The text of a manual · part 3 of 6
Quick Check 2D Print Quality Assessment User's Guide: Introduction, pages 13 to 20
Pages 13 to 20 of 36, from Quick Check 2D Print Quality Assessment User's Guide
The original document is the PDF (512 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the HHP IT4410
Page 13
F otherwise.
In Screening modes, this parameter is reported as "Useful Row Height is Too Short (1.5X)" when that is the case. {7} lists the Data Safety Margin, the ratio of the unused error correction words to the recommended (!) number of such words. As such, Data Safety Margin can exceed 100%, when the ECL is higher than the minimum recommended, or be limited to 50% or lower, even with perfect printing, when the ECL is below minimum. The grade is assigned as:
A if Safety Margin >= 62%, else
B if Safety Margin >= 50%, else
C if Safety Margin >= 37%, else
D if Safety Margin >= 25%, else
F otherwise.
In Screening modes, this parameter is reported as "Low Data Safety Margin (44%)" when that is the case. {8} lists the Edge Accuracy measured in the Start or Stop patterns. The grade is assigned as:
A if Edge Accuracy >= 62%, else
B if Edge Accuracy >= 50%, else
C if Edge Accuracy >= 37%, else
D if Edge Accuracy >= 25%, else
F otherwise.
In Screening modes, this parameter is reported as "Poor Edge Accuracy (59%)" when that is the case. {9} lists the Print Growth measured in the Start or Stop patterns (actually the growth of the dark modules or "bars"). The grade is assigned as:
A if Print Growth is between +/- 20%, else
B if Print Growth is between +/- 30%, else
C if Print Growth is between +/- 40%, else
D if Print Growth is between +/- 50%, else
F otherwise.
In Screening modes, this parameter is reported as "Excessive Print Growth (33%)" or "Excessive Print Shrinkage (-43%)" when those are the cases.
1-9
Page 14
In rare instances where neither a valid Start nor Stop pattern is measurable, yet the symbol is somehow read, lines {8} and {9} are replaced by a message to that effect. The message is either:
"[F] < Start/Stop Decode Fails" in a Full Report or "Start/Stop Characters are Bad" in a Screening mode. In Screening modes, it often occurs that none of the parameters are below the Minimum Acceptable grade. In this case, the final PQA line becomes:
"All Measurements within range".
MicroPDF417 The Full Report from a typical scan looks like the following (where line numbers have been added in curly brackets): {1} This is a typical Micro PDF417 symbol {2} >>> PQA from HHP <<< {3} MICROPDF: 15 rows x 3 cols, 24 data & 21 chks {4} X roughly = 0.015" {5} [A] < Row Height = 1.8 X {6} [A] < Data Safety Margin = 100% (0 Erasures & 0 Errors) {7} [A] < Edge Accuracy = 70% {8} [A] < Print Growth = +4% of X where: {1} is the Encoded Message. {2} is the Banner heading. {3} identifies the Symbology, MICROPDF (or one of its derivatives: COMPOSITE-A, COMPOSITE-B, or TLC39), and lists other characteristics of this symbol: the Height & Width, and the numbers of Data and Check, or Error Correction, characters. {4} presents an approximate X-dimension.
Note: The reported X-dimensions are approximate and based upon use of the IT4410LR at optimum focus (See "Reading Techniques" on page 1-3). If you use other HHP imagers, the X-dimension will vary. Please contact HHP Application Support for additional information. {5} lists the average Row Height – assigning the grades as:
A if Row Height >= 1.5 X,
F otherwise.
1 - 10
Page 15
{6} lists the Data Safety Margin. Because MicroPDF's error correction level is fixed, this parameter is just the "Unused Error Correction" and always between 0 and 100%. {7} lists the Edge Accuracy – measured in multiple scans through the Row Address Patterns. {8} lists the Print Growth – measured within the Row Address Patterns.
2D Matrix This section describes 2D PQA outputs for Aztec Code, Data Matrix, QR Code, and MaxiCode.
Aztec Code The Full Report from a typical scan looks like the following (where line numbers have been added in curly brackets): {1} This is a representative Aztec Code symbol {2} >>> PQA from HHP <<< {3} AZTEC CODE: 3 layers (Compact) => 23x23 modules {4} Data Field: 29 data & 22 chks in GF(256), 0 Erasures & 0 Errors {5} X roughly = 0.021" {6} [A] < Core Symbol: 0 errors {7} [A] < Data Safety Margin = 146% {8} [A] < Horizontal Print Growth = +1% of X {9} [A] < Vertical Print Growth = +1% of X
{1} is the Encoded Message. {2} is the Banner heading. {3} identifies the Symbology (AZTEC CODE) and lists the symbol's size and format. {4} lists the numbers of Data and Check Words, as well as the Error Correction used. {5} presents an approximate X-dimension.
