For the HHP ST1100

Page 1 read from a scan by OCR; it may hold reading errors

SCANTEAM 100/200 wae

Wi Welch Allyn

1100/1200/PM Rev C Skaneatcles Fall Now York 13153-0187 Welch Al lyn

Page 2 read from a scan by OCR; it may hold reading errors

Welch Allyn WA scANTEAM 1200, 1100 Series USER'S Welch Allyn WA MSR BAR CODE CHART SCANTEAM 1200, 1100 Series

NOTES MAGNETIC STRIPE READER USE THIS PAGE a . @ In combination with the adjoining menu pages to program decoder. SCANTEAM 1 200, 11 00 Series @ The bar codes-on this page correspond to symbols in shaded areas on adjoining menu pages. SCAN these bar codes in the sequence Programming Menu indicated on menu page to program desired selections and variables. USE THIS PAGE @ To select the pre-programmed asterisked (*) values by scanning DEFAULT symbol. @ To configure the Magnetic Stripe Reader (MSR) Port. roman numerals letters digits others HI | | selections EI variables LSCAN JESCAN] | | | | | en l A 0 (YES) ~- STATUS ENTER Track 1 4 Enable Minimum (2) | aT team VMI) KI) | | lh Tracks2&3 0 (TI Enable _ - =s ee N B 1 (NO) ESCAPE Minimum (2) . _ = - _" VON AIM UUM UN Start/Stop i Enable | ; CharacterXmit eat Cc 2 CLEAR eee BLOCK BUFFER LRC Character iy Enable Xmit : IV D 3 DELETE PREVIOUS Vv E 4 SEND UI) su VI F 5 SCROLL RIGHT Vi G 6 SCROLL LEFT VII H 7 BEGIN PROMPT IX I 8 END PROMPT x J 9 DEFAULT

NOTES

(1) * Designates DEFAULT settings. (2) The DEFAULT Minimum Length is 4 characters. (3) The DEFAULT Maximum Length is 76 characters. EXIT EXIT

(4) The DEFAULT Maximum Length is 37 characters. 17 18

Page 3 read from a scan by OCR; it may hold reading errors

CODES SCANTEAM 1200, 1100 Series Welch Allyn WA CODE SELECTION | INDUSTRIAL Information and Examples (INDUSTRIAL)

SCANTEAM 1200, 1100 Series Programming Menu

INDUSTRIAL CODE QUTPUT FORMATS

USE THIS PAGE CODABAR aSX ..... xs @ To select the pre-programmed asterisked (*) values by scanning DEFAULT symbol. Code 3 of 9 bSXX .... XXCS @ To enable or disable listed code selections. INTERLEAVED 2 of 5 eXX ..... XXC 20f 5 fXX 2.20. XX

