❖ Reread Delay Selection

➊ ENTER Program Mode Scan the bar code below to program Reread Delay selection, then choose the delay you want.

➋ Reread Delay Selection ➌ Low ✽

➌ Medium

➌ High

➌ Extra High

➍ EXIT Program Mode

3–84

Additional Programming

Page 122

❖ Good Read Delay Selection

➊ ENTER Program Mode Scan the bar code below to program Good Read Delay selection, then choose the delay you want.

➋ Good Read Delay Selection ➌ None ✽

➌ Low (500 milliseconds)

➌ Medium (1.0 second)

➌ High (1.5 seconds)

➍ EXIT Program Mode

Additional Programming

3–85

Page 123

3.10

Wand Emulation and Laser Output Programming

Use this section to program the 3400 for Wand Emulation and Laser Output selections. Scan the bar codes below to default the 3400 to factory settings (✽) for wand emulation and laser output selections.

➊ ENTER Wand Emulation and Laser Output Program Mode

➋ DEFAULT All Wand Emulation and Laser Output Selections

➌ EXIT Wand Emulation and Laser Output Program Mode

3400–X3 and 3400–18 units do not support Wand Emulation and Laser Output.

3–86

Additional Programming

Page 124

❖ Output Polarity Selection

➊ ENTER Program Mode Scan the bar code below to program Output Polarity selection, then choose the polarity you want.

➋ Output Polarity Selection (Wand and Laser Emulation)

➌ White High (“Laser”) ✽ [

➌ Black High [

[ In Laser Emulation mode, the default output polarity is white high. In Wand Emulation mode, the default output polarity is black high.

➍ EXIT Program Mode

3400–X3 and 3400–18 units do not support Output Polarity.

Additional Programming

3–87

Page 125

❖ Transmission Rate Selection

➊ ENTER Program Mode Scan the bar code below to program Transmission Rate selection, then choose the transmission rate you want.

➋ Transmission Rate Selection ➌ 10 ips (inches per second)

➌ 120 ips (inches per second)

➌ 25 ips (inches per second) ✽

➌ 150 ips (inches per second)

➌ 40 ips (inches per second)

➌ 200 ips (inches per second)

➌ 80 ips (inches per second)

➍ EXIT Program Mode 3400–X3 and 3400–18 units do not support Transmission Rate.

3–88

Additional Programming

Page 126

❖ Data Sync / Wake Up Selection [

➊ ENTER Program Mode Scan the bar code below to program Data Sync / Wake Up Signal, then choose enable or disable.

➋ Data Sync / Wake Up Signal ➌ Enable (Yes)

➌ Disable (No ✽)

➍ EXIT Program Mode Default = Off (Disable / No). If enabled, the scanner generates a sync / wake up pulse when the trigger switch is activated to alert the decoder or portable terminal that digital bar code data will follow. The bar code data is transmitted after a 200 millisecond delay from the start of pulse.

- - - -

[ A unique wand emulation cable is required to support this feature.

Refer to the IPWC Interface/Cable Matrix for the cable part number.

Additional Programming

3–89

Page 127

3.11

Status Check

Use this section to request a 3400 Status Check. Scan the ENTER bar code to start Status Check.

➊ ENTER Status Check Mode Scan the bar code below to show formats status. One format per line will be printed out.

➋ Show Formats

➊ ENTER Status Check Mode Scan the bar code to show the software revision level. The software revision for retail terminals will be printed out as “3960XXXX.” The software revision for non–retail terminals will be printed out as “3960–XX Rev. X.X.” (The “X’s” stand for the revision level.)

➋ Show Software Revision

There are no default settings for status check selections. After Formats and/or Software Revision have printed out, the 3400 will automatically EXIT programming mode.

3–90

Additional Programming

Page 128

3.12

SCANTEAM 3400 Cloning Instructions

Procedure: 1)

Connect the 4 pin female mini–DIN on the cloning cable (p/n 42204559–01) to the power supply (PS5/C).

2)

Connect the SOURCE* unit to one of the 10 pin modular connectors on the cloning cable.

3)

Connect the DESTINATION* unit to the remaining 10 pin modular connector on the cloning cable. Scan the “Destination” cloning bar code.

“Destination” Cloning Bar Code

4)

Scan the “SOURCE” cloning bar code. The unit’s green LED will flash on and off. This process takes about 15 seconds.

“Source” Cloning Bar Code

5)

When cloning is complete, the SOURCE* unit will flash its green LED on and off.

6)

Unplug the DESTINATION* unit from the cloning cable.

7)

To clone another unit, repeat steps 3 through 5.

*Note:

The SOURCE unit is the unit containing the desired firmware. The SOURCE unit may be an original “Master” unit, or a unit that has been cloned from the “Master” unit. The DESTINATION unit is the unit which needs to be updated from the SOURCE or “Master” unit.

Caution: DO NOT scan the “source” bar code unless you are going to clone a unit. If you do, you may lock up your unit and will have to turn the power off and back on.

Additional Programming

3–91

Page 129

3–92

Additional Programming

Page 130

4

SUPPORTED INTERFACE KEYS

4.1 Keyboard Function Relationships The following Keyboard Function Code, HEX/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the SCANTEAM 3400 Hand Held CCD scanner. Function Code NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

HEX/ASCII Value 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

Full ASCII “CTRL” + 2 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] 6 -

Interface Keys

4–1