The text of a manual · part 18 of 19
SCANTEAM 3400 Series Decoded Output Operating Guide and Programming Menu, pages 171 to 180
Pages 171 to 180 of 189
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP ST3400
Page 171
B–2
Hex ASCII Chart
Page 172
3400/B AND 3400LR/C INFORMATION
C
The following pages describe the 3400/B and 3400LR/C scanners. These scanners use the same programming methods detailed in this User’s Guide, but their identification labels, performance, and specifications differ from the 3400LR and 3400HD.
3400/B and 3400LR/C Information
C–1
Page 173
C.1 Scanner Identification (3400/B)
| Welch Allyn WA |
SKANEATELES FALLS, NY 13153-0187 USA ITEM # SOFTWARE REV
|. |=B=A=1.2 DATE - S/N H-04- 1234 UTARIAY A OW A This device complies with Part I5 of the FCC Rules. See instruction manual. /
3400/B- 122
MADE IN USA PATENT 5,294, 783
Scan Rate @
ITEM#
3400/B - 122
B = 100 Scans/Second E = 50 Scans/Second
0 800
Trigger Option @
Focal Distance @
0 = Auto Trigger 1 = Manual Trigger
1 = reads high density code in contact 2 = reads low density code from 0 to 4” [10cm]
Interface Option ©
Option IBM OCIA Barlmage Wand TTL True Keyboard RS - 232 p 4683 OCR LaserOut Emulation RS - 232 RS - 232 Wedge Wedge 0 e 1 e e e e e Various 2 e e e e Various 3 e DEC Only e
3400/B and 3400LR/C Information
Page 174
C.2 Scanner Identification (3400LR/C)
Welch Allyn WA
SKANEATELES FALLS, NY 13153-0187 USA ITEM # 3400LR/C - 123 SOFTWARE REV 1|.1=B=A=1.2
DATE - S/N H-04- 1234 UTRRIAY 1 OT AY
This device complies with Part I5 of the FCC Rules. See instruction manual. MADE IN USA PATENT 5,294, 783 D)
SCANTEAM 3400LR/C Identification Label
Scan Rate @ ITEM# 3400LR/C-123 C = 120 Scans/Second 0 000
Trigger Option @ || Focal Distance @
0 = Auto Trigger 3 = reads medium density codes from 0 - 6” 1 = Manual Trigger
Interface Option © IBM OCIA Barlmage Wand TTL True Keyboard RS - 232
Option 4683 OCR LaserOut Emulation RS - 232 RS - 232 Wedge Wedge 1 e e e e e Various 2 e e e e Various 3 e DEC Only e
3400/B and 3400LR/C Information C-3
Page 175
C.3 Scanning Performance The following figures illustrate the 3400/B and 3400LR/C’s Scanner Performance or depth of field. Depth of field is the range of distances over which a scanner can accurately digitize a bar code. This distance is measured from the front of the scanner at the exit window and is dependent on code size, contrast, and quality. Depth of field is equal to the far distance minus the near distance distance). The first figure shows the depth of field for a contact scanner and the second figure shows the depth of field for a non–contact scanner.
SCANTEAM 3400 Depth of Field Contact Scanner
C–4
3400/B and 3400LR/C Information
Page 176
) cob lanl
Nears SK
SSSSS SKY SKS SOS aces
SKS KOO aceee
& oS ge
7.9 mil TYPICAL
13 mil
TYPICAL
SC ANTEAM 3400 Depth of Field Non-C ontact Scanner
Welch Allyn WA |
SCANTEAM"3400 /
3400/B and 3400LR/C Information C- - 5
Page 177
C.4 Environmental Specifications parameter specification
Operating Temperature Storage Temperature
32° F to 122° F [0°C to 50°C] –40° F to 158° F [–40°C to 70°C]
Humidity
0% to 95% RH noncondensing
Barometric Pressure
101,000 to 69,000 Pascals [Sea level to 3,000 meters]
Mechanical Shock
Functional after ten 5ft. [1.5m] drops
ESD Sensitivity
Functional after 15KV discharge
Ambient Illumination
3,000 lux (in contact with bar code)
Modular Connector Life
750 insertions / disconnections
C.5 Electrical Specifications (3400–XX1, XX2) parameter specification
Operating Voltage
5 VDC ± 10%
5VDC Input only Current Draw (3400–X0X) Current Draw (3400–X1X) Current Draw (3400–X2X) Current Draw (3400–X3X)
50 Scans/Sec 55mA 175mA 125mA 165mA
Standby Current (3400/X–1XX)
100µA
In–Rush Current
400mA maximum
Power Supply Noise Rejection
100mV peak to peak, from 10 to 100KHz
Acquisition Time (Trigger to Output)
100msec maximum
Mean Time Between Failure (MTBF)
50,000 hours (for ground benign)
C–6
3400/B and 3400LR/C Information
100 Scans/Sec 80mA 200mA 150mA 190mA
Page 178
C.6 Electrical Specifications (3400LR/C) parameter specification
Operating Voltage
5 VDC ± 10%
5VDC Input only Current Draw (3400LR/C–X03) Current Draw (3400LR/C–X13) Current Draw (3400LR/C–X23) Current Draw (3400LR/C–X33)
120 Scans/Sec 180mA 240mA 230mA 230mA
Standby Current (3400LR/C–1X3)
100µA
In–Rush Current
400mA maximum
Power Supply Noise Rejection
100mV peak to peak, from 10 to 100KHz
Acquisition Time (Trigger to Output)
100msec maximum
Mean Time Between Failure (MTBF)
50,000 hours (for ground benign)
3400/B and 3400LR/C Information
C–7
Page 179
C.7 Scanner Performance (3400–XX1, XX2) parameter specification
Pitch Angle
± 7 degrees
Skew Angle
± 30 degrees
Minimum Reflective Difference (MRD)
37.5%
Scan Rate
100 or 50 scans per second (factory selectable)
Field Width
2.2 in [55mm] at near contact to 3.0 in [76mm] at 1 in [25mm] from scanner’s nose
Horizontal Scan Velocity
0 to 5 inches [127mm] per second
Illumination
660 nm Visible Red Light Emitting Diodes (LED) with focusing reflector
Working Distance (3400–XX1)
Near contact for high density code
Working Distance (3400–XX2)
From contact to 4 in [10cm] for low to medium density code
Resolution (3400–XX1) (3400–XX2)
5.0 mil [0.127mm] code density minimum 7.0 mil [0.178mm] code density minimum
C–8
3400/B and 3400LR/C Information
Page 180
C.8 Scanner Performance (3400LR/C) parameter specification
Pitch Angle
± 7 degrees
Skew Angle
± 30 degrees
Minimum Reflective Difference (MRD)
37.5%
Scan Rate
120 scans per second
Field Width
2.2 in [55mm] at near contact to 5.0 in [127mm] at 4 in [101.6mm] from scanner’s nose
Horizontal Scan Velocity
0 to 5 inches [127mm] per second
Illumination
660 nm Visible Red Light Emitting Diodes (LED) with focusing reflector
Working Distance (3400LR–XX3) From contact to 6 in [15.2cm] for medium density code Resolution (3400LR–XX3)
7 mil [0.178mm] code density minimum
3400/B and 3400LR/C Information
C–9