Code 11 NXX ..... XXCC

LSCAN |

Code 93 iXX ...... XX

Code 128 jXX .. 2 XX selections EDI variables LSCAN JM SCAN] ENTER

Matrix 2 of 5 MXX..... XX Codabar (ID =a) 1 Enable Minimum Length

Where: a = CODABAR Code ID LSCAN | Maximum Length b =Code3 of 9!ID S78 Xenit e = Interleaved 2 of 51D - f =20f5ID Check Char. Req'd h = Code 111D Xmit Check Char. i = Code 93 1D DEFAULT ; Concantenation j = Code 128 ID _ m = Matrix 2 of 5 Code 39 (ID = b) Enable S = Start/Stop Character Minimum Length X = Data Character Maximum Length C = Checksum Character S/S Xmit ; oo. Check Char. Req'd NOTE: Proper parameters must be turned on for code identification. Start/stop and Checksum Xmit Check Char characters to be transmitted. For maximum data security, disable the Codes not used. Full Ascii - U FULL ASCII CODE 3 OF 9 CHARACTERS Append Option If full ASCII Code 3 of 9 decoding is enabled, certain character pairs within the bar code symbol Interleaved 2of5 | iif Enable will be interpreted as a single character. For example: $V will be decoded as the ASCII character (ID =e) Minimum Length(2) 02. SYN and /C will be decoded as the ASCII character #. Maximum Length 8 MIN-80" 6, 14 & 16 Only c Yes/No" FULL ASCII CODE 3 OF 9 CHART Check Digit Reqd 9 Yes/No* NUL %U DLE $P SPs 0 0 o Pp oP mW +P Xmit Check Digit = YesiNo’ Yes/No: conta Caio em a es Code 2 of 5 iv” Enable *Yes/No STX $B DC2 $R "1B 2 2 BB R oR b +B r +R (ID = f) Minimum Length(2) A O1-MAX ETX $C Dc3 $s # 1c 3. 3 cc s $s e +c ss +8 - EOT sD DC4 $T s 10 44 D oD ™ T d 4D t 4 ___ Maximum Length __B MIN-487 ENQ SE NAK $U % /E 5 §, E € uu e +E vu + Matrix 2 of 5 VY Enable "Yes/No ACK SF SYN $V & IF 6 6 FOF voy { +F voo4v -, z BEL $G ETB SW ’ 1G 7 7 G G wow 9 +G wow (ID = m) Minimum Length(2) A OtMAX Length(2) A O1-MAX BS $H CAN $x (| /H 8 8 H oH x x h +H x 4X Maximum Length 8. _MIN-S0" HA j eve pal ) I 9 2 \ 5 M M i 4 M ea Code 11 (ID =h) Vi Enable “Yes/No . : j, VT sk ESC %A + /K 1% K K { %K k +k { %P Minimum Length(2) A O1-MAX FF SL FS %B , on < %G Lou \ %b 1oo4t 1 %Q Maximum Length 8 MIN-80" cR $M GS %C - + = %H MoM } %M m +M + -%R, SO SN RS %D oo, > %l NON %N nN - Ms # Check Digits c et $s! $0 US %E 10 7 2 ed (ne), %0 ° +0 DEL %T%X%Y%Z Code 93, s (ID = i) vil Enable “Yes/No Charact irs /M and /N decod ; ; 4 period tivel Minimum Length “O0-MAX aracter pairs /M an ecode as a minus sign and period respectively. “Maximum Length MINS Character pairs /P through /Y decode as 0 through 9., - - - - - = P 9 9 Code 128 (ID=)) |MiiT Enable “Yes/No MIN/MAX LENGTH Minimum Length *00-MAX These variables are used to require that bar code symbols contain a character count within a Maximum Length MIN-COr certain range. Bar codes with counts outside this range will not be decoded.

EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09

Max. length = 20 LSCAN NOTES . : (1) * Designates DEFAULT selections. EXAMPLE: Decode only those bar codes with a count of 15 characters. (2) The DEFAULT Minimum Length for these codes is 4 characters, Min. length = 15 Max. length = 15 : EXIT

Page 4 read from a scan by OCR; it may hold reading errors

CODES

RETAIL

RETAIL CODE OUTPUT FORMATS

Non-Zero Suppressed UPC-A and UPC-E Output Format

UPC-A UPC-A with 2 digit supplemental UPC-A with 5 digit supplemental UPC-E UPC-E with 2 digit supplemental UPC-E with 5 digit supplemental

Zero Suppressed UPC-A and UPC-E Output Format

UPC-A UPC-A with 2 digit supplemental UPC-A with 5 digit supplemental UPC-E UPC-E with 2 digit supplemental UPC-E with 5 digit supplemental

EAN/JAN Output Format

EAN/JAN-13

EAN/JAN-13 with 2 digit supplemental EAN/JAN-13 with 5 digit supplemental EAN/JAN-8

