA maximum

Power Supply Noise Rejection

100mV peak to peak, from 10 to 100KHz

Acquisition Time (Trigger to Output)

100msec maximum

Mean Time Between Failure (MTBF)

50,000 hours (for ground benign)

100 Scans/Sec 80mA

Product Specifications and Pinouts

11

Page 17

Electrical Specifications (3400LR) parameter specification

Operating Voltage

5 VDC ± 10%

5VDC Input only Current Draw (3400LR/F–103)

50 Scans/Sec 140mA

Standby Current (3400LR/F–103)

less than 3mA

In–Rush Current

400mA maximum

Power Supply Noise Rejection

100mV peak to peak, from 10 to 100KHz

Acquisition Time (Trigger to Output)

100msec maximum

Mean Time Between Failure (MTBF)

50,000 hours (for ground benign)

12

Product Specifications and Pinouts

Page 18

Scanner Performance (3400-XX1, XX2) parameter specification

Pitch Angle

± 7 degrees

Skew Angle

± 30 degrees

Minimum Reflective Difference (MRD)

37.5%

Scan Rate

100 or 50 scans per second (factory selectable)

Field Width

2.2 in [55mm] at near contact to 3.0 in [76mm] at 1 in [25mm] from scanner’s nose

Horizontal Scan Velocity

0 to 5 inches [127mm] per second

Illumination

660 nm Visible Red Light Emitting Diodes (LED) with focusing reflector

Working Distance (3400–XX1)

Near contact for high density code

Working Distance (3400–XX2)

From contact to 4 in [10cm] for low to medium density code

Resolution (3400–XX1) (3400–XX2)

5 mil [0.127mm] code density minimum 20 mil [0.508mm] code density minimum

Product Specifications and Pinouts

13

Page 19

Scanner Performance (3400LR) parameter specification

Pitch Angle

± 7 degrees

Skew Angle

± 30 degrees

Minimum Reflective Difference (MRD)

37.5%

Scan Rate

50 scans per second

Field Width

2.2 in [55mm] at near contact to 5.0 in [127mm] at 5 in [127mm] from scanner’s nose

Horizontal Scan Velocity

0 to 5 inches [127mm] per second

Illumination

660 nm Visible Red Light Emitting Diodes (LED) with focusing reflector

Working Distance (3400LR/F–1X3)

From contact to 6 in [15.24cm] for medium density code

Resolution (3400LR/F–1X3)

7 mil [0.178mm] code density minimum

14

Product Specifications and Pinouts

Page 20

Pinouts ❖ Laser Output only: 3400–X0X (Laser Compatible Bar Image) 8 Pin RJ41 Modular Connector (in scanner handle) 8

1 2 3 4

Standard Welch Allyn Color Code Braid Blue Black Orange

5

Green

Digout

6 7 8

Red White Gray

+5VDC Trigger SOS

Pin

1

Signal

Function

N/C Lasen Ground Acknowledge

Cord Shield Laser Enable Supply Ground Turn on Good Read LED or Beeper Digital Bar Code Data Output 5 Volt Power Connection Trigger Signal to Decoder Start of Scan

❖ Standard Laser Cable: for 3400–X0X Terminating Connector: Standard 9 Pin (Type D) Squeeze–to–Release Connector (compatible with Welch Allyn terminals)

5

1

9

6

Signal

Function

1 2

Standard Welch Allyn Color Code Grey Green

SOS Data

3

Orange

ACK

4 5 6 7 8 9

Red White Blue Black Drain Red

+5VDC Trigger Laser ON GRND Shield no connection

Start of Scan Digital Bar Code Signal Output Acknowledge – Good Read to Scanner Power to Scanner Trigger to Ground Scan Enable Ground Cord Shield Only Power to Scanner

Pin

Product Specifications and Pinouts

15