Note: The reported X-dimensions are approximate and based upon use of the IT4410LR at optimum focus (See "Reading Techniques" on page 1-3). If you use other HHP imagers, the X-dimension will vary. Please contact HHP Application Support for additional information.
1 - 11
Page 16
{6} lists the number of Module Errors in the central Core Symbol, which consists of the Finder bullseye, four Orientation Clusters at its corners, and the Mode Message along its perimeter. The grade is assigned as:
A if there are 0 (zero) errors,
B if there is 1 error,
C if there are 2 errors,
D if there are 3 errors, or
F if there are 4 or more errors.
In Screening modes, this parameter is reported as "Too many Code Symbol Errors (3)" when that is the case. {7} lists the Data Safety Margin. In Aztec Code symbols, the recommended number of error correction words is a minimum that is generally exceeded because any excess codeword capacity is filled with extra check words. Thus this parameter often exceeds 100%, but it also can be forced to much higher or lower levels by user options. {8} and {9} list the Horizontal & Vertical Print Growths respectively. When one direction's growth is substantially larger than the other, excessive bar dragging in the direction of label travel is indicated and should be fixed. When both directions have excessive growth, then either (a) adjustment of the print process or (b) undercutting of the original bar code symbol graphic is recommended.
Data Matrix The Full Report from a typical scan looks like the following (where line numbers have been added in curly brackets): {1} This is a representative Data Matrix symbol {2} >>> PQA from HHP <<< {3} DATA MATRIX ECC200: 24 x 24 modules in size {4} Data Field: 36 data & 24 chks in 1 block(s) of GF(256) {5} X roughly = 0.025" {6} [A] < Fixed Patterns: 0 module errors {7} [A] < Data Safety Margin = 100% {8} [A] < Horizontal Print Growth = +10% of X {9} [A] < Vertical Print Growth = +12% of X
{1} is the Encoded Message. {2} is the Banner heading.
1 - 12
Page 17
{3} identifies the Symbology (DATA MATRIX) and lists the symbol's ECC and Size. {4} lists the numbers of Data and Check Words, as well as the Error Correction used. {5} presents an approximate X-dimension.
Note: The reported X-dimensions are approximate and based upon use of the IT4410LR at optimum focus (See "Reading Techniques" on page 1-3). If you use other HHP imagers, the X-dimension will vary. Please contact HHP Application Support for additional information. {6} lists the number of Module Errors in the Fixed Patterns, which consist of the Finder "L" and Clocking tracks around the perimeter of the symbol, their adjacent quiet zones, and any interior Alignment Patterns in larger ECC200 symbols. In Screening modes, this parameter is reported as "Too many Fixed Pattern Errors (3)" when that is the case. {7} lists the Data Safety Margin. This parameter is measured and reported only for ECC200 symbols. These symbols have a fixed level of error correction. There is no equivalent parameter for the convolutional error encoding used in older versions of Data Matrix. This parameter is just the "Unused Error Correction" and always between 0 and 100%. {8} and {9} list the Horizontal & Vertical Print Growths respectively.
QR Code The Full Report from a typical scan looks like the following (where line numbers have been added in curly brackets): {1} This is a representative QR Code symbol {2} >>> PQA from HHP <<< {3} QR CODE: Model 2 Version 3 (29 x 29 modules) {4} Mask Pattern Reference #3, Error Correction Level "M" {5} Data Field: 44 data & 26 checks in 1 block(s) of GF(256) {6} X roughly = 0.025" {7} [A] < Data Safety Margin = 100% {8} [A] < Horizontal Print Growth = +20% of X {9} [A] < Vertical Print Growth = +17% of X
1 - 13
Page 18
{1} is the Encoded Message. {2} is the Banner heading. {3} identifies the Symbology (QR CODE) and lists the symbol's model, version and size. {4} lists this symbol's Mask Pattern and Error Correction Level. {5} lists the numbers of Data and Check Words and their arrangement into blocks. {6} presents an approximate X-dimension.