EAN/JAN-8 with 2 digit supplemental EAN/JAN-8 with 5 digit supplemental

Where: c = UPC Code ID d = EAN/JAN Code ID g =MSI k = AMES n = Plessey

N = Number System Character f = Identification Flag

X = Data Character

C = Checksum Character

~- = Space

S = Supplemental Character

SCANTEAM 1200, 1100 Series Information and Examples

CNXXXXXXXXXXC CNXXXXXXXXXXC-SS cCNXXXXXXXXXXC-SSSSS eNXXXXXXXXXXC CNXXXXXXXXXXC-SS CNXXXXXXXXXXC-SSSSS

CNXXXXXXXXXXC CNXXXXXXXXXXC-SS CNXXXXXXXXXXC-SSSSS CXXXXXX cNXXXXXX-SS cCNXXXXXX-SSSSS dffXXXXXXXXXXC dffXXXXXXXXXXC-SS dffXXXXXXXXXXC-SSSSS dffXXXXXC dffXXXXXC-SS dffXXXXXC-SSSSS

NOTE: Proper parameters must be turned on for code identification, number system, checksum and supplemental characters to be transmitted. For maximum data security, disable the Codes not used. UPC/EAN LENGTH CHART . Basic W/out W/out# W/2Digit W/5 Digit selections Length Ck. Digit Sys. Digit Addendum Addendum TOTAL UPCA 12 -01 -01 +02 +05 UPCE [w/ 0’s suppressed] 8 -01 -01 +02 +05 UPCE [expanded] 12 -01 -01 +02 +05 UPCD1 14 -01 -01 +02 +05 UPCD2 20 -02 -01 +02 +05 UPCD3 24 -02 -01 +02 +05 UPCD4 28 -03 -01 +02 +05 UPCD5 32 -03 -01 +02 +05 EAN8 8 -01 N/A +02 +05 EAN13 13 -01 N/A +02 +05 10

Welch Allyn WA mn vn

DEFAULT

IW

COMMUNICATIONS II

SCANTEAM 1200, 1100 SERIES Programming Menu

USE THIS PAGE @ To select the pre-programmed asterisked (*) values by scanning DEFAULT symbol.

H@ To program Terminal Port Identification (ID) Number. B To select Data Destination. @ To program intercharacter delay and fixed message length.

selections RQyI variables LSCAN BA SCAN | Code ID : Welch Allyn Forma AIM Format Data Dest To Terminal To Host To Display Inter Delay 18 No

Yes srenennennsenni

Enable

Fixed Message Enable Length ; Length (3)

Beep Out Port 2(6)

Fill Character (4) Field Separator (5)

Time Stamp (7)

Enable

NOTES:

(1) Once “WA Network” is selected only the following communications options can be altered: Data Form, Code ID. Data Destination ("To Display” only), Beep Out Port 2 and Fixed Message Length.

(2) * Designates DEFAULT selections.

(3) The DEFAULT Length is 80 characters.

(4) The DEFAULT Fill Character is a space (20 Hex). (5) The DEFAULT Field Separator is “FS” (1C Hex).

(6) Not applicable to the 1100. (7) Block Mode Only.

Page 5 read from a scan by OCR; it may hold reading errors

COMMUNICATIONS II

SCANTEAM 1200, 1100 Series Information and Examples

Code ID, When enabled the symbology of the scanned bar code will be identified by a single lower case letter. The complete listing of Welch Allyn code identifier definitions appears in Appendix section A.10. If AIM Format is enabled, bar code symbologies are identified by the AIM Standard Symbology Identifiers. (Refer to appendix A.8).

Intercharacter Delay, when enabled an intercharacter delay of between 01 to 99 milliseconds can be programmed. If disabled delay will be set to 0. Incoming messages may not have an intercharacter delay greater than one (1) byte time at the programmed baud rate.

Beep Out Port 2, when enabled, permits an external beeper (which meets Welch Allyn specifications) to be driven from Scanner Port 2.

Fixed Message Length, when enabied, terminal can be programmed to transmit data strings a specified number of characters in length.

Length, Specifies message length in total number of characters. Values ranging from 001-512in Standalone and 001 - 128 in Network may be specified.

Fill Character, Fill characters are used to add characters to the message in order to increase it to the ‘fixed’ length. Only one character can be selected but any value between 00 and 7F Hex can be used.

