The text of a manual · part 15 of 19
SCANTEAM 3400 Series Decoded Output Operating Guide and Programming Menu, pages 141 to 150
Pages 141 to 150 of 189
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP ST3400
Page 141
❖ Supported Interface Keys HP 700/92 Supported Interface Keys NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
4–12
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
Interface Keys
Key Function RESERVED ENTER CAPS RESERVED RESERVED RESERVED RESERVED RESERVED BACKSPACE TAB RESERVED RESERVED RESERVED RETURN RESERVED RESERVED HOME RESERVED RESERVED RESERVED RESERVED CLEAR SCREEN F1 F2 F3 F4 F5 ESCAPE F6 F7 F8 RESERVED
Page 142
❖ Supported Interface Keys ASCII/ANSI keyboards for WYSE WY–60/150 Supported Interface Keys NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
Key Function RESERVED NEW LINE INSERT/PF1 DELETE/PF2 CLEAR/PF3 F11 F12 NEW LINE REPLACE/PF4 TAB FORWARD F13 F14 F15 NEW LINE INSERT CURSOR UP CURSOR LEFT CURSOR DOWN CURSOR RIGHT BACKSPACE PRINT F16 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10
Interface Keys
4–13
Page 143
❖ Supported Interface Keys WYSE WY–30 Supported Interface Keys NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
4–14
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
Interface Keys
Key Function RESERVED ENTER RESERVED RESERVED RESERVED RESERVED RESERVED RETURN RESERVED TAB LINE FEED RESERVED RESERVED RETURN RESERVED CURSOR UP CURSOR LEFT CURSOR DOWN CURSOR RIGHT BACKSPACE RESERVED RESERVED F1 F2 F3 F4 F5 (CTRL F1) F6 (CTRL F2) F7 (CTRL F3) F8 (CTRL F4) F9 (SHIFT F2) F10 (SHIFT F3)
Page 144
FULL ASCII CODE 39 BAR CODE CHART
%U (NUL)
$H (BS)
$A (SOH)
$I (HT)
$B (STX)
$J (LF)
$C (ETX)
$K (VT)
$D (EOT)
$L (FF)
$E (ENQ)
$M (CR)
$F (ACK)
$N (SO)
$G (BEL)
$O (SI)
Code 39 Chart
4–15
Page 145
4–16
$P (DLE)
$X (CAN)
$Q (DC1)
$Y (EM)
$R (DC2)
$Z (SUB)
$S (DC3)
%A (ESC)
$T (DC4)
%B (FS)
$U (NAK)
%C (GS)
$V (SYN)
%D (RS)
$W (ETB)
%E (US)
Code 39 Chart
Page 146
5
PRODUCT SPECIFICATIONS AND PINOUTS
5.1 Environmental Specifications parameter specification
Operating Temperature Storage Temperature
32° F to 122° F [0°C to 50°C] –40° F to 158° F [–40°C to 70°C]
Humidity
0% to 95% RH noncondensing
Barometric Pressure
101,000 to 69,000 Pascals [Sea level to 3,000 meters]
Mechanical Shock
Functional after ten 5ft. [1.5m] drops
ESD Sensitivity
Functional after 15KV discharge
Ambient Illumination
Standard 3400LR and 3400HD = 10,000 lux 3400-18 = 3,000 lux
Modular Connector Life
750 insertions / disconnections
Specifications and Pinouts
5–1
Page 147
5.2 Electrical Specifications parameter specification
Operating Voltage
5 VDC ± 10%
5VDC Input only Current Draw (3400–X0) Current Draw (3400–X1) Current Draw (3400–X2) Current Draw (3400–X3) Current Draw (3400–18)
50 Scans/Sec 80mA N/A N/A N/A N/A
Standby Current (3400–1X)
100µA
In–Rush Current
400mA maximum
Power Supply Noise Rejection
100mV peak to peak, from 10 to 100KHz
Acquisition Time (Trigger to Output)
100msec maximum
Mean Time Between Failure (MTBF)
50,000 hours (for ground benign)
110 Scans/Sec N/A 180mA 170mA 170mA 180mA
5.3 Scanner Performance parameter specification
Pitch Angle
± 7 degrees
Skew Angle
± 30 degrees
Minimum Reflective Difference (MRD)
37.5%
Scan Rate
112 or 50 scans per second (set at factory)
Horizontal Scan Velocity
0 to 5 inches [127mm] per second
Illumination
660 nm Visible Red Light Emitting Diodes
Resolution
(3400HD) (3400LR)
5–2
4.0 mil [0.102mm] code density minimum 7.0 mil [0.178mm] code density minimum
Specifications and Pinouts
Page 148
5.4 Pinouts ❖ Laser Output only 3400–X0 (Laser Compatible Bar Image)
Conventional laser data format provided at 10 pin RJ41 modular connector (in scanner handle). See chart below. 10 Pin RJ41 Modular Connector 10
Pin 1 2 3 4
Standard Welch Allyn Color Code N/C Braid Blue Black Orange
1
Signal
Function
N/C Lasen Ground Acknowledge
Cord Shield Laser Enable Supply Ground Turn on Good Read LED or Beeper Digital Bar Code Data Output
5 Green
Digout
8
Red White
+5VDC Trigger
5 Volt Power Connection Trigger Signal to Decoder
9
Gray
SOS
Start of Scan
10
N/C
6 7
Specifications and Pinouts
5–3
Page 149
❖ Standard Laser Cable for 3400–X0 (Laser Compatible Bar Image)
Interface cables normally supplied with SCANTEAM 3400–X0 scanners are terminated with a 9 pin Type D (squeeze–to–release) connector that is compatible with all Welch Allyn terminals. See chart below. Terminating Connector: Standard 9 Pin Squeeze–to–Release Connector
5
1
9
6
Signal
Function
1 2
Standard Welch Allyn Color Code Grey Green
SOS Data
3
Orange
ACK
Start of Scan Digital Bar Code Signal Output Acknowledge – Good Read to Scanner
4
Red
5 6 7 8 9
White Blue Black
Pin
Drain Red
♦ +5VDC or no connection Trigger Laser ON GRND Shield +12VDC or no ♦ connection
Power to Scanner Trigger to Ground Scan Enable Ground Cord Shield Only Power to Scanner
(♦) Pins 4 and 9 are populated depending on power supply voltage option.
5–4
Specifications and Pinouts
Page 150
❖ Keyboard Wedge 3400–X1, 3400–X2, 3400–18
Decoded output data format provided at 10 pin RJ41 modular connector (in scanner handle). See chart below. 10 Pin RJ41 Modular Connector 10
1 2 3 4 5 6 7 8 9
Standard Welch Allyn Color Code N/C Braid Blue Black Orange Green Red White Gray
10
N/C
Pin
Signal
Function
N/C Prog 1 Ground Tclock Tdata +5VDC Kdata Kclock
Cord Shield
1
Supply Ground Terminal Clock Terminal Data 5 Volt Power Connection Keyboard Data Keyboard Clock
Specifications and Pinouts
5–5