Page 101
❖ MSI Selection
➊ ENTER Program Mode Scan the bar code below to start MSI symbology selection, then enable or disable MSI decoding.
➋ MSI Selection ➌ Enable (Yes)
➌ Disable (No ✽)
Note:
If you don’t need to program additional selections, you may scan EXIT now to exit program mode and save your changes.
To set minimum allowable length, scan the “Set Minimum Length” bar code, then refer to the Retail Symbologies Min/Max Length chart (page 3–67). Scan two of the Numeric Bar Codes (below the Length chart) to set the length. Repeat the process to set maximum length.
➍ Set Minimum Length ➍ Set Maximum Length
➎ EXIT Program Mode
3–64
Additional Programming
Page 102
❖ Plessey Selection
➊ ENTER Program Mode Scan the bar code below to start Plessey symbology selection, then enable or disable Plessey decoding.
➋ Plessey Selection ➌ Enable (Yes)
➌ Disable (No ✽)
Note:
If you don’t need to program additional selections, you may scan EXIT now to exit program mode and save your changes.
To set minimum allowable length, scan the “Set Minimum Length” bar code, then refer to the Retail Symbologies Min/Max Length chart (page 3–67). Scan two of the Numeric Bar Codes (below the Length chart) to set the length. Repeat the process to set maximum length.
➍ Set Minimum Length ➍ Set Maximum Length ➎ EXIT Program Mode
Additional Programming
3–65
Page 103
❖ Disable All Symbologies
➊ ENTER Program Mode Scan the bar code below to Disable ALL Symbologies. Caution:
You will not be prompted to verify this option.
➋ Disable All Symbologies
➌ EXIT Program Mode
Note:
All Industrial Symbologies will be disabled also.
3–66
Additional Programming
Page 104
Retail Symbologies Min/Max Length Chart
Symbology Minimum Length Maximum Length MSI 04 * 48 * Plessey 04 * 48 *
Numeric Bar Codes
0
2
4 5 6
7 8 9
1 3
RETAIL CODES
Additional Programming 3-67
Page 105
3.7 RS–232 Programming Use this section to program the 3400 for RS–232 selections. Scan the bar codes below to default the 3400 to factory settings (✽) for RS–232 selections.
➊ ENTER RS–232 Program Mode
➋ DEFAULT All RS–232 Selections
➌ EXIT RS–232 Program Mode
3–68
Additional Programming
Page 106
❖ Baud Rate Selection
➊ ENTER Program Mode Scan the bar code below to program Baud Rate selection, then choose the baud rate you want.
➋ Baud Rate Selection ➌ 300 bps (bits per second)
➌ 4800 bps (bits per second)
➌ 600 bps (bits per second)
➌ 9600 bps (bits per second) ✽
➌ 1200 bps (bits per second)
➌ 19200 bps (bits per second)
➌ 2400 bps (bits per second)
➌ 38400 bps (bits per second)
➍ EXIT Program Mode
Additional Programming
3–69
Page 107
❖ Parity Selection
➊ ENTER Program Mode Scan the bar code below to program Parity selection, then choose the parity you want.
➋ Parity Selection ➌ None
➌ Mark
➌ Space
➌ Odd
➌ Even ✽
➍ EXIT Program Mode
3–70
Additional Programming
Page 108
❖ Data Format Selection
➊ ENTER Program Mode Scan the bar code below to program Data Format selection, then choose the data format you want.
➋ Data Format Selection ➌ 7 Data, Parity, 1 Stop ✽
➌ 7 Data, Parity, 2 Stop
➌ 8 Data, Parity, 1 Stop
➍ EXIT Program Mode
Additional Programming
3–71
Page 109
❖ CTS Handshake Selection
➊ ENTER Program Mode This selection allows you to disable the CTS Handshake if your terminal/computer doesn’t have a CTS I/O line. Scan the bar code below to program CTS Handshake selection, then choose enable or disable.
➋ CTS Handshake Selection ➌ Enable (Yes)
➌ Disable (No ✽)
CTS Handshake only applies when the 3400 is in Serial Mode (RS–232, TTL or True).
➍ EXIT Program Mode
3–72
Additional Programming
Page 110
❖ Serial Wedge Selection
➊ ENTER Program Mode Scan the bar code below to program Serial Wedge selection, then choose the Operating Mode Output Direction you want.
➋ Serial Wedge Selection (Model 3400–X3 only)
➌ To P1 ✽ [
➌ To P2 [
➌ To P1 and P2 [
[ P1 and P2 are serial wedge designations printed on the serial wedge cable.
➍ EXIT Program Mode
Additional Programming
3–73