Field Separator, Used to separate two or more bar code data entries within the same message. Adds to the total character count of ‘fixed’ message length.

EXAMPLE: FIXED MESSAGE LENGTH

The following fixed length message is structured to contain two bar code inputs

Specified Message Length, 30 Characters Bar Code Length, 12 Characters

Field Separator, 00 Hex

Fill Characters, 07 Hex

MESSAGE FORMAT: CCCCCCCCCCCC 1D1 00 CCCCCCCCCCCC ID2 00 07 «+07 Bar Code Code ID Field Bar Code Code ID Field Fill Data 1 for Bar Separator Data 2 forBar Separator Characters Code 1 Code 2

Time Stamp, Used to include a time stamp with every scan or keyed entry while in block mode.

TIME STAMP FORMAT: CCCCCCC SPC HH : MM =: SS Bar Code Space Hour Minutes Seconds Data (Hex 20) 6

Welch Allyn WA

TT

ENTER

WW

DEFAULT wt

EXIT

CODE SELECTION II

(RETAIL)

SCANTEAM 1200, 1100 Series Programming Menu

USE THIS PAGE @ To select the pre-programmed asterisked (*) values by scanning DEFAULT symbol.

To enable or disable listed code selections.

selections RQ variables LSCAN J SCAN ] UPC (ID=c) | ¥ Version A A

Version D(2) Version E0 Version E1 Check Digit Xmit

Number System Xmit

Version E Expand 2-Digit Addenda 5-Digit Addenda

EAN (ID = d) EAN/JAN 13 EAN/JAN 8 Check Digit Xmit 2-Digit Addenda 5-Digit Addenda UPC & EAN ib Enable Addenda Req'd / MSI (ID=g) 1¥ Enable “Yes/No Minimum Length "04-MAX Maximum Length = MIN-48° Plessey (ID=n) WV Enable “Yes/No Minimum Length “O4-MAX Maximum Length ok : AMES (ID = k) Ni Enable “Yes/No Minimum Length (3) OL-MAX Maximum Length a NOTES

(1) * Designates DEFAULT selections. (2) For Potential Expansion Only, UPC-D is not currently read. (3) The DEFAULT Minimum Length for these codes is 4 characters.

Page 6 read from a scan by OCR; it may hold reading errors

AUXILIARY SCANTEAM 1200, 1100 Series PORT Information and Examples PREAMBLE/POSTAMBLE

Preambles and Postambles are characters added by the units to transmitted Aux Port data records. These characters should be sent by the Aux Port to the terminals. Use the Hex-ASCII table below to find the alpha-numeric code to be used for programming a particular Preamble or Postamble.

Programming Example: To program a horizontal TAB Postamble Scan: Enter, IV, E, 0, 9, EXIT.

HEX, ASCII CHART

NUL 00 DLE 10 SP 20 0 30 @ 40 P 50 + 60 Pp 70 SOH 01 pei 11 ! 24 1 31 A 4 Q 51 a 61 q 71 STX 02 pc2 12 "22 2 32 B42 R 52 b 62 r 72 ETX 03 Dc3 13 # 23 3 33 c 4&3 Ss 53 c 63 s 73 EOT 04 Des 14 $ 24 4 34 D 44 T 54 d 64 t 74 ENQ 05 NAK 15 % 25 5 35 E 45 U55 e 65 u 75 ACK 06 SYN 16 & 26 6 36 F 46 Vv 56 tf 66 v 76 BEL 07 ETB 17 * 27 7 37 G 47 Ww 57 g 67 w O77 BS 08 CAN 18 ( 28 8 38 H 48 xX 58 h 68 x 78 HT 09 EM 19 ) 29 9 39 1 49 Y 59 i 69 y 79 LF 0A SUB 1A * 2A : 3A J 4A Z 5A j 6A z 7A VT 0B ESC 1B + 2B > 3B K 4B [ 5B k 6B t 7B FF 0c FS 1C » 2c < 3c L 4c \ 5c 1 6c } 7c cR 0D GS 1D - 20 = 3D M 4D } 5D m 6D } 7D SO 0E RS 1E . 2E > 31 N 4 - ~ SE n 6E ~ 7E Sl OF us 1F / 2F ? 3F O 4F - oF o «6F DEL 7F INPUT MODE

NONTRANSPARENT, Data from the Aux port is treated as data from the scanner, i.e. it is sent to “Data Destination” and stored in Block Buffer (if applicable).

