Page 51
❖ Bar Code Suffix Selection: Assign ASCII Character Suffix, continued
➍ Refer to the chart below to find the hex value of the suffix you wish to assign.
Hex – ASCII Chart NUL 00 SOH 01 STX 02 ETX 03 EOT 04 ENQ 05 ACK 06 BEL 07 BS 08 HT 09 LF 0A VT 0B FF 0C CR 0D SO 0E SI 0F
DLE 10 DC1 11 DC2 12 DC3 13 DC4 14 NAK 15 SYN 16 ETB 17 CAN 18 EM 19 SUB 1A ESC 1B FS 1C GS 1D RS 1E US 1F
SP 20 ! 21 " 22 # 23 $ 24 % 25 & 26 ' 27 ( 28 ) 29 * 2A + 2B , 2C - 2D . 2E / 2F
0 30 1 31 2 32 3 33 4 34 5 35 6 36 7 37 8 38 9 39 : 3A ; 3B < 3C = 3D > 3E ? 3F
@ 40 A 41 B 42 C 43 D 44 E 45 F 46 G 47 H 48 I 49 J 4A K 4B L 4C M 4D N 4E O 4F
P 50 Q 51 R 52 S 53 T 54 U 55 V 56 W 57 X 58 Y 59 Z 5A [ 5B \ 5C ] 5D ^ 5E _ 5F
` 60 a 61 b 62 c 63 d 64 e 65 f 66 g 67 h 68 i 69 j 6A k 6B l 6C m 6D n 6E o 6F p 70 q 71 r 72 s 73 t 74 u 75 v 76 w 77 x 78 y 79 z 7A { 7B | 7C } 7D ~ 7E DEL 7F
➎ Scan two of the ASCII Bar Codes (next page) that represent the hex digits of the suffix you require. Up to 20 characters may be assigned as a bar code suffix.
➏ Scan “F” twice on the ASCII Bar Code chart to save the suffix assignment.
➐ EXIT Program Mode
3–14
Additional Programming
Page 52
ASCII Bar Codes
O 2K 1 2 3 4 5 6 7 8 9 A B C D E F
SUFFIX
Additional Programming 3-15
Page 53
3.3 Dual Interface Programming SCANTEAM models 3400–X1 and 3400–X2 support Dual Interface, which allows you to connect to two different terminals by switching interface cables. The figure below illustrates Dual Interface.
SCANTEAM 3400 PC Terminal
Terminal Interface Cable
Primary Application
SCANTEAM 3400 Portable Data Terminal
HHLC Interface Cable
Secondary Application
3–16
Additional Programming
Page 54
Dual Interface Programming, continued
The 3400 is compatible with a wide range of terminals in the primary (or single) interface mode. (Primary terminal selection programming is found on page 2–11.) Secondary interface is designed to support a limited set of interfaces common to portable data terminals. These interfaces include: • Hand Held Laser Emulation (HHLC) • Wand Emulation, Code 39 • Wand Emulation, Same Code • RS–232 TTL. The scanner must be programmed for secondary interface, just as it must be for primary interface. To program the 3400 for secondary interface, follow the steps below. (Dual Interface single scan programming codes on the following page.)
➊
While the scanner is connected to the primary terminal interface, scan one of the single bar codes to enable the secondary interface.
Note:
ENTER and EXIT bar codes are not needed for Dual Interface.
➋
Disconnect the primary interface cable from the scanner and attach the secondary interface cable to the scanner.
➌
Attach the secondary interface cable to the secondary terminal and power up the terminal.
➍ Program the desired programmable selections for the secondary interface. These selections include: Prefix/Suffix Reread Delay Buffer Scans Wand Emulation Polarity Trigger Mode Wand Emulation Transmission Rate Symbology selections (including EAN ISBN).
3400–X3 and 3400–18 units do not support Dual Interface.
Additional Programming
3–17
Page 55
Dual Interface Programming, continued
Dual Interface Single Scan Programming Codes ❖ Code 39 Wand Emulation Selection ✽
❖ Same Code Wand Emulation Selection [
[ -
-
❖ RS–232 Selection
❖ Laser Emulation Selection
Dual Interface Programming Notes: •
To change the secondary interface from one selection to another (from HHLC to RS–232, for example), the scanner must be reconnected to the primary interface, and then reprogrammed for the new secondary interface. Connect the scanner to the primary interface cable. Follow steps 1–4 on page 3–17.
3400–X3 and 3400–18 units do not support Dual Interface.
3–18
Additional Programming
Page 56
Dual Interface Programming, continued
•
Scanning “Plug and Play” bar codes (single scan terminal selection bar codes – Section 2.2), or changing the terminal type does not affect Dual Interface settings.
•
RS–232 programmable selections are used by both the primary and secondary interfaces. Changing an RS–232 parameter (such as baud rate or parity), while in primary or secondary mode will affect both interfaces.
Dual Interface selection is not available if the 3400 is programmed for an HP terminal with a Terminal I.D. of 20 or 79, or for a WYSE terminal with a Terminal I.D. of 13–18.
Primary Interface only Selection allows you to temporarily disable the dual interface selection, while retaining your secondary interface setup in memory. If you want to enable the secondary interface again, scan the Enable Dual Interface Selection bar code. ❖ Primary Interface only Selection ✽
❖ Enable Dual Interface Selection
3400–X3 and 3400–18 units do not support Dual Interface.
Additional Programming
3–19
Page 57
3.4 Output Programming Use this section to program the 3400 for Output selections. Scan the bar codes below to default the 3400 to factory settings (✽) for output selections.
➊ ENTER Output Program Mode
➋ DEFAULT All Output Selections
➌ EXIT Output Program Mode
3–20
Additional Programming
Page 58
❖ Beeper Selection
➊ ENTER Program Mode Scan the bar code below to program Beeper selection, then choose the volume you want.
➋ Beeper Selection ➌ Beeper Off
➌ Beeper Low Volume
➌ Beeper Medium Volume
➌ Beeper High Volume ✽
➍ EXIT Program Mode
Additional Programming
3–21
Page 59
❖ Keyboard Style Selection
➊ ENTER Program Mode Scan the bar code below to program Keyboard Style selection, then choose the keyboard style you want.
➋ Keyboard Style Selection ➌ Style A ✽ ➌ Style B ➌ Style C ➌ Style D ➌ Style F Yes
No
➌ Style G
3–22
Additional Programming
Page 60
Keyboard Style Selection, continued
➌ Style H Yes
No
➌ Style I
Yes
No
➌ Style J
Yes
No
➍ EXIT Program Mode
The charts on the following pages show the keyboard style for supported terminals. Note: Styles A, B, and C cannot be used with one another; however they may be combined with other styles. All styles with Yes / No bar codes can be scanned in combination with all other styles. For example, you can combine style F with G. First scan F, then scan G. If Style D is combined with another style, D must be scanned first. For example, scan D before scanning B to enable both the CTRL ASCII and the CAPS LOCK functions. Scanning Style A disables Style D.
Additional Programming
3–23