Note: The reported X-dimensions are approximate and based upon use of the IT4410LR at optimum focus (See "Reading Techniques" on page 1-3). If you use other HHP imagers, the X-dimension will vary. Please contact HHP Application Support for additional information. {7} lists the Data Safety Margin. "M" is the recommended Error Correction Level for QR Code, so symbols encoded at "H" or "Q" will typically have Safety Margins exceeding 100% while those encoded at "L" are limited to values below 50%. {8} and {9} list the Horizontal & Vertical Print Growths respectively.
MaxiCode The Full Report from a typical scan looks like the following (where line numbers have been added in curly brackets): {1} This is a representative Maxicode symbol {2} >>> PQA from HHP <<< {3} MAXICODE: Mode 4 {4} X roughly = 0.043" {5} [A] < Data Safety Margin = 100% {6} [A] < Horizontal Print Growth = +2% of X {7} [A] < Vertical Print Growth = -1% of X
{1} is the Encoded Message. {2} is the Banner heading. {3} identifies the Symbology (MAXICODE) and lists the symbol's Mode. {4} presents an approximate X-dimension.
Note: The reported X-dimensions are approximate and based upon use of the IT4410LR at optimum focus (See "Reading Techniques" on page 1-3). If
1 - 14
Page 19
you use other HHP imagers, the X-dimension will vary. Please contact HHP Application Support for additional information. {5} lists the Data Safety Margin. Because the Error Correction level for MaxiCode is fixed for each Mode, this parameter is just the "Unused Error Correction" and always between 0 and 100%. {6} and {7} list the Horizontal & Vertical Print Growths respectively.
Postal (Height-Modulated) Bar Code Symbologies This section describes the height-modulated 2-state symbologies, POSTNET and PLANET Code, used in the United States, as well as the 4-state symbologies used in England, the Netherlands ("KIX"), Canada, Japan, and Australia. All dimensions, where listed, are in inches for 2-state symbols and in millimeters for 4-state symbols.
POSTNET and PLANET CODE The Full Report from a typical scan looks like the following (where line numbers have been added in curly brackets): {1} 51591 {2} >>> PQA from HHP <<< {3} POSTNET: 32 Bars, nominally from 01.30 to 01.56 in. in Width {4} Bar Sequence: 10101000011010101010000011101001 {5} [F] (Hi) < Tall Bar Heights: 0.155 in. {6} [F] (Hi) < Short Bar Heights: 0.081 in. {7} [A] (Ok) < Bar Widths = 0.022 in. {8} [A] (Ok) < Inter-Bar Gaps = 0.023 in.
{1} is the Encoded Message. {2} is the Banner heading. {3} identifies the Symbology, (POSTNET or PLANET Code), and lists also the symbol's size and allowed range of measured width. {4} lists the Bar Sequence, "1" representing a tall bar and "0" representing a short one. {5} lists the Average Height of the tall bars, specified to fall within 0.115 to 0.125 in. The grades are assigned as:
A if within the middle 67% of the specified tolerances, else
1 - 15
Page 20
B if within the specified tolerances, else
C if within a range 25% wider(!) than the specified tolerances, else
D if within a range 50% wider(!) than the specified tolerances, else
F otherwise.
Note: These forgiving grade assignments, employed throughout the postal symbologies, reflect what are generally tight and unforgiving print specifications. In Screening modes, this parameter is reported as ""Tall" Bars are too Short (or Long) (0.xxx in.)" when that is the case. {6} lists the Average Height of the short bars, specified to fall within 0.040 to 0.060 in. In Screening modes, this parameter is reported as ""Short" Bars are too Short (or Long) (0.xxx in.)" when that is the case. {7} lists the Average Width of the bars, specified to fall within 0.015 to 0.025 in. In Screening modes, this parameter is reported as "Bars are too Narrow (or Wide) (0.xxx in.)" when that is the case. {8} lists the Average Space Width between bars, specified to fall within 0.012 to 0.040 in. In Screening modes, this parameter is reported as "Spaces are too Narrow (or Wide) (0.xxx in.)" when that is the case.
4-STATE Codes The Full Report from a typical scan looks like the following (where line numbers have been added in curly brackets): {1} B15AJ6T {2} >>> PQA from HHP <<< {3} 4-STATE(British): 34 Bars, nominally from 38.5 to 42.3 mm. in Width {4} Bar Sequence: ADHTATDAHDDAADADAADTHTADHHDATHTADH {5} [A] (Ok) < "Tall" Bar Extensions: 2.79 mm. from center {6} [F] (Hi) < "Short" Bar Extensions: 1.00 mm. from center {7} [B] (Hi) < Bar Widths = 0.60 mm. {8} [A] (Ok) < Inter-Bar Gaps = 0.59 mm.
1 - 16