TRANSPARENT, Data is sent only to the Host Port and is not saved in Block Buffer if enabled.

12

Welch Allyn WA

BSCAN | tH ENTER pSCANS UN

DEFAULT

MM EXIT

COMMUNICATIONS |

SCANTEAM 1200, 1100 Series Programming Menu USE THIS PAGE

@ To select the pre-programmed asterisked (*) values by scanning DEFAULT symbol.

@ To program Host and Terminal Port communications.

BSCAN TA SCANS prone, - selections Qs variables

Terminal ID | 3 Unassigned Assigned

Protocol WA Network (1) ACK/NAK

Framed? (If Yes) Validation Mode

Validation Delay

Block

XON/XOFF

Block Checking 2 Serial Timeout (4) Sc f) Serial Delay 9 Baud Rate im 150 fA. 300 So 600 ; Ce 1200 2400 4800 9600 19200 / 38400 2 Number of See ee eae Data Bits er: BS Parity = Mark A Space & Even c Odd o Configuration = ME RS2320 x RS422 Bo Preamble (6) "ir Clear oR STX & | Code ID ay : ASCII = DE7E Time Stamp a : Date Stamp (3) oS Postamble NUL Clear a ETX BO CR c LF a Lo ASCII e Oe Time Stamp £ a “DateStamp@) Date Form (3) MM/DD/YY ee DD/MM/YY 3B L Ahearn & Soper (5) _X%__Disable x : 1180 Mode Enable ge NOTES

(1) Selecting “WA Network™ requires prior assignment of a Terminal ID in the range of 01-31. Once "WA Network” is selected only the following communications options can be altered: Date Form. Code ID, Data Destination ("To Display” only). Beep Out Port 2 and Fixed Message Length. NOTE: the unit must be configured (via jumper) in the RS232/485 mode.

{2) * Designates DEFAULT selections.

(3) Not applicable to the 1100.

(4) Starting with 1100 Level B/D, 1200 Level B/F. (5) 1200 Model 25 only.

(6) 1200 Model 25 Default is ‘Clear’.

(Sa)

Page 7 read from a scan by OCR; it may hold reading errors

COMMUNICATIONS |

SCANTEAM 1200, 1100 Series Information and Examples

Terminal 1D, when enabled permits an identifying number, called the Terminal ID, to be assigned to all data transmissions which originate from the terminal. Any value between 001-999 may be selected. When configured for Welch Allyn Network any values between 001 and 031 may be specified.

Protocol, This menu selection is used to configure the communications protocol between the Terminal and the Host.

Welch Allyn Net, When the selection ‘Welch Allyn Net’ is enabled (Yes), the terminal will operate in multidrop mode. Terminal ID’s between (001 and 031) are permitted. If no Protocol selection is specified, the terminal will default to standalone operation.

ACK/NAK, ACK/NAK protocol allows both the Host and the Terminal(s) to perform basic ACK/NAK format parity checks on all incoming messages.

Framed, when enabled, each ACK and NAK will be ‘framed’ by the terminal Preamble and Postamble which has been programmed by the user.

Validation Mode, when enabied, a validation character is substituted for the ACK/NAK response. the validation character (1B Hex) replaces the ACK, and the character (7F Hex) replaces the NAK.

Validation Delay, when this selection is enabled, the terminal may be programmed to wait from 00 to 99 seconds for validation from the host device.

Block Mode Operation, when Block Mode is enabled, each data entry (keyboard or scanned) is stored in a message buffer as a ‘block’ of data, and is not transmitted until the SEND BLOCK DATA bar code is scanned by the operator.

XON/XOFF, Can be used only in Standalone Mode. When XON/XOFF is enabled, the command “DC1” from the host to the terminal will initiate communication; the command “DC3” will stop data transmissions.

Block Checking, When enabled, a Block Check Character (BCC) is included in each data trans-mission to and from the terminal. The BCC is the “Exclusive Or” of all characters in the message, excluding the Preamble and Postamble.

Preambles, when enabled, one or more characters are transmitted as a header immediately pre-ceeding scanned bar code data or data entered from the keyboard. Up to twelve (12) preambles can be selected and will be transmitted in the order in which they are made.

Postambles, Postambles are programmable data identifiers which follow the bar code or keyboard messages. Up to twelve (12) postambles can be programmed.

PREAMBLE/POSTAMBLE

Preambles and Postambles are characters added to operator entered data. These characters are sent with the data to the Data Destination. Use the Hex-ASCII table below to find the alpha-numeric code to be used for programming a particular Preamble or Postamble.

Programming Example: To program a horizontal TAB Postamble Scan: Enter, VII, E, 0, 9, EXIT.

HEX, ASCII CHART

NUL 00 DLE 10 SP 20 0 30 @ 40 P 50 + 60 Pp 70 SOH 01 pci 11 ! 24 1°31 A 4 Q 51 a 61 q ral STX 02 pc2 12 "22 2 32 B42 R 52 b 62 r 72 ETX 03 DC3 13 # 23 3 33 Cc 43 Ss 53 c 63 s 73 EOT 04 Deca 14 $ 24 4 34 D 44 T 54 d 64 t 74 ENQ 05 NAK 15 % 25 5 35 E 45 U 55 e 65 u 75 ACK 06 SYN 16 & 26 6 36 F 46 v.56 f 66 v 76 BEL 07 ETB 17 ’ 27 7 37 G 47 Ww 57 g 6&7 w oOo? BS 08 CAN 18 (| 28 8 38 H 48 x 58 h 68 x 78 HT 09 EM 19 ) 29 9 39 1 49 Y 59 i 69 y 79 LF OA SUB 1A * 2A : 3A J 4A Z 5A j 6A z 7A VT OB ESC 1B + 2B ; «3B K 4B { 5B k 68 t 78 FF oc FS 1C » 2c < 3c L 4c \ 5c 1 6c | 7c CR oD GS 1D - 2D = 3D M 4D ] 5D m 6D } 7D SO 0E RS 1€ . 2E > 361 N 4E ~ SE n 6E ~ 7E St OF us 1F 1 2F 2? 3F O 4F - ° DE

4

Welch Allyn WA

BSCAN |

SCANS |

AUXILIARY PORT SCANTEAM 1200, 1100 Series Programming Menu

USE THIS PAGE @ To select the pre-programmed asterisked (*) values by scanning DEFAULT symbol.

B® To program Auxiliary Port communications parameters and protocol. Mi Not applicable to the 1100.

EQN variables L SCAN I SCAN ] a ciaeansaeansseamarenssesmsesrsareemereest

ML = NTER

Baud Rate

EFAULT

Parity

Word Length

Number of Stop Bits Preamble v Clear STX Other ASCII / c 00-75 Postamble Ni Clear ETX 8 CR Cc LF DO: Other ASCII E O0-7F Input Mode YUL Non-Transparent Ay Transparent 3.

NOTES only on the “Model 1200 Terminal”.

(1) * Designates DEFAULT settings. (2) This menu page programs the characteristics of the Auxiliary Serial Port available

XIT 13

Page 8 read from a scan by OCR; it may hold reading errors

NETWORK SCANTEAM 1200, 1100 Series CONTROLLER Information and Examples

For additional information regarding the use of the Welch Allyn 1500 and 1550

Network Controllers refer to the publications listed below.

14

SCANTEAM 1500 Programmable Network Controller

Publication Nos.: 11202733 REV. B 11203466-01 Lev 1

SCANTEAM 1550 Network Controller Publication No: 11204189-01

DISK: 31202077-04

AVAILABLE FROM:

Welch Allyn

Data Collection Division

Jordan Road

Skaneateles Falls, NY 13153-0187 Telephone (315) 685-8945

Welch Allyn WA

BSCAN | ENTER Hn DEFAULT

LM EXIT

SCANTEAM 1200, 1100 Series TERMINAL Programming Menu CHARACTERISTIC USE THIS PAGE

@ To select the pre-programmed asterisked (*) values by scanning DEFAULT symbol. @ To set beeper volume and tone.

@ To configure laser scanning.

@ To enable time display and select time format.

@ To set time and date.

@ To obtain a status report.

selections EQNS variables L SCAN J SCAN |]

| Off/Low/Mid/High

Beeper Volume (4)

Beeper Tone (2)(4)

Laser-Scan

Voting

Laser-Scan

Timeout

Output Buffer

Time Display Enable

Time Format 12 Hr Format 24 Hr Format

Time Set (4) _ AM PM Hours (3) Mins Secs

Date Set (4) = p< Month Day Year

Status Report _ & Full Report Network Controller 8 Firmware Level = € Buffer Space (4) Available

NOTES:

(1) * Designates DEFAULT selections. (2) The DEFAULT Tone is No. 3.

(3) The AM/PM option and the hour parameters 01-12 are only selectable when the 12 hr. format is enabled.

(4) Not applicable to the 1100.

Page 9 read from a scan by OCR; it may hold reading errors

TERMINAL

CHARACTERISTICS

SCANTEAM 1200, 1100 Series Information and Examples

LASER SCAN VOTING

YES, Units will compare three (3) consecutive laser scans which result in valid decodes against each other. All three must be the same for a good read to occur.

NO, Only one (1) laser scan resulting in a valid decode is needed for a: good read.

LASER SCAN TIMEOUT

YES, After approximately six (6) seconds the units will turn off any laser scanners connected to either scanner port.

NO, Power to device is never turned off.

OUTPUT BUFFER

YES, When Output Buffer is enabled, bar code data is queued in the output buffer. Scanning may continue until memory is filled (standard 1200 memory 8K, expandable to 72K)

NO, When Output Buffer is not enabled, only one (1) scanned bar code entry will be stored in the buffer. It will remain in the buffer until that data has been transmitted and the buffer is cleared. After data has been transmitted, scanning may resume.

TIME DISPLAY ENABLE ‘YES’, When selected, hours (HH) and minutes (MM) will appear right justified on the display. Format is HH:MM. Time is updated every minute.

STATUS REPORTING

FULL REPORT, This selection sends to the designated “Data Destination” (See Communications Il menu page) all options on the Programming Menu. Refer to System Guide for individual status information.

NETWORK CONTROLLER, This report selection is available only when the 1200/1100 terminal is connected to a Welch Allyn 1500 Programmable Network Controller. When this report option is enabled, the Controller will transmit its programmed status out the computer port.

FIRMWARE LEVEL, When this report is requested, the terminal will send the level of resident firmware in the form (Part No., Level X) to the specified “Data Destination”.

BUFFER SPACE AVAILABLE, When this report is requested, the terminal will send the amount of available buffer space to the selected “Data Destination”.

Welch Allyn WA

Tm

ENTER

BSCAN | DEFAULT

I!

NETWORK

CONTROLLER SCANTEAM 1200, 1100 Series

Programming Menu

USE THIS PAGE @ To program a Welch Allyn Scanteam 1500 Network Controller.

selections QI variables Baud Rate

BSCAN TE SCANS

Mark Space Even Odd RS422 RS232C Unassigned Assigned STX Controller ID Code ID SOH None Postamble vi _ETX CR LF KT ACK/NAK Protocol Ng Enable nframe (if enabled) Yes/No Disabled go Intercharacter Vili No A Delay Yes 8. Go Live Mode 1X Enable A Disable 8

Parity

1/0 Format

Controller ID

Preamble

NOTE

This menu page allows programming the characteristics at the Host Port of Welch Allyn's Network Controller. A failure to beep indicates commands the Controller does not recog-nize within it's allowed menu sequence. In addition, “DEFAULT”. “Escape” and “Status” have no meaning to the Network Controller; a status report from the Network Controller may be initiated using commands on TERMINAL CHARACTERISTICS menu page.

15

Page 10 read from a scan by OCR; it may hold reading errors

MSR SCANTEAM 1200, 1100 Series MAGNETIC STRIPE READER _ Information and Examples

MAGNETIC STRIPE READER

The SCANTEAM 1200/1100 accepts undecoded digital signals from magnetic stripe readers recorded in a format consistent with ANSI! Specifications X4.16 - 1983.

These specifications can be obtained by contacting:

American National Standard Institute Inc. 1430 Broadway New York, New York 10018

16

Welch Allyn WA scaNTEAM 1200, 1100 Series SYSTEM

Programming Menu USE THIS PAGE @ Asageneral overview of the programming menu. The programming menu consists of two basic components as shown below.

Welch Allyn WA. CODE SELECTION I! BAR CODE CHART SSCANTEAM 1200, 1100 Series ‘SCANTEAM 1200, 1100 Series Fer mim guetovogetingeorccnane am Programming Menu = roman numerals. letters sights others i === == ve) = Te (NO) HAM al cM) Suis eres wel WO) ae) BRM AEA ~ TINT) 6 oe Nt GEOINT = UMMM ve P 5 SEAOLL KOMT (HWM UY vin ¢ 6 SOROLL LES? Te seauins HUGH») UY MEY IRIE = x 3 $ oreauLt im = oun MENU PAGE BAR CODE CHART

MENU PAGE

@ Each menu page represents one section of the programming menu. Use individual menu pages in combination with the adjoining bar code chart to program the decoder.

USE THIS PAGE, as a summary of the programming options of each menu page.

ENTER, Each menu page has its own unique ENTER bar code; scan this bar code to activate desired menu page.

DEFAULT, Most menu pages have a DEFAULT bar code which allows the user to independently default menu pages to astericked (*) values without affecting, in any way, the rest of the programming menu. Default values can be easily selected from desired menu. pages by scanning the bar code sequence ENTER, DEFAULT, EXIT. Individual defaults for a specific selection can be made by scanning ENTER, ROMAN NUMERAL, DEFAULT, EXIT.

EXIT, To move from one menu page to another or when all programming is complete, scan the EXIT bar code. This bar code must be scanned to end selection on each menu page before starting selection of other menu pages.

SELECTION /VARIABLES, Lists all of the options available on each menu page. Following each option are symbols in shaded areas. These symbols correspond to bar codes on adjoining bar code chart.

NOTES, are provided to call-out any unusual situations.and/or refer you to necessary information or examples elsewhere in the menu or manual.

MENU PAGE FACING (Not Shown)

@ Use this side to supplement or clarify the material presented on the front of each menu page. The information and examples found here are specific to the individual menu pages and contain, in some cases, charts or diagrams that must be used in order to determine programming sequence.

BLOCK MODE CONTROL w Use these bar codes to transmit or clear the Block Buffer.

BAR CODE CHART

@ The bar codes on this page are assigned to a ROMAN NUMERAL, DIGIT, LETTER OR YES/NO symbol. These bar codes correspond to symbols in shaded areas on adjoining menu pages and are scanned in various combinations to enter programming sequences to decoder. Bar codes on this page are meaningless unless an ENTER bar code from one of the individual menu pages is scanned. When an ENTER bar code is scanned, the bar code chart becomes specific to that individual menu page and remains so until the EXIT bar code is scanned.

ESCAPE

@ Use this bar code to cancel current programming sequence. All parameters remain as they were. Scan ESCAPE.

STATUS

@ Use this bar code to get status of individual selections on pages. Status is always sent to “Data Destination” selection made on Communication Characteristics page. Scan: ENTER, ROMAN NUMERAL, STATUS, EXIT. Should a page of status information be desirable, Scan: ENTER, STATUS, EXIT.

GUIDE